{"id":{"repo_id":"sask","oai_identifier":"oai:harvest.usask.ca:10388/7775"},"canonical_url":"https://search.ndltd.org/etd/sask/oai:harvest.usask.ca:10388/7775","repository":{"repo_id":"sask","name":"University of Saskatchewan","base_url":"https://harvest.usask.ca/server/oai/request"},"display":{"title":"Hydrogen Storage in Ni/graphene and Pd/graphene Nanomaterials","abstract":"Hydrogen is a promising energy carrier that could be an alternative to the traditional carbon based fuels. Hydrogen storage in the Ni/graphene and Pd/graphene systems was investigated in the present work using Thermogravimetric Analysis (TGA). A laboratory apparatus was designed, built and applied for hydrogenation under pressure. Novel synthesis methods were developed to synthesize the graphene-based composites. Multiple characterizations have been performed to understand the sorbent structures, including the component determination and distribution, chemical state, electronic structure and metal-graphene interfaces. The hydrogen storage behavior was determined, and a hypothesis was proposed to explain the hydrogen performance in the sorbents. The Ni/graphene (5 at.% Ni, atomic percentage; 100 at.% : Ni + C) composite, charged with H2 pressure under 1 and 60 bar desorbed 0.14 wt.% H2 and 1.18 wt.%, respectively, in a TGA apparatus under a flow of argon, at room temperature. The hydrogen release could occur at an operating temperature below 150°C and was completed at 250°C. The Pd/graphene (1 at.% Pd, 100 at.% : Pd + C) composite, charged under H2 pressure of 50 and 60 bar released 6.7 and 8.67 wt.% H2, respectively, in a TGA apparatus under a flow of argon, at room temperature. The 5%Pd/graphene (5 at.% Pd, 100 at.% : Pd + C) composite charged under 60 bar H2 and dehydrogenated under the same conditions in a TGA apparatus, released 7.16 wt.% H2. The composites could discharge hydrogen below 100°C and complete the process up to 200°C. The Pd/graphene system releases relatively high hydrogen storage capacity in TGA.","abstract_html":"Hydrogen is a promising energy carrier that could be an alternative to the traditional carbon based fuels. Hydrogen storage in the Ni/graphene and Pd/graphene systems was investigated in the present work using Thermogravimetric Analysis (TGA). A laboratory apparatus was designed, built and applied for hydrogenation under pressure. Novel synthesis methods were developed to synthesize the graphene-based composites. Multiple characterizations have been performed to understand the sorbent structures, including the component determination and distribution, chemical state, electronic structure and metal-graphene interfaces. The hydrogen storage behavior was determined, and a hypothesis was proposed to explain the hydrogen performance in the sorbents. The Ni/graphene (5 at.% Ni, atomic percentage; 100 at.% : Ni + C) composite, charged with H2 pressure under 1 and 60 bar desorbed 0.14 wt.% H2 and 1.18 wt.%, respectively, in a TGA apparatus under a flow of argon, at room temperature. The hydrogen release could occur at an operating temperature below 150°C and was completed at 250°C. The Pd/graphene (1 at.% Pd, 100 at.% : Pd + C) composite, charged under H2 pressure of 50 and 60 bar released 6.7 and 8.67 wt.% H2, respectively, in a TGA apparatus under a flow of argon, at room temperature. The 5%Pd/graphene (5 at.% Pd, 100 at.% : Pd + C) composite charged under 60 bar H2 and dehydrogenated under the same conditions in a TGA apparatus, released 7.16 wt.% H2. The composites could discharge hydrogen below 100°C and complete the process up to 200°C. The Pd/graphene system releases relatively high hydrogen storage capacity in TGA.","abstract_has_math":false,"creators":["Zhou, Chunyu"],"institution":"University of Saskatchewan","degree_name":"Doctor of Philosophy (Ph.D.)","degree_level":"Doctoral","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Szpunar, Jerzy A"],"committee_chairs":[],"committee_members":["Hu, Yongfeng","Wang, Hui","Oguocha, Ikechukwuka","Szyszkowski, Walerian"],"year":2017,"date_issued":"2017-03-07","date_published":"2017-03-07","updated_at":"2026-11-19T10:31:01Z","subjects":["Hydrogen, Ni/graphene, Pd/graphene"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000-0003-2053-7086"],"render_values":[{"text":"0000-0003-2053-7086","href":"https://orcid.org/0000-0003-2053-7086","code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/10388/7775","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10388/7775","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Asask%3Aoai%3Aharvest.usask.ca%3A10388%2F7775","prefix":"oai_dc"},"source_record":{"url":"https://harvest.usask.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aharvest.usask.ca%3A10388%2F7775","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Szpunar, Jerzy A"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Hu, Yongfeng","Wang, Hui","Oguocha, Ikechukwuka","Szyszkowski, Walerian"]},{"key":"dc:creator","label":"Author","values":["Zhou, Chunyu"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000-0003-2053-7086"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-03-07T19:39:10Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-03-07T19:39:10Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2016-12"]},{"key":"dc:date.issued","label":"Date","values":["2017-03-07"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2016"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2017-03-07T19:39:11Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_department","label":"Department","values":["Mechanical Engineering"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (Ph.D.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Saskatchewan"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Hydrogen, Ni/graphene, Pd/graphene"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10388/7775"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Hydrogen is a promising energy carrier that could be an alternative to the traditional carbon based fuels. Hydrogen storage in the Ni/graphene and Pd/graphene systems was investigated in the present work using Thermogravimetric Analysis (TGA). A laboratory apparatus was designed, built and applied for hydrogenation under pressure. Novel synthesis methods were developed to synthesize the graphene-based composites. Multiple characterizations have been performed to understand the sorbent structures, including the component determination and distribution, chemical state, electronic structure and metal-graphene interfaces. The hydrogen storage behavior was determined, and a hypothesis was proposed to explain the hydrogen performance in the sorbents. The Ni/graphene (5 at.% Ni, atomic percentage; 100 at.% : Ni + C) composite, charged with H2 pressure under 1 and 60 bar desorbed 0.14 wt.% H2 and 1.18 wt.%, respectively, in a TGA apparatus under a flow of argon, at room temperature. The hydrogen release could occur at an operating temperature below 150°C and was completed at 250°C. The Pd/graphene (1 at.% Pd, 100 at.% : Pd + C) composite, charged under H2 pressure of 50 and 60 bar released 6.7 and 8.67 wt.% H2, respectively, in a TGA apparatus under a flow of argon, at room temperature. The 5%Pd/graphene (5 at.% Pd, 100 at.% : Pd + C) composite charged under 60 bar H2 and dehydrogenated under the same conditions in a TGA apparatus, released 7.16 wt.% H2. The composites could discharge hydrogen below 100°C and complete the process up to 200°C. The Pd/graphene system releases relatively high hydrogen storage capacity in TGA."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Hydrogen Storage in Ni/graphene and Pd/graphene Nanomaterials"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Szpunar, Jerzy A"],"dc:contributor.committeemember":["Hu, Yongfeng","Wang, Hui","Oguocha, Ikechukwuka","Szyszkowski, Walerian"],"dc:creator":["Zhou, Chunyu"],"dc:date.accessioned":["2017-03-07T19:39:10Z"],"dc:date.available":["2017-03-07T19:39:10Z"],"dc:date.created":["2016-12"],"dc:date.issued":["2017-03-07"],"dc:date.submitted":["December 2016"],"dc:date.updated":["2017-03-07T19:39:11Z"],"dc:description.abstract":["Hydrogen is a promising energy carrier that could be an alternative to the traditional carbon based fuels. Hydrogen storage in the Ni/graphene and Pd/graphene systems was investigated in the present work using Thermogravimetric Analysis (TGA). A laboratory apparatus was designed, built and applied for hydrogenation under pressure. Novel synthesis methods were developed to synthesize the graphene-based composites. Multiple characterizations have been performed to understand the sorbent structures, including the component determination and distribution, chemical state, electronic structure and metal-graphene interfaces. The hydrogen storage behavior was determined, and a hypothesis was proposed to explain the hydrogen performance in the sorbents. The Ni/graphene (5 at.% Ni, atomic percentage; 100 at.% : Ni + C) composite, charged with H2 pressure under 1 and 60 bar desorbed 0.14 wt.% H2 and 1.18 wt.%, respectively, in a TGA apparatus under a flow of argon, at room temperature. The hydrogen release could occur at an operating temperature below 150°C and was completed at 250°C. The Pd/graphene (1 at.% Pd, 100 at.% : Pd + C) composite, charged under H2 pressure of 50 and 60 bar released 6.7 and 8.67 wt.% H2, respectively, in a TGA apparatus under a flow of argon, at room temperature. The 5%Pd/graphene (5 at.% Pd, 100 at.% : Pd + C) composite charged under 60 bar H2 and dehydrogenated under the same conditions in a TGA apparatus, released 7.16 wt.% H2. The composites could discharge hydrogen below 100°C and complete the process up to 200°C. The Pd/graphene system releases relatively high hydrogen storage capacity in TGA."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/10388/7775"],"dc:subject":["Hydrogen, Ni/graphene, Pd/graphene"],"dc:title":["Hydrogen Storage in Ni/graphene and Pd/graphene Nanomaterials"],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"person:identifier.orcid":["0000-0003-2053-7086"],"thesis:degree_department":["Mechanical Engineering"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Doctor of Philosophy (Ph.D.)"],"thesis:institution_name":["University of Saskatchewan"]},"updated_at":"2026-11-19T10:31:01Z"}