{"id":{"repo_id":"sask","oai_identifier":"oai:harvest.usask.ca:10388/17776"},"canonical_url":"https://search.ndltd.org/etd/sask/oai:harvest.usask.ca:10388/17776","repository":{"repo_id":"sask","name":"University of Saskatchewan","base_url":"https://harvest.usask.ca/server/oai/request"},"display":{"title":"The Development of a Laboratory Scale Pressuremeter for use in Loose Sands","abstract":"This study aimed to develop a laboratory-scale pressuremeter capable of applying a minimum 20% cavity strain to fully capture the shearing behaviour of a loose sand. Proof of concept testing was conducted on three pressuremeter probes: the original University of Western Australia (UWA) probe (Johnston et al., 2013), a clone of this probe (USask probe) to reduce the risk of damage, and a newly designed probe incorporating two linear variable differential transducers (LVDTs) installed at 90° to each other to measure displacement during expansion. Two soils were selected for testing: kaolinite and a uniform fine sand. Laboratory testing established baseline material properties for comparison with pressuremeter results. Kaolinite was tested using unconsolidated undrained (UU) triaxial tests to determine undrained shear strength (s_u) and secant shear modulus (G_s). For the sand, routine characterization included grain size distributions, a soil water characteristic curve, and specific gravity, while shear strength was assessed via direct shear (DS), direct simple shear (DSS), ring shear (RS), and consolidated undrained (CU) triaxial tests to estimate the critical state friction angle (\\phi_{cs}) and G_s. Proof of concept testing on both cohesive and cohesionless soils measured pressure-expansion curves that could be interpreted and compared to the laboratory results. Theoretical spherical cavity expansion models were fit to the measured curves, confirming that all three probes exhibited behaviour consistent with spherical expansion. Challenges were encountered capturing contraction during unload-reload cycles with the UWA and LVDT probes, limiting the ability to interpret the linear and non-linear shear moduli. The LVDT probe effectively captured expansion data, but achieved a maximum cavity strain of only 12% to 13%, falling short of the 20% target. Discrepancies between the two strain arms, difficulties in capturing contraction, possible friction between the arms and the probe body, or damage to one of the sensors were identified as contributing factors. Recommendations for future probe design iterations are provided to address these limitations.","abstract_html":"This study aimed to develop a laboratory-scale pressuremeter capable of applying a minimum 20% cavity strain to fully capture the shearing behaviour of a loose sand. Proof of concept testing was conducted on three pressuremeter probes: the original University of Western Australia (UWA) probe (Johnston et al., 2013), a clone of this probe (USask probe) to reduce the risk of damage, and a newly designed probe incorporating two linear variable differential transducers (LVDTs) installed at 90° to each other to measure displacement during expansion. Two soils were selected for testing: kaolinite and a uniform fine sand. Laboratory testing established baseline material properties for comparison with pressuremeter results. Kaolinite was tested using unconsolidated undrained (UU) triaxial tests to determine undrained shear strength (s_u) and secant shear modulus (G_s). For the sand, routine characterization included grain size distributions, a soil water characteristic curve, and specific gravity, while shear strength was assessed via direct shear (DS), direct simple shear (DSS), ring shear (RS), and consolidated undrained (CU) triaxial tests to estimate the critical state friction angle (\\phi_{cs}) and G_s. Proof of concept testing on both cohesive and cohesionless soils measured pressure-expansion curves that could be interpreted and compared to the laboratory results. Theoretical spherical cavity expansion models were fit to the measured curves, confirming that all three probes exhibited behaviour consistent with spherical expansion. Challenges were encountered capturing contraction during unload-reload cycles with the UWA and LVDT probes, limiting the ability to interpret the linear and non-linear shear moduli. The LVDT probe effectively captured expansion data, but achieved a maximum cavity strain of only 12% to 13%, falling short of the 20% target. Discrepancies between the two strain arms, difficulties in capturing contraction, possible friction between the arms and the probe body, or damage to one of the sensors were identified as contributing factors. Recommendations for future probe design iterations are provided to address these limitations.","abstract_has_math":false,"creators":["Wenz, Matthew"],"institution":"University of Saskatchewan","degree_name":"Master of Science (M.Sc.)","degree_level":"Masters","degree_discipline":"Civil Engineering","degree_department":"Civil and Geological Engineering","school":null,"contributors":[],"advisors":["Elwood, David"],"committee_chairs":[],"committee_members":["Hawkes, Christopher","Fleming, Ian"],"year":2026,"date_issued":"2026-01-14","date_published":"2026-01-14","updated_at":"2026-11-19T10:30:48Z","subjects":["In-situ testing","Laboratory testing","Pressuremeter","Loose Sands"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10388/17776","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10388/17776","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Asask%3Aoai%3Aharvest.usask.ca%3A10388%2F17776","prefix":"oai_dc"},"source_record":{"url":"https://harvest.usask.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aharvest.usask.ca%3A10388%2F17776","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Elwood, David"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Hawkes, Christopher","Fleming, Ian"]},{"key":"dc:creator","label":"Author","values":["Wenz, Matthew"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-01-14T21:01:54Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-01-14T21:01:54Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2025"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2026-05"]},{"key":"dc:date.issued","label":"Date","values":["2026-01-14"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2026"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-01-14T21:01:55Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_department","label":"Department","values":["Civil and Geological Engineering"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.Sc.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Saskatchewan"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["In-situ testing","Laboratory testing","Pressuremeter","Loose Sands"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10388/17776"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This study aimed to develop a laboratory-scale pressuremeter capable of applying a minimum 20% cavity strain to fully capture the shearing behaviour of a loose sand. Proof of concept testing was conducted on three pressuremeter probes: the original University of Western Australia (UWA) probe (Johnston et al., 2013), a clone of this probe (USask probe) to reduce the risk of damage, and a newly designed probe incorporating two linear variable differential transducers (LVDTs) installed at 90° to each other to measure displacement during expansion. Two soils were selected for testing: kaolinite and a uniform fine sand. Laboratory testing established baseline material properties for comparison with pressuremeter results. Kaolinite was tested using unconsolidated undrained (UU) triaxial tests to determine undrained shear strength (s_u) and secant shear modulus (G_s). For the sand, routine characterization included grain size distributions, a soil water characteristic curve, and specific gravity, while shear strength was assessed via direct shear (DS), direct simple shear (DSS), ring shear (RS), and consolidated undrained (CU) triaxial tests to estimate the critical state friction angle (\\phi_{cs}) and G_s. Proof of concept testing on both cohesive and cohesionless soils measured pressure-expansion curves that could be interpreted and compared to the laboratory results. Theoretical spherical cavity expansion models were fit to the measured curves, confirming that all three probes exhibited behaviour consistent with spherical expansion. Challenges were encountered capturing contraction during unload-reload cycles with the UWA and LVDT probes, limiting the ability to interpret the linear and non-linear shear moduli. The LVDT probe effectively captured expansion data, but achieved a maximum cavity strain of only 12% to 13%, falling short of the 20% target. Discrepancies between the two strain arms, difficulties in capturing contraction, possible friction between the arms and the probe body, or damage to one of the sensors were identified as contributing factors. Recommendations for future probe design iterations are provided to address these limitations."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["The Development of a Laboratory Scale Pressuremeter for use in Loose Sands"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Elwood, David"],"dc:contributor.committeemember":["Hawkes, Christopher","Fleming, Ian"],"dc:creator":["Wenz, Matthew"],"dc:date.accessioned":["2026-01-14T21:01:54Z"],"dc:date.available":["2026-01-14T21:01:54Z"],"dc:date.copyright":["2025"],"dc:date.created":["2026-05"],"dc:date.issued":["2026-01-14"],"dc:date.submitted":["May 2026"],"dc:date.updated":["2026-01-14T21:01:55Z"],"dc:description.abstract":["This study aimed to develop a laboratory-scale pressuremeter capable of applying a minimum 20% cavity strain to fully capture the shearing behaviour of a loose sand. Proof of concept testing was conducted on three pressuremeter probes: the original University of Western Australia (UWA) probe (Johnston et al., 2013), a clone of this probe (USask probe) to reduce the risk of damage, and a newly designed probe incorporating two linear variable differential transducers (LVDTs) installed at 90° to each other to measure displacement during expansion. Two soils were selected for testing: kaolinite and a uniform fine sand. Laboratory testing established baseline material properties for comparison with pressuremeter results. Kaolinite was tested using unconsolidated undrained (UU) triaxial tests to determine undrained shear strength (s_u) and secant shear modulus (G_s). For the sand, routine characterization included grain size distributions, a soil water characteristic curve, and specific gravity, while shear strength was assessed via direct shear (DS), direct simple shear (DSS), ring shear (RS), and consolidated undrained (CU) triaxial tests to estimate the critical state friction angle (\\phi_{cs}) and G_s. Proof of concept testing on both cohesive and cohesionless soils measured pressure-expansion curves that could be interpreted and compared to the laboratory results. Theoretical spherical cavity expansion models were fit to the measured curves, confirming that all three probes exhibited behaviour consistent with spherical expansion. Challenges were encountered capturing contraction during unload-reload cycles with the UWA and LVDT probes, limiting the ability to interpret the linear and non-linear shear moduli. The LVDT probe effectively captured expansion data, but achieved a maximum cavity strain of only 12% to 13%, falling short of the 20% target. Discrepancies between the two strain arms, difficulties in capturing contraction, possible friction between the arms and the probe body, or damage to one of the sensors were identified as contributing factors. Recommendations for future probe design iterations are provided to address these limitations."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/10388/17776"],"dc:language.iso":["en"],"dc:subject":["In-situ testing","Laboratory testing","Pressuremeter","Loose Sands"],"dc:title":["The Development of a Laboratory Scale Pressuremeter for use in Loose Sands"],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"thesis:degree_department":["Civil and Geological Engineering"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science (M.Sc.)"],"thesis:institution_name":["University of Saskatchewan"]},"updated_at":"2026-11-19T10:30:48Z"}