{"id":{"repo_id":"sask","oai_identifier":"oai:harvest.usask.ca:10388/17198"},"canonical_url":"https://search.ndltd.org/etd/sask/oai:harvest.usask.ca:10388/17198","repository":{"repo_id":"sask","name":"University of Saskatchewan","base_url":"https://harvest.usask.ca/server/oai/request"},"display":{"title":"Analytical Benchmark Solutions for the Cardiac EMI Model","abstract":"The cardiac extracellular--membrane--intracellular (EMI) model is a detailed mathematical framework for simulating the electrical activity of the heart. Compared to traditional monodomain and bidomain models, the cardiac EMI model resolves the intracellular, membrane, and extracellular domains explicitly, enabling more accurate representation of cardiac dynamics, particularly under pathological conditions. This thesis presents several analytical solutions to the EMI model derived under simplified geometries and physiological assumptions. These include a family of solutions for a single two-dimensional circular cell in polar coordinates and for a pair of coupled three-dimensional semi-spherical cells in spherical coordinates, based on radial symmetry and equal intra- and extracellular conductivities. Additionally, a manufactured solution is introduced for a system of N three-dimensional cells in Cartesian coordinates, enabling comprehensive numerical validation. These solutions are employed to assess the accuracy of a numerical implementation based on the mortar finite element method combined with operator-splitting (OS) methods. Numerical experiments confirm that the analytical and manufactured solutions serve as effective benchmarks for verifying simulation accuracy. A temporal convergence study demonstrates first-order accuracy for the Lie--Trotter OS method, and improved order accuracy for simulations using the Strang OS method, both employing RK subintegrators. The numerical framework is also applied to simulate clinically relevant cardiac channelopathies, such as Long QT1 and Brugada syndromes, using the ten Tusscher--Panfilov cell model. The results highlight the potential of the cardiac EMI model and associated numerical methods for high-fidelity cardiac simulations and telemedicine applications.","abstract_html":"The cardiac extracellular--membrane--intracellular (EMI) model is a detailed mathematical framework for simulating the electrical activity of the heart. Compared to traditional monodomain and bidomain models, the cardiac EMI model resolves the intracellular, membrane, and extracellular domains explicitly, enabling more accurate representation of cardiac dynamics, particularly under pathological conditions. This thesis presents several analytical solutions to the EMI model derived under simplified geometries and physiological assumptions. These include a family of solutions for a single two-dimensional circular cell in polar coordinates and for a pair of coupled three-dimensional semi-spherical cells in spherical coordinates, based on radial symmetry and equal intra- and extracellular conductivities. Additionally, a manufactured solution is introduced for a system of N three-dimensional cells in Cartesian coordinates, enabling comprehensive numerical validation. These solutions are employed to assess the accuracy of a numerical implementation based on the mortar finite element method combined with operator-splitting (OS) methods. Numerical experiments confirm that the analytical and manufactured solutions serve as effective benchmarks for verifying simulation accuracy. A temporal convergence study demonstrates first-order accuracy for the Lie--Trotter OS method, and improved order accuracy for simulations using the Strang OS method, both employing RK subintegrators. The numerical framework is also applied to simulate clinically relevant cardiac channelopathies, such as Long QT1 and Brugada syndromes, using the ten Tusscher--Panfilov cell model. The results highlight the potential of the cardiac EMI model and associated numerical methods for high-fidelity cardiac simulations and telemedicine applications.","abstract_has_math":false,"creators":["Ballesteros Alvarez, Carlos A."],"institution":"University of Saskatchewan","degree_name":"Master of Science (M.Sc.)","degree_level":"Masters","degree_discipline":"Mathematics","degree_department":"Mathematics and Statistics","school":null,"contributors":[],"advisors":["Spiteri, Raymond J"],"committee_chairs":[],"committee_members":["Patrick, George W","Rayan, Steven","Cheviakov, Alexei"],"year":2025,"date_issued":"2025-08-25","date_published":"2025-08-25","updated_at":"2026-11-19T10:00:31Z","subjects":["Extracellular-Membrane-Intracellular model","Manufactured solution","Cardiac electrophysiology","Operator-splitting method","Mortar finite element method"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0009-0003-9631-3502"],"render_values":[{"text":"0009-0003-9631-3502","href":"https://orcid.org/0009-0003-9631-3502","code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/10388/17198","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10388/17198","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Asask%3Aoai%3Aharvest.usask.ca%3A10388%2F17198","prefix":"oai_dc"},"source_record":{"url":"https://harvest.usask.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aharvest.usask.ca%3A10388%2F17198","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Spiteri, Raymond J"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Patrick, George W","Rayan, Steven","Cheviakov, Alexei"]},{"key":"dc:creator","label":"Author","values":["Ballesteros Alvarez, Carlos A."]},{"key":"person:identifier.orcid","label":"ORCID","values":["0009-0003-9631-3502"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-08-25T16:01:43Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-08-25T16:01:43Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2025"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-11"]},{"key":"dc:date.issued","label":"Date","values":["2025-08-25"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["November 2025"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2025-08-25T16:01:44Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_department","label":"Department","values":["Mathematics and Statistics"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mathematics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.Sc.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Saskatchewan"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Extracellular-Membrane-Intracellular model","Manufactured solution","Cardiac electrophysiology","Operator-splitting method","Mortar finite element method"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10388/17198"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The cardiac extracellular--membrane--intracellular (EMI) model is a detailed mathematical framework for simulating the electrical activity of the heart. Compared to traditional monodomain and bidomain models, the cardiac EMI model resolves the intracellular, membrane, and extracellular domains explicitly, enabling more accurate representation of cardiac dynamics, particularly under pathological conditions. This thesis presents several analytical solutions to the EMI model derived under simplified geometries and physiological assumptions. These include a family of solutions for a single two-dimensional circular cell in polar coordinates and for a pair of coupled three-dimensional semi-spherical cells in spherical coordinates, based on radial symmetry and equal intra- and extracellular conductivities. Additionally, a manufactured solution is introduced for a system of N three-dimensional cells in Cartesian coordinates, enabling comprehensive numerical validation. These solutions are employed to assess the accuracy of a numerical implementation based on the mortar finite element method combined with operator-splitting (OS) methods. Numerical experiments confirm that the analytical and manufactured solutions serve as effective benchmarks for verifying simulation accuracy. A temporal convergence study demonstrates first-order accuracy for the Lie--Trotter OS method, and improved order accuracy for simulations using the Strang OS method, both employing RK subintegrators. The numerical framework is also applied to simulate clinically relevant cardiac channelopathies, such as Long QT1 and Brugada syndromes, using the ten Tusscher--Panfilov cell model. The results highlight the potential of the cardiac EMI model and associated numerical methods for high-fidelity cardiac simulations and telemedicine applications."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Analytical Benchmark Solutions for the Cardiac EMI Model"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Spiteri, Raymond J"],"dc:contributor.committeemember":["Patrick, George W","Rayan, Steven","Cheviakov, Alexei"],"dc:creator":["Ballesteros Alvarez, Carlos A."],"dc:date.accessioned":["2025-08-25T16:01:43Z"],"dc:date.available":["2025-08-25T16:01:43Z"],"dc:date.copyright":["2025"],"dc:date.created":["2025-11"],"dc:date.issued":["2025-08-25"],"dc:date.submitted":["November 2025"],"dc:date.updated":["2025-08-25T16:01:44Z"],"dc:description.abstract":["The cardiac extracellular--membrane--intracellular (EMI) model is a detailed mathematical framework for simulating the electrical activity of the heart. Compared to traditional monodomain and bidomain models, the cardiac EMI model resolves the intracellular, membrane, and extracellular domains explicitly, enabling more accurate representation of cardiac dynamics, particularly under pathological conditions. This thesis presents several analytical solutions to the EMI model derived under simplified geometries and physiological assumptions. These include a family of solutions for a single two-dimensional circular cell in polar coordinates and for a pair of coupled three-dimensional semi-spherical cells in spherical coordinates, based on radial symmetry and equal intra- and extracellular conductivities. Additionally, a manufactured solution is introduced for a system of N three-dimensional cells in Cartesian coordinates, enabling comprehensive numerical validation. These solutions are employed to assess the accuracy of a numerical implementation based on the mortar finite element method combined with operator-splitting (OS) methods. Numerical experiments confirm that the analytical and manufactured solutions serve as effective benchmarks for verifying simulation accuracy. A temporal convergence study demonstrates first-order accuracy for the Lie--Trotter OS method, and improved order accuracy for simulations using the Strang OS method, both employing RK subintegrators. The numerical framework is also applied to simulate clinically relevant cardiac channelopathies, such as Long QT1 and Brugada syndromes, using the ten Tusscher--Panfilov cell model. The results highlight the potential of the cardiac EMI model and associated numerical methods for high-fidelity cardiac simulations and telemedicine applications."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/10388/17198"],"dc:language.iso":["en"],"dc:subject":["Extracellular-Membrane-Intracellular model","Manufactured solution","Cardiac electrophysiology","Operator-splitting method","Mortar finite element method"],"dc:title":["Analytical Benchmark Solutions for the Cardiac EMI Model"],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"person:identifier.orcid":["0009-0003-9631-3502"],"thesis:degree_department":["Mathematics and Statistics"],"thesis:degree_discipline":["Mathematics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science (M.Sc.)"],"thesis:institution_name":["University of Saskatchewan"]},"updated_at":"2026-11-19T10:00:31Z"}