{"id":{"repo_id":"sask","oai_identifier":"oai:harvest.usask.ca:10388/16042"},"canonical_url":"https://search.ndltd.org/etd/sask/oai:harvest.usask.ca:10388/16042","repository":{"repo_id":"sask","name":"University of Saskatchewan","base_url":"https://harvest.usask.ca/server/oai/request"},"display":{"title":"Improvement of Synchrotron Radiation Propagation-based Imaging Computed Tomography for Tissue-scaffold Visualization","abstract":"Scaffolds-based tissue engineering (TE) aims to create substitutes for repairing damaged tissues/organs by means of scaffolds, which are of a three-dimensional (3D) structure made from biomaterials to support tissue regeneration. Scaffold visualization is important to the success of scaffolds-based TE studies, for discovering the scaffold-supported tissue regeneration and further optimizing the scaffold design. This becomes critical in both in vitro and in vivo longitudinal studies, particularly with the advance towards human studies where traditional invasive/destructive imaging methods have to be relinquished. Instead, non-invasive imaging techniques must be employed for visualizing and examining scaffolds at intermediate stages during the repair process. For this, synchrotron radiation propagation-based imaging computed tomography (SR-PBI-CT) holds promising due to its distinct advantages including high resolution, sufficient contrast, and relatively fast scanning. Notably, SR-PBI-CT is currently facing some challenges specific to scaffold visualization applications. Among these, two key issues urgently need to be resolved. The first issue is the ring artifacts in SR-PBI-CT images, which presents a significant challenge in post image processing and data analysis, particularly for low-density samples, such as hydrogel tissue-scaffolds, which have been widely used in tissue regeneration nowadays, and soft tissues. The second issue is the trade-off of imaging quality versus radiation dose (received by the subject or host being imaged), which is critical to the longitudinal studies on live animals or eventually on clinical applications.","abstract_html":"Scaffolds-based tissue engineering (TE) aims to create substitutes for repairing damaged tissues/organs by means of scaffolds, which are of a three-dimensional (3D) structure made from biomaterials to support tissue regeneration. Scaffold visualization is important to the success of scaffolds-based TE studies, for discovering the scaffold-supported tissue regeneration and further optimizing the scaffold design. This becomes critical in both in vitro and in vivo longitudinal studies, particularly with the advance towards human studies where traditional invasive/destructive imaging methods have to be relinquished. Instead, non-invasive imaging techniques must be employed for visualizing and examining scaffolds at intermediate stages during the repair process. For this, synchrotron radiation propagation-based imaging computed tomography (SR-PBI-CT) holds promising due to its distinct advantages including high resolution, sufficient contrast, and relatively fast scanning. Notably, SR-PBI-CT is currently facing some challenges specific to scaffold visualization applications. Among these, two key issues urgently need to be resolved. The first issue is the ring artifacts in SR-PBI-CT images, which presents a significant challenge in post image processing and data analysis, particularly for low-density samples, such as hydrogel tissue-scaffolds, which have been widely used in tissue regeneration nowadays, and soft tissues. The second issue is the trade-off of imaging quality versus radiation dose (received by the subject or host being imaged), which is critical to the longitudinal studies on live animals or eventually on clinical applications.","abstract_has_math":false,"creators":["Duan, Xiaoman"],"institution":"University of Saskatchewan","degree_name":"Doctor of Philosophy (Ph.D.)","degree_level":"Doctoral","degree_discipline":"Biological Engineering","degree_department":"Biomedical Engineering","school":null,"contributors":[],"advisors":["Chen, Daniel","Zhu, Ning"],"committee_chairs":[],"committee_members":["Zhang, Chris","Stavness, Ian","Wu, Fangxiang","Chapman, Dean"],"year":2024,"date_issued":"2024-09-17","date_published":"2024-09-17","updated_at":"2026-11-19T10:01:12Z","subjects":["Tissue engineering","Synchrotron radiation propagation-based imaging computed tomography","Low radiation dose","Image quality analysis"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000-0003-1221-1609"],"render_values":[{"text":"0000-0003-1221-1609","href":"https://orcid.org/0000-0003-1221-1609","code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/10388/16042","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10388/16042","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":"embargoed","embargo_until":"2026-09-17","access_note":null},"source_record":{"url":"https://harvest.usask.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aharvest.usask.ca%3A10388%2F16042","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Chen, Daniel","Zhu, Ning"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Zhang, Chris","Stavness, Ian","Wu, Fangxiang","Chapman, Dean"]},{"key":"dc:creator","label":"Author","values":["Duan, Xiaoman"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000-0003-1221-1609"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-09-17T16:50:13Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2024"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-08"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2026-09-17"]},{"key":"dc:date.issued","label":"Date","values":["2024-09-17"]},{"key":"dc:date.liftdate","label":"Dc Date Liftdate","values":["2026-09-17"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2024"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2024-09-17T16:50:13Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_department","label":"Department","values":["Biomedical Engineering"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biological Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (Ph.D.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Saskatchewan"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Tissue engineering","Synchrotron radiation propagation-based imaging computed tomography","Low radiation dose","Image quality analysis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10388/16042"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Scaffolds-based tissue engineering (TE) aims to create substitutes for repairing damaged tissues/organs by means of scaffolds, which are of a three-dimensional (3D) structure made from biomaterials to support tissue regeneration. Scaffold visualization is important to the success of scaffolds-based TE studies, for discovering the scaffold-supported tissue regeneration and further optimizing the scaffold design. This becomes critical in both in vitro and in vivo longitudinal studies, particularly with the advance towards human studies where traditional invasive/destructive imaging methods have to be relinquished. Instead, non-invasive imaging techniques must be employed for visualizing and examining scaffolds at intermediate stages during the repair process. For this, synchrotron radiation propagation-based imaging computed tomography (SR-PBI-CT) holds promising due to its distinct advantages including high resolution, sufficient contrast, and relatively fast scanning. Notably, SR-PBI-CT is currently facing some challenges specific to scaffold visualization applications. Among these, two key issues urgently need to be resolved. The first issue is the ring artifacts in SR-PBI-CT images, which presents a significant challenge in post image processing and data analysis, particularly for low-density samples, such as hydrogel tissue-scaffolds, which have been widely used in tissue regeneration nowadays, and soft tissues. The second issue is the trade-off of imaging quality versus radiation dose (received by the subject or host being imaged), which is critical to the longitudinal studies on live animals or eventually on clinical applications."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Improvement of Synchrotron Radiation Propagation-based Imaging Computed Tomography for Tissue-scaffold Visualization"]},{"key":"others:access_status","label":"Others Access Status","values":["embargo"]}]}],"canonical_facts":{"dc:contributor.advisor":["Chen, Daniel","Zhu, Ning"],"dc:contributor.committeemember":["Zhang, Chris","Stavness, Ian","Wu, Fangxiang","Chapman, Dean"],"dc:creator":["Duan, Xiaoman"],"dc:date.accessioned":["2024-09-17T16:50:13Z"],"dc:date.copyright":["2024"],"dc:date.created":["2024-08"],"dc:date.embargo":["2026-09-17"],"dc:date.issued":["2024-09-17"],"dc:date.liftdate":["2026-09-17"],"dc:date.submitted":["August 2024"],"dc:date.updated":["2024-09-17T16:50:13Z"],"dc:description.abstract":["Scaffolds-based tissue engineering (TE) aims to create substitutes for repairing damaged tissues/organs by means of scaffolds, which are of a three-dimensional (3D) structure made from biomaterials to support tissue regeneration. Scaffold visualization is important to the success of scaffolds-based TE studies, for discovering the scaffold-supported tissue regeneration and further optimizing the scaffold design. This becomes critical in both in vitro and in vivo longitudinal studies, particularly with the advance towards human studies where traditional invasive/destructive imaging methods have to be relinquished. Instead, non-invasive imaging techniques must be employed for visualizing and examining scaffolds at intermediate stages during the repair process. For this, synchrotron radiation propagation-based imaging computed tomography (SR-PBI-CT) holds promising due to its distinct advantages including high resolution, sufficient contrast, and relatively fast scanning. Notably, SR-PBI-CT is currently facing some challenges specific to scaffold visualization applications. Among these, two key issues urgently need to be resolved. The first issue is the ring artifacts in SR-PBI-CT images, which presents a significant challenge in post image processing and data analysis, particularly for low-density samples, such as hydrogel tissue-scaffolds, which have been widely used in tissue regeneration nowadays, and soft tissues. The second issue is the trade-off of imaging quality versus radiation dose (received by the subject or host being imaged), which is critical to the longitudinal studies on live animals or eventually on clinical applications."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/10388/16042"],"dc:language.iso":["en"],"dc:subject":["Tissue engineering","Synchrotron radiation propagation-based imaging computed tomography","Low radiation dose","Image quality analysis"],"dc:title":["Improvement of Synchrotron Radiation Propagation-based Imaging Computed Tomography for Tissue-scaffold Visualization"],"dc:type":["Thesis","text"],"others:access_status":["embargo"],"person:identifier.orcid":["0000-0003-1221-1609"],"thesis:degree_department":["Biomedical Engineering"],"thesis:degree_discipline":["Biological Engineering"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Doctor of Philosophy (Ph.D.)"],"thesis:institution_name":["University of Saskatchewan"]},"updated_at":"2026-11-19T10:01:12Z"}