{"id":{"repo_id":"sask","oai_identifier":"oai:harvest.usask.ca:10388/19166"},"canonical_url":"https://search.ndltd.org/etd/sask/oai:harvest.usask.ca:10388/19166","repository":{"repo_id":"sask","name":"University of Saskatchewan","base_url":"https://harvest.usask.ca/server/oai/request"},"display":{"title":"Influence of web geometry on the out-of-plane shear capacity of concrete masonry walls","abstract":"The use of masonry for structural applications has declined in the past several decades as other materials have become lower cost and more energy efficient. Efforts are therefore being made to maintain masonry as a competitive building material through optimization of concrete masonry unit (CMU) geometry. The governing standards for CMU geometry in Canada and the United States, being CSA A165-14 and ASTM C90-24 respectively, differ in their requirements for minimum web geometry: ASTM C90 permits webs that are both thinner and shorter than those allowed by CSA A165. Reductions to web geometry have several benefits, including decreased CMU weight and improvements to the thermal performance of masonry. However, webs are responsible for resisting shear stresses and so decreased web geometry may result in corresponding reductions to the capacity of masonry assemblages. A research program has therefore been initiated to evaluate the influence of web geometry on the structural performance of masonry and so determine whether reductions can be made to the requirements of CSA A165. The influence of web geometry on the out-of-plane shear capacity of masonry walls was evaluated experimentally as part of this research program and is presented herein. Thirty-one walls were constructed using four different CMU types with varying web geometries and subject to four-point out-of-plane loading. All walls were reinforced with unbonded steel bars to isolate the influence of web geometry. Applied loads and deflections were recorded during testing to establish the shear capacity of the walls and their load-deflection response. Three failure mechanisms were observed: flexure, diagonal shear, and web splitting shear. Results indicated that shear capacity is a function of normalized web area. However, reductions in shear capacity are unlikely to impact structural design and so it is recommended that the requirements of CSA A165 be modified to allow for the use of CMUs with reduced web geometry in Canada.","abstract_html":"The use of masonry for structural applications has declined in the past several decades as other materials have become lower cost and more energy efficient. Efforts are therefore being made to maintain masonry as a competitive building material through optimization of concrete masonry unit (CMU) geometry. The governing standards for CMU geometry in Canada and the United States, being CSA A165-14 and ASTM C90-24 respectively, differ in their requirements for minimum web geometry: ASTM C90 permits webs that are both thinner and shorter than those allowed by CSA A165. Reductions to web geometry have several benefits, including decreased CMU weight and improvements to the thermal performance of masonry. However, webs are responsible for resisting shear stresses and so decreased web geometry may result in corresponding reductions to the capacity of masonry assemblages. A research program has therefore been initiated to evaluate the influence of web geometry on the structural performance of masonry and so determine whether reductions can be made to the requirements of CSA A165. The influence of web geometry on the out-of-plane shear capacity of masonry walls was evaluated experimentally as part of this research program and is presented herein. Thirty-one walls were constructed using four different CMU types with varying web geometries and subject to four-point out-of-plane loading. All walls were reinforced with unbonded steel bars to isolate the influence of web geometry. Applied loads and deflections were recorded during testing to establish the shear capacity of the walls and their load-deflection response. Three failure mechanisms were observed: flexure, diagonal shear, and web splitting shear. Results indicated that shear capacity is a function of normalized web area. However, reductions in shear capacity are unlikely to impact structural design and so it is recommended that the requirements of CSA A165 be modified to allow for the use of CMUs with reduced web geometry in Canada.","abstract_has_math":false,"creators":["Pahl, Will Robinson"],"institution":"University of Saskatchewan","degree_name":"Master of Science (M.Sc.)","degree_level":"Masters","degree_discipline":"Civil Engineering","degree_department":"Civil and Geological Engineering","school":null,"contributors":[],"advisors":["Feldman, Lisa R"],"committee_chairs":[],"committee_members":["Wegner, Leon D","Thompson, Jason J"],"year":2026,"date_issued":"2026-09-09","date_published":"2026-09-09","updated_at":"2026-11-19T10:01:37Z","subjects":["Concrete masonry, shear, block geometry, out-of-plane loading"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0009-0007-9706-6418"],"render_values":[{"text":"0009-0007-9706-6418","href":"https://orcid.org/0009-0007-9706-6418","code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/10388/19166","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10388/19166","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://harvest.usask.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aharvest.usask.ca%3A10388%2F19166","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Feldman, Lisa R"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Wegner, Leon D","Thompson, Jason J"]},{"key":"dc:creator","label":"Author","values":["Pahl, Will Robinson"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0009-0007-9706-6418"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-09-09T15:50:09Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2026"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2026-11"]},{"key":"dc:date.issued","label":"Date","values":["2026-09-09"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["November 2026"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-09-09T15:50:12Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_department","label":"Department","values":["Civil and Geological Engineering"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.Sc.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Saskatchewan"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Concrete masonry, shear, block geometry, out-of-plane loading"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10388/19166"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The use of masonry for structural applications has declined in the past several decades as other materials have become lower cost and more energy efficient. Efforts are therefore being made to maintain masonry as a competitive building material through optimization of concrete masonry unit (CMU) geometry. The governing standards for CMU geometry in Canada and the United States, being CSA A165-14 and ASTM C90-24 respectively, differ in their requirements for minimum web geometry: ASTM C90 permits webs that are both thinner and shorter than those allowed by CSA A165. Reductions to web geometry have several benefits, including decreased CMU weight and improvements to the thermal performance of masonry. However, webs are responsible for resisting shear stresses and so decreased web geometry may result in corresponding reductions to the capacity of masonry assemblages. A research program has therefore been initiated to evaluate the influence of web geometry on the structural performance of masonry and so determine whether reductions can be made to the requirements of CSA A165. The influence of web geometry on the out-of-plane shear capacity of masonry walls was evaluated experimentally as part of this research program and is presented herein. Thirty-one walls were constructed using four different CMU types with varying web geometries and subject to four-point out-of-plane loading. All walls were reinforced with unbonded steel bars to isolate the influence of web geometry. Applied loads and deflections were recorded during testing to establish the shear capacity of the walls and their load-deflection response. Three failure mechanisms were observed: flexure, diagonal shear, and web splitting shear. Results indicated that shear capacity is a function of normalized web area. However, reductions in shear capacity are unlikely to impact structural design and so it is recommended that the requirements of CSA A165 be modified to allow for the use of CMUs with reduced web geometry in Canada."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Influence of web geometry on the out-of-plane shear capacity of concrete masonry walls"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Feldman, Lisa R"],"dc:contributor.committeemember":["Wegner, Leon D","Thompson, Jason J"],"dc:creator":["Pahl, Will Robinson"],"dc:date.accessioned":["2026-09-09T15:50:09Z"],"dc:date.copyright":["2026"],"dc:date.created":["2026-11"],"dc:date.issued":["2026-09-09"],"dc:date.submitted":["November 2026"],"dc:date.updated":["2026-09-09T15:50:12Z"],"dc:description.abstract":["The use of masonry for structural applications has declined in the past several decades as other materials have become lower cost and more energy efficient. Efforts are therefore being made to maintain masonry as a competitive building material through optimization of concrete masonry unit (CMU) geometry. The governing standards for CMU geometry in Canada and the United States, being CSA A165-14 and ASTM C90-24 respectively, differ in their requirements for minimum web geometry: ASTM C90 permits webs that are both thinner and shorter than those allowed by CSA A165. Reductions to web geometry have several benefits, including decreased CMU weight and improvements to the thermal performance of masonry. However, webs are responsible for resisting shear stresses and so decreased web geometry may result in corresponding reductions to the capacity of masonry assemblages. A research program has therefore been initiated to evaluate the influence of web geometry on the structural performance of masonry and so determine whether reductions can be made to the requirements of CSA A165. The influence of web geometry on the out-of-plane shear capacity of masonry walls was evaluated experimentally as part of this research program and is presented herein. Thirty-one walls were constructed using four different CMU types with varying web geometries and subject to four-point out-of-plane loading. All walls were reinforced with unbonded steel bars to isolate the influence of web geometry. Applied loads and deflections were recorded during testing to establish the shear capacity of the walls and their load-deflection response. Three failure mechanisms were observed: flexure, diagonal shear, and web splitting shear. Results indicated that shear capacity is a function of normalized web area. However, reductions in shear capacity are unlikely to impact structural design and so it is recommended that the requirements of CSA A165 be modified to allow for the use of CMUs with reduced web geometry in Canada."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/10388/19166"],"dc:language.iso":["en"],"dc:subject":["Concrete masonry, shear, block geometry, out-of-plane loading"],"dc:title":["Influence of web geometry on the out-of-plane shear capacity of concrete masonry walls"],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"person:identifier.orcid":["0009-0007-9706-6418"],"thesis:degree_department":["Civil and Geological Engineering"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science (M.Sc.)"],"thesis:institution_name":["University of Saskatchewan"]},"updated_at":"2026-11-19T10:01:37Z"}