{"id":{"repo_id":"sask","oai_identifier":"oai:harvest.usask.ca:10388/18090"},"canonical_url":"https://search.ndltd.org/etd/sask/oai:harvest.usask.ca:10388/18090","repository":{"repo_id":"sask","name":"University of Saskatchewan","base_url":"https://harvest.usask.ca/server/oai/request"},"display":{"title":"FROST-FREE AIR-SOURCE HEAT PUMPS FOR SUSTAINABLE HEATING IN COLD CLIMATES","abstract":"Emissions from building heating systems account for 11% of global greenhouse gas (GHG) emissions. Replacing fossil-fuel-based heating systems with electricity-powered air-source heat pumps (ASHPs) can substantially reduce GHG emissions, particularly in regions where electricity is generated from low-emission sources. ASHPs can extract thermal energy from the ambient air and deliver it indoors, while operating at coefficients of performance (COP) of 1.5 to 3.0. However, ASHP performance is plagued by frosting and high refrigerant discharge temperatures in cold climates. Frosting is a phenomenon where moisture in the ambient air freezes on the outdoor unit (i.e., the evaporator) of an ASHP. In this thesis, the impacts of frosting and high discharge temperatures are evaluated in 45 Canadian cities. It is found that frosting is the major problem in the most populous regions of Canada with large conditioned floor space, and that frosting can increase energy consumption of ASHPs by up to 35%. To prevent frosting, this thesis proposes a liquid-to-air membrane energy exchanger (LAMEE) integrated with an ASHP to create a frost-free air-source heat pump called the LAMEE-HP. LAMEEs can simultaneously cool and dry air, thereby lowering the dew point temperature of the air flowing through the LAMEE. If the dew point is sufficiently reduced, frosting can be prevented. In a LAMEE-HP, the LAMEE serves as the outdoor unit instead of a traditional sensible-only evaporator to help reduce or prevent frosting. To evaluate the performance of a LAMEE HP, an analytical model called the coupled 𝜖-NTU method is developed and assessed for estimating heat and mass transfer rates in a LAMEE. Frosting limits for LAMEEs are defined to understand the conditions under which a LAMEE would remain frost-free. The main contribution of this thesis is a conceptual proof supported by numerical evidence that a LAMEE-HP can operate without frosting under any climatic condition when appropriately designed. The LAMEE-HP can also humidify indoor spaces. Simulation results in the thesis show that a LAMEE HP has, on average, a 50% higher COP than a standard ASHP under typical conditions that lead to frosting, i.e., at outdoor air temperatures between 5°C and -15°C. Annual energy savings from using a LAMEE-HP compared to a standard ASHP ranged from 12% in Saskatoon to 28% in Toronto and 35% in Vancouver, suggesting that LAMEE-HPs can reduce GHG emissions and heating costs in cold climates.","abstract_html":"Emissions from building heating systems account for 11% of global greenhouse gas (GHG) emissions. Replacing fossil-fuel-based heating systems with electricity-powered air-source heat pumps (ASHPs) can substantially reduce GHG emissions, particularly in regions where electricity is generated from low-emission sources. ASHPs can extract thermal energy from the ambient air and deliver it indoors, while operating at coefficients of performance (COP) of 1.5 to 3.0. However, ASHP performance is plagued by frosting and high refrigerant discharge temperatures in cold climates. Frosting is a phenomenon where moisture in the ambient air freezes on the outdoor unit (i.e., the evaporator) of an ASHP. In this thesis, the impacts of frosting and high discharge temperatures are evaluated in 45 Canadian cities. It is found that frosting is the major problem in the most populous regions of Canada with large conditioned floor space, and that frosting can increase energy consumption of ASHPs by up to 35%. To prevent frosting, this thesis proposes a liquid-to-air membrane energy exchanger (LAMEE) integrated with an ASHP to create a frost-free air-source heat pump called the LAMEE-HP. LAMEEs can simultaneously cool and dry air, thereby lowering the dew point temperature of the air flowing through the LAMEE. If the dew point is sufficiently reduced, frosting can be prevented. In a LAMEE-HP, the LAMEE serves as the outdoor unit instead of a traditional sensible-only evaporator to help reduce or prevent frosting. To evaluate the performance of a LAMEE HP, an analytical model called the coupled 𝜖-NTU method is developed and assessed for estimating heat and mass transfer rates in a LAMEE. Frosting limits for LAMEEs are defined to understand the conditions under which a LAMEE would remain frost-free. The main contribution of this thesis is a conceptual proof supported by numerical evidence that a LAMEE-HP can operate without frosting under any climatic condition when appropriately designed. The LAMEE-HP can also humidify indoor spaces. Simulation results in the thesis show that a LAMEE HP has, on average, a 50% higher COP than a standard ASHP under typical conditions that lead to frosting, i.e., at outdoor air temperatures between 5°C and -15°C. Annual energy savings from using a LAMEE-HP compared to a standard ASHP ranged from 12% in Saskatoon to 28% in Toronto and 35% in Vancouver, suggesting that LAMEE-HPs can reduce GHG emissions and heating costs in cold climates.","abstract_has_math":false,"creators":["Gollamudi, Siddhartha"],"institution":"University of Saskatchewan","degree_name":"Doctor of Philosophy (Ph.D.)","degree_level":"Doctoral","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Simonson, Carey"],"committee_chairs":[],"committee_members":["Bugg, James D.","Baik, Oon-Doo","Bernier, Michel","Tabil, Lope"],"year":2026,"date_issued":"2026-03-20","date_published":"2026-03-20","updated_at":"2026-11-19T10:13:57Z","subjects":["Frost-free air-source heat pump, cold climate heat pumps, sustainable heating systems, greenhouse gas emission reduction, frost-free exchangers, liquid-to-air membrane energy exchangers."],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10388/18090","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10388/18090","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Asask%3Aoai%3Aharvest.usask.ca%3A10388%2F18090","prefix":"oai_dc"},"source_record":{"url":"https://harvest.usask.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aharvest.usask.ca%3A10388%2F18090","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Simonson, Carey"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Bugg, James D.","Baik, Oon-Doo","Bernier, Michel","Tabil, Lope"]},{"key":"dc:creator","label":"Author","values":["Gollamudi, Siddhartha"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-03-20T16:29:09Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-03-20T16:29:09Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2026"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2026-03"]},{"key":"dc:date.issued","label":"Date","values":["2026-03-20"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["March 2026"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-03-20T16:29:09Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_department","label":"Department","values":["Mechanical Engineering"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (Ph.D.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Saskatchewan"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Frost-free air-source heat pump, cold climate heat pumps, sustainable heating systems, greenhouse gas emission reduction, frost-free exchangers, liquid-to-air membrane energy exchangers."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10388/18090"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Emissions from building heating systems account for 11% of global greenhouse gas (GHG) emissions. Replacing fossil-fuel-based heating systems with electricity-powered air-source heat pumps (ASHPs) can substantially reduce GHG emissions, particularly in regions where electricity is generated from low-emission sources. ASHPs can extract thermal energy from the ambient air and deliver it indoors, while operating at coefficients of performance (COP) of 1.5 to 3.0. However, ASHP performance is plagued by frosting and high refrigerant discharge temperatures in cold climates. Frosting is a phenomenon where moisture in the ambient air freezes on the outdoor unit (i.e., the evaporator) of an ASHP. In this thesis, the impacts of frosting and high discharge temperatures are evaluated in 45 Canadian cities. It is found that frosting is the major problem in the most populous regions of Canada with large conditioned floor space, and that frosting can increase energy consumption of ASHPs by up to 35%. To prevent frosting, this thesis proposes a liquid-to-air membrane energy exchanger (LAMEE) integrated with an ASHP to create a frost-free air-source heat pump called the LAMEE-HP. LAMEEs can simultaneously cool and dry air, thereby lowering the dew point temperature of the air flowing through the LAMEE. If the dew point is sufficiently reduced, frosting can be prevented. In a LAMEE-HP, the LAMEE serves as the outdoor unit instead of a traditional sensible-only evaporator to help reduce or prevent frosting. To evaluate the performance of a LAMEE HP, an analytical model called the coupled 𝜖-NTU method is developed and assessed for estimating heat and mass transfer rates in a LAMEE. Frosting limits for LAMEEs are defined to understand the conditions under which a LAMEE would remain frost-free. The main contribution of this thesis is a conceptual proof supported by numerical evidence that a LAMEE-HP can operate without frosting under any climatic condition when appropriately designed. The LAMEE-HP can also humidify indoor spaces. Simulation results in the thesis show that a LAMEE HP has, on average, a 50% higher COP than a standard ASHP under typical conditions that lead to frosting, i.e., at outdoor air temperatures between 5°C and -15°C. Annual energy savings from using a LAMEE-HP compared to a standard ASHP ranged from 12% in Saskatoon to 28% in Toronto and 35% in Vancouver, suggesting that LAMEE-HPs can reduce GHG emissions and heating costs in cold climates."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["FROST-FREE AIR-SOURCE HEAT PUMPS FOR SUSTAINABLE HEATING IN COLD CLIMATES"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Simonson, Carey"],"dc:contributor.committeemember":["Bugg, James D.","Baik, Oon-Doo","Bernier, Michel","Tabil, Lope"],"dc:creator":["Gollamudi, Siddhartha"],"dc:date.accessioned":["2026-03-20T16:29:09Z"],"dc:date.available":["2026-03-20T16:29:09Z"],"dc:date.copyright":["2026"],"dc:date.created":["2026-03"],"dc:date.issued":["2026-03-20"],"dc:date.submitted":["March 2026"],"dc:date.updated":["2026-03-20T16:29:09Z"],"dc:description.abstract":["Emissions from building heating systems account for 11% of global greenhouse gas (GHG) emissions. Replacing fossil-fuel-based heating systems with electricity-powered air-source heat pumps (ASHPs) can substantially reduce GHG emissions, particularly in regions where electricity is generated from low-emission sources. ASHPs can extract thermal energy from the ambient air and deliver it indoors, while operating at coefficients of performance (COP) of 1.5 to 3.0. However, ASHP performance is plagued by frosting and high refrigerant discharge temperatures in cold climates. Frosting is a phenomenon where moisture in the ambient air freezes on the outdoor unit (i.e., the evaporator) of an ASHP. In this thesis, the impacts of frosting and high discharge temperatures are evaluated in 45 Canadian cities. It is found that frosting is the major problem in the most populous regions of Canada with large conditioned floor space, and that frosting can increase energy consumption of ASHPs by up to 35%. To prevent frosting, this thesis proposes a liquid-to-air membrane energy exchanger (LAMEE) integrated with an ASHP to create a frost-free air-source heat pump called the LAMEE-HP. LAMEEs can simultaneously cool and dry air, thereby lowering the dew point temperature of the air flowing through the LAMEE. If the dew point is sufficiently reduced, frosting can be prevented. In a LAMEE-HP, the LAMEE serves as the outdoor unit instead of a traditional sensible-only evaporator to help reduce or prevent frosting. To evaluate the performance of a LAMEE HP, an analytical model called the coupled 𝜖-NTU method is developed and assessed for estimating heat and mass transfer rates in a LAMEE. Frosting limits for LAMEEs are defined to understand the conditions under which a LAMEE would remain frost-free. The main contribution of this thesis is a conceptual proof supported by numerical evidence that a LAMEE-HP can operate without frosting under any climatic condition when appropriately designed. The LAMEE-HP can also humidify indoor spaces. Simulation results in the thesis show that a LAMEE HP has, on average, a 50% higher COP than a standard ASHP under typical conditions that lead to frosting, i.e., at outdoor air temperatures between 5°C and -15°C. Annual energy savings from using a LAMEE-HP compared to a standard ASHP ranged from 12% in Saskatoon to 28% in Toronto and 35% in Vancouver, suggesting that LAMEE-HPs can reduce GHG emissions and heating costs in cold climates."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/10388/18090"],"dc:language.iso":["en"],"dc:subject":["Frost-free air-source heat pump, cold climate heat pumps, sustainable heating systems, greenhouse gas emission reduction, frost-free exchangers, liquid-to-air membrane energy exchangers."],"dc:title":["FROST-FREE AIR-SOURCE HEAT PUMPS FOR SUSTAINABLE HEATING IN COLD CLIMATES"],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"thesis:degree_department":["Mechanical Engineering"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Doctor of Philosophy (Ph.D.)"],"thesis:institution_name":["University of Saskatchewan"]},"updated_at":"2026-11-19T10:13:57Z"}