{"id":{"repo_id":"sask","oai_identifier":"oai:harvest.usask.ca:10388/17246"},"canonical_url":"https://search.ndltd.org/etd/sask/oai:harvest.usask.ca:10388/17246","repository":{"repo_id":"sask","name":"University of Saskatchewan","base_url":"https://harvest.usask.ca/server/oai/request"},"display":{"title":"A GENERAL DESIGN FRAMEWORK FOR THE CASING OF THE PACEMAKER FOR PREVENTING THE RISK OF EARLIER DAMAGE DUE TO MATERIAL DEGRADATION OF THE CASING","abstract":"Cardiac pacemakers are essential for restoring physiological rhythm, yet designing these complex implants for long-term reliability presents significant challenges. A critical aspect is preventing early device failure due to the material degradation of the casing of cardiac pacemakers within an unexpected physical and physiological environment. This thesis aims to develop a general framework for designing cardiac pacemakers with a focus on the casing due to its importance to the reliability and robustness of the whole pacemaker in human body. The importance of the casing to the whole pacemaker is because the casing material can likely degrade, thus leading to the structural integrity deficiency with the whole pacemaker. Specifically, the general framework is built with the help of the systematic design methodology, including the design phase theory. This framework gives a context for the embodiment design of the casing of a pacemaker with consideration of the material degradation of the casing. Along with the framework, the thesis develops a simulation system, expected to aid in the embodiment design of the casing, to determine two performance attributes, namely (1) the pressure on the casing and (2) the temperature rise of the casing, given various options of materials and dimensions of the casing. It is noted that according to clinical experiences and ISO standards (14708, 10993), these two performance attributes are major criteria to the baseline safety of the pacemaker. The simulation system was then used to evaluate the baseline safety of a specific design of the casing, i.e., to calculate the pressure and temperature rise of the casing in design with consideration of its material degradation. The contribution of this thesis includes (1) the development of a general framework for designing the pacemaker, from the technical specification of the pacemaker, to the conceptual design of the pacemaker, and to the embodiment design of the casing in a total traceable manner, and (2) the development of an accurate simulation system for the embodiment design of the casing with consideration of the material degradation of the casing. The future work includes (1) redesign of the existing pacemakers commercially available for an optimal performance of the whole pacemaker by consideration of the material degradation of the casing and subsequent structural integrity deficiency with the whole pacemaker and (2) incorporation of a more accurate way to consider the material degradation of the casing, e.g., material degradation history.","abstract_html":"Cardiac pacemakers are essential for restoring physiological rhythm, yet designing these complex implants for long-term reliability presents significant challenges. A critical aspect is preventing early device failure due to the material degradation of the casing of cardiac pacemakers within an unexpected physical and physiological environment. This thesis aims to develop a general framework for designing cardiac pacemakers with a focus on the casing due to its importance to the reliability and robustness of the whole pacemaker in human body. The importance of the casing to the whole pacemaker is because the casing material can likely degrade, thus leading to the structural integrity deficiency with the whole pacemaker. Specifically, the general framework is built with the help of the systematic design methodology, including the design phase theory. This framework gives a context for the embodiment design of the casing of a pacemaker with consideration of the material degradation of the casing. Along with the framework, the thesis develops a simulation system, expected to aid in the embodiment design of the casing, to determine two performance attributes, namely (1) the pressure on the casing and (2) the temperature rise of the casing, given various options of materials and dimensions of the casing. It is noted that according to clinical experiences and ISO standards (14708, 10993), these two performance attributes are major criteria to the baseline safety of the pacemaker. The simulation system was then used to evaluate the baseline safety of a specific design of the casing, i.e., to calculate the pressure and temperature rise of the casing in design with consideration of its material degradation. The contribution of this thesis includes (1) the development of a general framework for designing the pacemaker, from the technical specification of the pacemaker, to the conceptual design of the pacemaker, and to the embodiment design of the casing in a total traceable manner, and (2) the development of an accurate simulation system for the embodiment design of the casing with consideration of the material degradation of the casing. The future work includes (1) redesign of the existing pacemakers commercially available for an optimal performance of the whole pacemaker by consideration of the material degradation of the casing and subsequent structural integrity deficiency with the whole pacemaker and (2) incorporation of a more accurate way to consider the material degradation of the casing, e.g., material degradation history.","abstract_has_math":false,"creators":["Odeyemi, Josiah Ayobami"],"institution":"University of Saskatchewan","degree_name":"Master of Science (M.Sc.)","degree_level":"Masters","degree_discipline":"Biomedical Engineering","degree_department":"Biomedical Engineering","school":null,"contributors":[],"advisors":["Zhang, Chris W"],"committee_chairs":[],"committee_members":["Ip, Wai H","Chen, Li L","Song, Ki-Young KY"],"year":2025,"date_issued":"2025-09-10","date_published":"2025-09-10","updated_at":"2026-11-19T09:59:06Z","subjects":["Pacemaker casing Thermal simulation Material degradation ANSYS Workbench Structural analysis"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10388/17246","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10388/17246","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://harvest.usask.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aharvest.usask.ca%3A10388%2F17246","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Zhang, Chris W"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Ip, Wai H","Chen, Li L","Song, Ki-Young KY"]},{"key":"dc:creator","label":"Author","values":["Odeyemi, Josiah Ayobami"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-09-10T16:00:14Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-09-10T16:00:14Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2025"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-11"]},{"key":"dc:date.issued","label":"Date","values":["2025-09-10"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["November 2025"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2025-09-10T16:00:14Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_department","label":"Department","values":["Biomedical Engineering"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.Sc.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Saskatchewan"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Pacemaker casing Thermal simulation Material degradation ANSYS Workbench Structural analysis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10388/17246"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Cardiac pacemakers are essential for restoring physiological rhythm, yet designing these complex implants for long-term reliability presents significant challenges. A critical aspect is preventing early device failure due to the material degradation of the casing of cardiac pacemakers within an unexpected physical and physiological environment. This thesis aims to develop a general framework for designing cardiac pacemakers with a focus on the casing due to its importance to the reliability and robustness of the whole pacemaker in human body. The importance of the casing to the whole pacemaker is because the casing material can likely degrade, thus leading to the structural integrity deficiency with the whole pacemaker. Specifically, the general framework is built with the help of the systematic design methodology, including the design phase theory. This framework gives a context for the embodiment design of the casing of a pacemaker with consideration of the material degradation of the casing. Along with the framework, the thesis develops a simulation system, expected to aid in the embodiment design of the casing, to determine two performance attributes, namely (1) the pressure on the casing and (2) the temperature rise of the casing, given various options of materials and dimensions of the casing. It is noted that according to clinical experiences and ISO standards (14708, 10993), these two performance attributes are major criteria to the baseline safety of the pacemaker. The simulation system was then used to evaluate the baseline safety of a specific design of the casing, i.e., to calculate the pressure and temperature rise of the casing in design with consideration of its material degradation. The contribution of this thesis includes (1) the development of a general framework for designing the pacemaker, from the technical specification of the pacemaker, to the conceptual design of the pacemaker, and to the embodiment design of the casing in a total traceable manner, and (2) the development of an accurate simulation system for the embodiment design of the casing with consideration of the material degradation of the casing. The future work includes (1) redesign of the existing pacemakers commercially available for an optimal performance of the whole pacemaker by consideration of the material degradation of the casing and subsequent structural integrity deficiency with the whole pacemaker and (2) incorporation of a more accurate way to consider the material degradation of the casing, e.g., material degradation history."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A GENERAL DESIGN FRAMEWORK FOR THE CASING OF THE PACEMAKER FOR PREVENTING THE RISK OF EARLIER DAMAGE DUE TO MATERIAL DEGRADATION OF THE CASING"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Zhang, Chris W"],"dc:contributor.committeemember":["Ip, Wai H","Chen, Li L","Song, Ki-Young KY"],"dc:creator":["Odeyemi, Josiah Ayobami"],"dc:date.accessioned":["2025-09-10T16:00:14Z"],"dc:date.available":["2025-09-10T16:00:14Z"],"dc:date.copyright":["2025"],"dc:date.created":["2025-11"],"dc:date.issued":["2025-09-10"],"dc:date.submitted":["November 2025"],"dc:date.updated":["2025-09-10T16:00:14Z"],"dc:description.abstract":["Cardiac pacemakers are essential for restoring physiological rhythm, yet designing these complex implants for long-term reliability presents significant challenges. A critical aspect is preventing early device failure due to the material degradation of the casing of cardiac pacemakers within an unexpected physical and physiological environment. This thesis aims to develop a general framework for designing cardiac pacemakers with a focus on the casing due to its importance to the reliability and robustness of the whole pacemaker in human body. The importance of the casing to the whole pacemaker is because the casing material can likely degrade, thus leading to the structural integrity deficiency with the whole pacemaker. Specifically, the general framework is built with the help of the systematic design methodology, including the design phase theory. This framework gives a context for the embodiment design of the casing of a pacemaker with consideration of the material degradation of the casing. Along with the framework, the thesis develops a simulation system, expected to aid in the embodiment design of the casing, to determine two performance attributes, namely (1) the pressure on the casing and (2) the temperature rise of the casing, given various options of materials and dimensions of the casing. It is noted that according to clinical experiences and ISO standards (14708, 10993), these two performance attributes are major criteria to the baseline safety of the pacemaker. The simulation system was then used to evaluate the baseline safety of a specific design of the casing, i.e., to calculate the pressure and temperature rise of the casing in design with consideration of its material degradation. The contribution of this thesis includes (1) the development of a general framework for designing the pacemaker, from the technical specification of the pacemaker, to the conceptual design of the pacemaker, and to the embodiment design of the casing in a total traceable manner, and (2) the development of an accurate simulation system for the embodiment design of the casing with consideration of the material degradation of the casing. The future work includes (1) redesign of the existing pacemakers commercially available for an optimal performance of the whole pacemaker by consideration of the material degradation of the casing and subsequent structural integrity deficiency with the whole pacemaker and (2) incorporation of a more accurate way to consider the material degradation of the casing, e.g., material degradation history."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/10388/17246"],"dc:language.iso":["en"],"dc:subject":["Pacemaker casing Thermal simulation Material degradation ANSYS Workbench Structural analysis"],"dc:title":["A GENERAL DESIGN FRAMEWORK FOR THE CASING OF THE PACEMAKER FOR PREVENTING THE RISK OF EARLIER DAMAGE DUE TO MATERIAL DEGRADATION OF THE CASING"],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"thesis:degree_department":["Biomedical Engineering"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science (M.Sc.)"],"thesis:institution_name":["University of Saskatchewan"]},"updated_at":"2026-11-19T09:59:06Z"}