{"id":{"repo_id":"sask","oai_identifier":"oai:harvest.usask.ca:10388/19192"},"canonical_url":"https://search.ndltd.org/etd/sask/oai:harvest.usask.ca:10388/19192","repository":{"repo_id":"sask","name":"University of Saskatchewan","base_url":"https://harvest.usask.ca/server/oai/request"},"display":{"title":"Sub-component Level Modeling of a Variable Displacement Axial Piston Pump","abstract":"The variable displacement axial piston pump is widely used as a power transfer device for its combination of relatively high operating pressure and controllable variable flow rate. Problems still exist in the design stage of the pump, the design stage of the controller, and in determination of the performance of the pump. In order to examine and solve these problems without the time and expense associated with building numerous prototypes, it is necessary to develop a mathematical model with predicts the behaviour of the pump given a control signal and a load condition. Subsequent verification of such a model is made difficult by the lack of a simple and practical measurement method for a parameter which reflects the internal dynamics of the pump. As a first step to addressing these issues, an extensive literature review was carried out. From this literature review, the mathematical developments relevant to the mathematical modeling of pumps of this type were identified. This formed the basis for the development of the describing equations for the pump. The model was developed to include the control apparatus of the pump, which in the case of the test pump, was a control piston. It was decided that the pressure in the control piston may act as transducer for the motion of the swashplate. In that case, the control piston pressure would provide a simple yet non-intrusive measurement reflecting the internal dynamics of the pump. An apparatus was designed such that the ability of the model to predict the behaviour of the pump could be tested. This required that the model and the experimental apparatus were operating under the same conditions. A modeling methodology was adopted and the apparatus was appropriately instrumented to ensure that this was the case. The results of the experimental and simulation pump behaviour were examined. The control piston pressure waveforms were compared both for correlation, which would indicate correct modeling of the pump, and discrepancies, which would indicate oversimplification of the model or omission of relevant affects within the pump.","abstract_html":"The variable displacement axial piston pump is widely used as a power transfer device for its combination of relatively high operating pressure and controllable variable flow rate. Problems still exist in the design stage of the pump, the design stage of the controller, and in determination of the performance of the pump. In order to examine and solve these problems without the time and expense associated with building numerous prototypes, it is necessary to develop a mathematical model with predicts the behaviour of the pump given a control signal and a load condition. Subsequent verification of such a model is made difficult by the lack of a simple and practical measurement method for a parameter which reflects the internal dynamics of the pump. As a first step to addressing these issues, an extensive literature review was carried out. From this literature review, the mathematical developments relevant to the mathematical modeling of pumps of this type were identified. This formed the basis for the development of the describing equations for the pump. The model was developed to include the control apparatus of the pump, which in the case of the test pump, was a control piston. It was decided that the pressure in the control piston may act as transducer for the motion of the swashplate. In that case, the control piston pressure would provide a simple yet non-intrusive measurement reflecting the internal dynamics of the pump. An apparatus was designed such that the ability of the model to predict the behaviour of the pump could be tested. This required that the model and the experimental apparatus were operating under the same conditions. A modeling methodology was adopted and the apparatus was appropriately instrumented to ensure that this was the case. The results of the experimental and simulation pump behaviour were examined. The control piston pressure waveforms were compared both for correlation, which would indicate correct modeling of the pump, and discrepancies, which would indicate oversimplification of the model or omission of relevant affects within the pump.","abstract_has_math":false,"creators":["Dobchuk, Jeffery W."],"institution":"University of Saskatchewan","degree_name":"Master of Science (M.Sc.)","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Burton, R. T.","Nikiforuk, P. N."],"committee_chairs":[],"committee_members":[],"year":2000,"date_issued":"2000-12","date_published":"2000-12","updated_at":"2026-11-19T10:31:01Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10388/19192","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10388/19192","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Asask%3Aoai%3Aharvest.usask.ca%3A10388%2F19192","prefix":"oai_dc"},"source_record":{"url":"https://harvest.usask.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aharvest.usask.ca%3A10388%2F19192","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Burton, R. T.","Nikiforuk, P. N."]},{"key":"dc:creator","label":"Author","values":["Dobchuk, Jeffery W."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-09-14T20:04:46Z"]},{"key":"dc:date.issued","label":"Date","values":["2000-12"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2000"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Mechanical Engineering"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.Sc.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Saskatchewan"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10388/19192"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The variable displacement axial piston pump is widely used as a power transfer device for its combination of relatively high operating pressure and controllable variable flow rate. Problems still exist in the design stage of the pump, the design stage of the controller, and in determination of the performance of the pump. In order to examine and solve these problems without the time and expense associated with building numerous prototypes, it is necessary to develop a mathematical model with predicts the behaviour of the pump given a control signal and a load condition. Subsequent verification of such a model is made difficult by the lack of a simple and practical measurement method for a parameter which reflects the internal dynamics of the pump. As a first step to addressing these issues, an extensive literature review was carried out. From this literature review, the mathematical developments relevant to the mathematical modeling of pumps of this type were identified. This formed the basis for the development of the describing equations for the pump. The model was developed to include the control apparatus of the pump, which in the case of the test pump, was a control piston. It was decided that the pressure in the control piston may act as transducer for the motion of the swashplate. In that case, the control piston pressure would provide a simple yet non-intrusive measurement reflecting the internal dynamics of the pump. An apparatus was designed such that the ability of the model to predict the behaviour of the pump could be tested. This required that the model and the experimental apparatus were operating under the same conditions. A modeling methodology was adopted and the apparatus was appropriately instrumented to ensure that this was the case. The results of the experimental and simulation pump behaviour were examined. The control piston pressure waveforms were compared both for correlation, which would indicate correct modeling of the pump, and discrepancies, which would indicate oversimplification of the model or omission of relevant affects within the pump."]},{"key":"dc:title","label":"Title","values":["Sub-component Level Modeling of a Variable Displacement Axial Piston Pump"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Burton, R. T.","Nikiforuk, P. N."],"dc:creator":["Dobchuk, Jeffery W."],"dc:date.accessioned":["2026-09-14T20:04:46Z"],"dc:date.issued":["2000-12"],"dc:date.submitted":["December 2000"],"dc:description.abstract":["The variable displacement axial piston pump is widely used as a power transfer device for its combination of relatively high operating pressure and controllable variable flow rate. Problems still exist in the design stage of the pump, the design stage of the controller, and in determination of the performance of the pump. In order to examine and solve these problems without the time and expense associated with building numerous prototypes, it is necessary to develop a mathematical model with predicts the behaviour of the pump given a control signal and a load condition. Subsequent verification of such a model is made difficult by the lack of a simple and practical measurement method for a parameter which reflects the internal dynamics of the pump. As a first step to addressing these issues, an extensive literature review was carried out. From this literature review, the mathematical developments relevant to the mathematical modeling of pumps of this type were identified. This formed the basis for the development of the describing equations for the pump. The model was developed to include the control apparatus of the pump, which in the case of the test pump, was a control piston. It was decided that the pressure in the control piston may act as transducer for the motion of the swashplate. In that case, the control piston pressure would provide a simple yet non-intrusive measurement reflecting the internal dynamics of the pump. An apparatus was designed such that the ability of the model to predict the behaviour of the pump could be tested. This required that the model and the experimental apparatus were operating under the same conditions. A modeling methodology was adopted and the apparatus was appropriately instrumented to ensure that this was the case. The results of the experimental and simulation pump behaviour were examined. The control piston pressure waveforms were compared both for correlation, which would indicate correct modeling of the pump, and discrepancies, which would indicate oversimplification of the model or omission of relevant affects within the pump."],"dc:identifier.uri":["https://hdl.handle.net/10388/19192"],"dc:title":["Sub-component Level Modeling of a Variable Displacement Axial Piston Pump"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Mechanical Engineering"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science (M.Sc.)"],"thesis:institution_name":["University of Saskatchewan"]},"updated_at":"2026-11-19T10:31:01Z"}