{"id":{"repo_id":"sask","oai_identifier":"oai:harvest.usask.ca:10388/16159"},"canonical_url":"https://search.ndltd.org/etd/sask/oai:harvest.usask.ca:10388/16159","repository":{"repo_id":"sask","name":"University of Saskatchewan","base_url":"https://harvest.usask.ca/server/oai/request"},"display":{"title":"MODELING OF SHIELDED MICROSTRIP TRANSMISSION LINES","abstract":"Microstrip lines are widely used not only in microwave circuits, but also in very large scale integration (VLSI) and high frequency circuit boards. Initially microstrip lines were analyzed mainly in the frequency domain, but now time domain analysis is also becoming a subject of prime importance. Time domain analysis data is relevant in determining the behavior of many microwave and VLSI circuits. Full wave time domain analysis is usually not practical due to computer time and memory requirements. Therefor, time domain analysis is usually carried out via frequency domain analysis and the inverse Fourier transform. Frequency domain analysis can be very accurate when a stationary model for the dispersive behavior of a microstrip line is utilized. This method has been successfully employed in time domain analysis of various forms of open microstrip lines. Since most microwave integrated circuits (MIC) and VLSI packagings have closed structures, an efficient and fast time domain analysis of such structures requires a model which describes the dispersive behavior of a shielded microstrip line. However, unlike the case for an unshielded microstrip line, no dispersion model exists for the shielded microstrip line.","abstract_html":"Microstrip lines are widely used not only in microwave circuits, but also in very large scale integration (VLSI) and high frequency circuit boards. Initially microstrip lines were analyzed mainly in the frequency domain, but now time domain analysis is also becoming a subject of prime importance. Time domain analysis data is relevant in determining the behavior of many microwave and VLSI circuits. Full wave time domain analysis is usually not practical due to computer time and memory requirements. Therefor, time domain analysis is usually carried out via frequency domain analysis and the inverse Fourier transform. Frequency domain analysis can be very accurate when a stationary model for the dispersive behavior of a microstrip line is utilized. This method has been successfully employed in time domain analysis of various forms of open microstrip lines. Since most microwave integrated circuits (MIC) and VLSI packagings have closed structures, an efficient and fast time domain analysis of such structures requires a model which describes the dispersive behavior of a shielded microstrip line. However, unlike the case for an unshielded microstrip line, no dispersion model exists for the shielded microstrip line.","abstract_has_math":false,"creators":["Wells, Garnet Stuart"],"institution":"University of Saskatchewan","degree_name":"Master of Science (M.Sc.)","degree_level":"Masters","degree_discipline":null,"degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":["Pramanick, Protap"],"committee_chairs":[],"committee_members":[],"year":1996,"date_issued":"1996","date_published":"1996","updated_at":"2026-11-19T10:14:05Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10388/16159","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10388/16159","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Asask%3Aoai%3Aharvest.usask.ca%3A10388%2F16159","prefix":"oai_dc"},"source_record":{"url":"https://harvest.usask.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aharvest.usask.ca%3A10388%2F16159","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Pramanick, Protap"]},{"key":"dc:creator","label":"Author","values":["Wells, Garnet Stuart"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-10-09T22:07:53Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-10-09T22:07:53Z"]},{"key":"dc:date.issued","label":"Date","values":["1996"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["1996"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.Sc.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Saskatchewan"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10388/16159"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Microstrip lines are widely used not only in microwave circuits, but also in very large scale integration (VLSI) and high frequency circuit boards. Initially microstrip lines were analyzed mainly in the frequency domain, but now time domain analysis is also becoming a subject of prime importance. Time domain analysis data is relevant in determining the behavior of many microwave and VLSI circuits. Full wave time domain analysis is usually not practical due to computer time and memory requirements. Therefor, time domain analysis is usually carried out via frequency domain analysis and the inverse Fourier transform. Frequency domain analysis can be very accurate when a stationary model for the dispersive behavior of a microstrip line is utilized. This method has been successfully employed in time domain analysis of various forms of open microstrip lines. Since most microwave integrated circuits (MIC) and VLSI packagings have closed structures, an efficient and fast time domain analysis of such structures requires a model which describes the dispersive behavior of a shielded microstrip line. However, unlike the case for an unshielded microstrip line, no dispersion model exists for the shielded microstrip line."]},{"key":"dc:title","label":"Title","values":["MODELING OF SHIELDED MICROSTRIP TRANSMISSION LINES"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Pramanick, Protap"],"dc:creator":["Wells, Garnet Stuart"],"dc:date.accessioned":["2024-10-09T22:07:53Z"],"dc:date.available":["2024-10-09T22:07:53Z"],"dc:date.issued":["1996"],"dc:date.submitted":["1996"],"dc:description.abstract":["Microstrip lines are widely used not only in microwave circuits, but also in very large scale integration (VLSI) and high frequency circuit boards. Initially microstrip lines were analyzed mainly in the frequency domain, but now time domain analysis is also becoming a subject of prime importance. Time domain analysis data is relevant in determining the behavior of many microwave and VLSI circuits. Full wave time domain analysis is usually not practical due to computer time and memory requirements. Therefor, time domain analysis is usually carried out via frequency domain analysis and the inverse Fourier transform. Frequency domain analysis can be very accurate when a stationary model for the dispersive behavior of a microstrip line is utilized. This method has been successfully employed in time domain analysis of various forms of open microstrip lines. Since most microwave integrated circuits (MIC) and VLSI packagings have closed structures, an efficient and fast time domain analysis of such structures requires a model which describes the dispersive behavior of a shielded microstrip line. However, unlike the case for an unshielded microstrip line, no dispersion model exists for the shielded microstrip line."],"dc:identifier.uri":["https://hdl.handle.net/10388/16159"],"dc:title":["MODELING OF SHIELDED MICROSTRIP TRANSMISSION LINES"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Electrical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science (M.Sc.)"],"thesis:institution_name":["University of Saskatchewan"]},"updated_at":"2026-11-19T10:14:05Z"}