{"id":{"repo_id":"sask","oai_identifier":"oai:harvest.usask.ca:10388/16878"},"canonical_url":"https://search.ndltd.org/etd/sask/oai:harvest.usask.ca:10388/16878","repository":{"repo_id":"sask","name":"University of Saskatchewan","base_url":"https://harvest.usask.ca/server/oai/request"},"display":{"title":"Advanced Stator Inter-Turn Fault Diagnosis Methods for Line-Connected Induction Motors","abstract":"Stator inter-turn faults (SITFs) represent a significant portion of induction motor failures, potentially causing costly disruptions if undetected. Traditional fault detection methods often rely on complex feature engineering, lack generalizability, and may not be sensitive to early-stage SITFs. This research aims to develop advanced techniques for accurate, robust, early detection of SITFs, fault severity evaluation, and faulty phase identification for line-connected induction motors. A novel two-dimensional (2D) convolutional neural network (CNN)-based SITF detection technique is first proposed, where the fundamental frequency phasor magnitude (FPM) and the third harmonic frequency component (TFC) of three-phase stator currents are used as the fault detection signals. The extracted FPM and TFC signals from the three-phase currents are transformed into three-dimensional (3D) color images in a Red-Green-Blue (RGB) structure using a current-to-image transformation mechanism. The developed CNN model is validated using the experimental data of a line-connected 2.2 kW induction motor operating under healthy and various SITF conditions, and different motor loadings and unbalanced supply voltage are also considered. Both FPM and TFC exhibit almost identical precision in detecting SITFs and assessing the fault severity. However, FPM can identify the faulty phase and be implemented online, while TFC is not able to detect faulty phases. A transfer learning-based SITF detection method is then proposed that uses globally pre- trained CNN-based networks from TensorFlow Hub. In this method, positive and negative sequence current magnitudes and the negative sequence current angle are used as the fault indices, and they are transformed into layers of color image representations of the motor's operating state. By fine-tuning pre-trained CNNs on these image datasets, the model aims to achieve accurate SITF diagnosis, severity estimation, and faulty phase identification with the minimal feature engineering. This proposed method is validated using experimental data of the same 2.2 kW induction motor. By using pre-trained networks and current sequence components as fault features, the initial round and fine-tuning time can be significantly reduced when comparing to CNNs built from scratch. It also demonstrates a rapid decision-making capability for online implementation. Two threshold-based SITF detection approaches are also developed in this research. The first threshold-based SITF detection method uses the negative sequence current component (I2) analysis for SITF diagnosis, where the negative sequence current level (NCL) is used for fault detection, and the negative sequence current angle (∡I2) is used for faulty phase identification. Through experimental validation on a 2.2 kW motor under various unbalanced voltage conditions, a detection threshold has been established with three distinct angular zones for ∡I2 to detect defective phases. This method demonstrates successful SITF detection across different fault severities and motor loading conditions, showing a strong linear correlation between the fault severity and NCL. It can also be used for variable frequency drive (VFD)-fed induction motors, and a higher output frequency of the drive shows better fault diagnosis performance. The second threshold-based SITF detection method uses negative sequence components (V2) of the induction motor’s terminal voltage for detecting both SITFs and single phasing conditions. The method compares negative sequence voltage magnitude against zero sequence voltage magnitude to establish a superior fault detection criterion. It is validated through ANSYS Maxwell simulations and experimental testing, considering various fault severities and loading conditions. It can detect early-stage SITFs while maintaining the effectiveness with a unbalanced voltage supply, and thus, enhancing reliability and predictive maintenance capabilities of induction motors.","abstract_html":"Stator inter-turn faults (SITFs) represent a significant portion of induction motor failures, potentially causing costly disruptions if undetected. Traditional fault detection methods often rely on complex feature engineering, lack generalizability, and may not be sensitive to early-stage SITFs. This research aims to develop advanced techniques for accurate, robust, early detection of SITFs, fault severity evaluation, and faulty phase identification for line-connected induction motors. A novel two-dimensional (2D) convolutional neural network (CNN)-based SITF detection technique is first proposed, where the fundamental frequency phasor magnitude (FPM) and the third harmonic frequency component (TFC) of three-phase stator currents are used as the fault detection signals. The extracted FPM and TFC signals from the three-phase currents are transformed into three-dimensional (3D) color images in a Red-Green-Blue (RGB) structure using a current-to-image transformation mechanism. The developed CNN model is validated using the experimental data of a line-connected 2.2 kW induction motor operating under healthy and various SITF conditions, and different motor loadings and unbalanced supply voltage are also considered. Both FPM and TFC exhibit almost identical precision in detecting SITFs and assessing the fault severity. However, FPM can identify the faulty phase and be implemented online, while TFC is not able to detect faulty phases. A transfer learning-based SITF detection method is then proposed that uses globally pre- trained CNN-based networks from TensorFlow Hub. In this method, positive and negative sequence current magnitudes and the negative sequence current angle are used as the fault indices, and they are transformed into layers of color image representations of the motor&#x27;s operating state. By fine-tuning pre-trained CNNs on these image datasets, the model aims to achieve accurate SITF diagnosis, severity estimation, and faulty phase identification with the minimal feature engineering. This proposed method is validated using experimental data of the same 2.2 kW induction motor. By using pre-trained networks and current sequence components as fault features, the initial round and fine-tuning time can be significantly reduced when comparing to CNNs built from scratch. It also demonstrates a rapid decision-making capability for online implementation. Two threshold-based SITF detection approaches are also developed in this research. The first threshold-based SITF detection method uses the negative sequence current component (I2) analysis for SITF diagnosis, where the negative sequence current level (NCL) is used for fault detection, and the negative sequence current angle (∡I2) is used for faulty phase identification. Through experimental validation on a 2.2 kW motor under various unbalanced voltage conditions, a detection threshold has been established with three distinct angular zones for ∡I2 to detect defective phases. This method demonstrates successful SITF detection across different fault severities and motor loading conditions, showing a strong linear correlation between the fault severity and NCL. It can also be used for variable frequency drive (VFD)-fed induction motors, and a higher output frequency of the drive shows better fault diagnosis performance. The second threshold-based SITF detection method uses negative sequence components (V2) of the induction motor’s terminal voltage for detecting both SITFs and single phasing conditions. The method compares negative sequence voltage magnitude against zero sequence voltage magnitude to establish a superior fault detection criterion. It is validated through ANSYS Maxwell simulations and experimental testing, considering various fault severities and loading conditions. It can detect early-stage SITFs while maintaining the effectiveness with a unbalanced voltage supply, and thus, enhancing reliability and predictive maintenance capabilities of induction motors.","abstract_has_math":false,"creators":["Nazemi, Mohammadhossein"],"institution":"University of Saskatchewan","degree_name":"Doctor of Philosophy (Ph.D.)","degree_level":"Doctoral","degree_discipline":"Electrical Engineering","degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Liang, Xiaodong"],"committee_chairs":[],"committee_members":["Bui, Francis","Karki, Rajesh","Saadat Mehr, Aryan","Wu, Fangxiang","Lai, Chunyan"],"year":2025,"date_issued":"2025-04-24","date_published":"2025-04-24","updated_at":"2026-11-19T10:11:34Z","subjects":["Stator Inter-Turn Fault (SITF), Induction Motors, Convolutional Neural Networks, Fault Diagnosis, Negative Sequence Current, Air-Gap Magnetic Field, Sequence Components Analysis, Transfer Learning, Threshold-Based Detection, Real-Time Monitoring"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10388/16878","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10388/16878","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":"embargoed","embargo_until":"2026-04-24","access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Asask%3Aoai%3Aharvest.usask.ca%3A10388%2F16878","prefix":"oai_dc"},"source_record":{"url":"https://harvest.usask.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aharvest.usask.ca%3A10388%2F16878","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Liang, Xiaodong"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Bui, Francis","Karki, Rajesh","Saadat Mehr, Aryan","Wu, Fangxiang","Lai, Chunyan"]},{"key":"dc:creator","label":"Author","values":["Nazemi, Mohammadhossein"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-24T17:48:48Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2025"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-04"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2026-04-24"]},{"key":"dc:date.issued","label":"Date","values":["2025-04-24"]},{"key":"dc:date.liftdate","label":"Dc Date Liftdate","values":["2026-04-24"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["April 2025"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2025-04-24T17:48:49Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (Ph.D.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Saskatchewan"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Stator Inter-Turn Fault (SITF), Induction Motors, Convolutional Neural Networks, Fault Diagnosis, Negative Sequence Current, Air-Gap Magnetic Field, Sequence Components Analysis, Transfer Learning, Threshold-Based Detection, Real-Time Monitoring"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10388/16878"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Stator inter-turn faults (SITFs) represent a significant portion of induction motor failures, potentially causing costly disruptions if undetected. Traditional fault detection methods often rely on complex feature engineering, lack generalizability, and may not be sensitive to early-stage SITFs. This research aims to develop advanced techniques for accurate, robust, early detection of SITFs, fault severity evaluation, and faulty phase identification for line-connected induction motors. A novel two-dimensional (2D) convolutional neural network (CNN)-based SITF detection technique is first proposed, where the fundamental frequency phasor magnitude (FPM) and the third harmonic frequency component (TFC) of three-phase stator currents are used as the fault detection signals. The extracted FPM and TFC signals from the three-phase currents are transformed into three-dimensional (3D) color images in a Red-Green-Blue (RGB) structure using a current-to-image transformation mechanism. The developed CNN model is validated using the experimental data of a line-connected 2.2 kW induction motor operating under healthy and various SITF conditions, and different motor loadings and unbalanced supply voltage are also considered. Both FPM and TFC exhibit almost identical precision in detecting SITFs and assessing the fault severity. However, FPM can identify the faulty phase and be implemented online, while TFC is not able to detect faulty phases. A transfer learning-based SITF detection method is then proposed that uses globally pre- trained CNN-based networks from TensorFlow Hub. In this method, positive and negative sequence current magnitudes and the negative sequence current angle are used as the fault indices, and they are transformed into layers of color image representations of the motor's operating state. By fine-tuning pre-trained CNNs on these image datasets, the model aims to achieve accurate SITF diagnosis, severity estimation, and faulty phase identification with the minimal feature engineering. This proposed method is validated using experimental data of the same 2.2 kW induction motor. By using pre-trained networks and current sequence components as fault features, the initial round and fine-tuning time can be significantly reduced when comparing to CNNs built from scratch. It also demonstrates a rapid decision-making capability for online implementation. Two threshold-based SITF detection approaches are also developed in this research. The first threshold-based SITF detection method uses the negative sequence current component (I2) analysis for SITF diagnosis, where the negative sequence current level (NCL) is used for fault detection, and the negative sequence current angle (∡I2) is used for faulty phase identification. Through experimental validation on a 2.2 kW motor under various unbalanced voltage conditions, a detection threshold has been established with three distinct angular zones for ∡I2 to detect defective phases. This method demonstrates successful SITF detection across different fault severities and motor loading conditions, showing a strong linear correlation between the fault severity and NCL. It can also be used for variable frequency drive (VFD)-fed induction motors, and a higher output frequency of the drive shows better fault diagnosis performance. The second threshold-based SITF detection method uses negative sequence components (V2) of the induction motor’s terminal voltage for detecting both SITFs and single phasing conditions. The method compares negative sequence voltage magnitude against zero sequence voltage magnitude to establish a superior fault detection criterion. It is validated through ANSYS Maxwell simulations and experimental testing, considering various fault severities and loading conditions. It can detect early-stage SITFs while maintaining the effectiveness with a unbalanced voltage supply, and thus, enhancing reliability and predictive maintenance capabilities of induction motors."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Advanced Stator Inter-Turn Fault Diagnosis Methods for Line-Connected Induction Motors"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Liang, Xiaodong"],"dc:contributor.committeemember":["Bui, Francis","Karki, Rajesh","Saadat Mehr, Aryan","Wu, Fangxiang","Lai, Chunyan"],"dc:creator":["Nazemi, Mohammadhossein"],"dc:date.accessioned":["2025-04-24T17:48:48Z"],"dc:date.copyright":["2025"],"dc:date.created":["2025-04"],"dc:date.embargo":["2026-04-24"],"dc:date.issued":["2025-04-24"],"dc:date.liftdate":["2026-04-24"],"dc:date.submitted":["April 2025"],"dc:date.updated":["2025-04-24T17:48:49Z"],"dc:description.abstract":["Stator inter-turn faults (SITFs) represent a significant portion of induction motor failures, potentially causing costly disruptions if undetected. Traditional fault detection methods often rely on complex feature engineering, lack generalizability, and may not be sensitive to early-stage SITFs. This research aims to develop advanced techniques for accurate, robust, early detection of SITFs, fault severity evaluation, and faulty phase identification for line-connected induction motors. A novel two-dimensional (2D) convolutional neural network (CNN)-based SITF detection technique is first proposed, where the fundamental frequency phasor magnitude (FPM) and the third harmonic frequency component (TFC) of three-phase stator currents are used as the fault detection signals. The extracted FPM and TFC signals from the three-phase currents are transformed into three-dimensional (3D) color images in a Red-Green-Blue (RGB) structure using a current-to-image transformation mechanism. The developed CNN model is validated using the experimental data of a line-connected 2.2 kW induction motor operating under healthy and various SITF conditions, and different motor loadings and unbalanced supply voltage are also considered. Both FPM and TFC exhibit almost identical precision in detecting SITFs and assessing the fault severity. However, FPM can identify the faulty phase and be implemented online, while TFC is not able to detect faulty phases. A transfer learning-based SITF detection method is then proposed that uses globally pre- trained CNN-based networks from TensorFlow Hub. In this method, positive and negative sequence current magnitudes and the negative sequence current angle are used as the fault indices, and they are transformed into layers of color image representations of the motor's operating state. By fine-tuning pre-trained CNNs on these image datasets, the model aims to achieve accurate SITF diagnosis, severity estimation, and faulty phase identification with the minimal feature engineering. This proposed method is validated using experimental data of the same 2.2 kW induction motor. By using pre-trained networks and current sequence components as fault features, the initial round and fine-tuning time can be significantly reduced when comparing to CNNs built from scratch. It also demonstrates a rapid decision-making capability for online implementation. Two threshold-based SITF detection approaches are also developed in this research. The first threshold-based SITF detection method uses the negative sequence current component (I2) analysis for SITF diagnosis, where the negative sequence current level (NCL) is used for fault detection, and the negative sequence current angle (∡I2) is used for faulty phase identification. Through experimental validation on a 2.2 kW motor under various unbalanced voltage conditions, a detection threshold has been established with three distinct angular zones for ∡I2 to detect defective phases. This method demonstrates successful SITF detection across different fault severities and motor loading conditions, showing a strong linear correlation between the fault severity and NCL. It can also be used for variable frequency drive (VFD)-fed induction motors, and a higher output frequency of the drive shows better fault diagnosis performance. The second threshold-based SITF detection method uses negative sequence components (V2) of the induction motor’s terminal voltage for detecting both SITFs and single phasing conditions. The method compares negative sequence voltage magnitude against zero sequence voltage magnitude to establish a superior fault detection criterion. It is validated through ANSYS Maxwell simulations and experimental testing, considering various fault severities and loading conditions. It can detect early-stage SITFs while maintaining the effectiveness with a unbalanced voltage supply, and thus, enhancing reliability and predictive maintenance capabilities of induction motors."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/10388/16878"],"dc:language.iso":["en"],"dc:subject":["Stator Inter-Turn Fault (SITF), Induction Motors, Convolutional Neural Networks, Fault Diagnosis, Negative Sequence Current, Air-Gap Magnetic Field, Sequence Components Analysis, Transfer Learning, Threshold-Based Detection, Real-Time Monitoring"],"dc:title":["Advanced Stator Inter-Turn Fault Diagnosis Methods for Line-Connected Induction Motors"],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"thesis:degree_department":["Electrical and Computer Engineering"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Doctor of Philosophy (Ph.D.)"],"thesis:institution_name":["University of Saskatchewan"]},"updated_at":"2026-11-19T10:11:34Z"}