{"id":{"repo_id":"sask","oai_identifier":"oai:harvest.usask.ca:10388/8085"},"canonical_url":"https://search.ndltd.org/etd/sask/oai:harvest.usask.ca:10388/8085","repository":{"repo_id":"sask","name":"University of Saskatchewan","base_url":"https://harvest.usask.ca/server/oai/request"},"display":{"title":"MAGNETIC RESONANCE ELASTOGRAPHY FOR APPLICATIONS IN RADIATION THERAPY","abstract":"Magnetic resonance elastography (MRE) is an imaging technique that combines mechanical waves and magnetic resonance imaging (MRI) to determine the elastic properties of tissue. Because MRE is non-invasive, there is great potential and interest for its use in the detection of cancer. The first part of this thesis concentrates on parameter optimization and imaging quality of an MRE system. To do this, we developed a customized quality assurance phantom, and a series of quality control tests to characterize the MRE system. Our results demonstrated that through optimizing scan parameters, such as frequency and amplitude, MRE could provide a good qualitative elastogram for targets with different elasticity values and dimensions. The second part investigated the feasibility of integrating MRE into radiation therapy (RT) workflow. With the aid of a tissue-equivalent prostate phantom (embedded with three dominant intraprostatic lesions (DILs)), an MRE-integrated RT framework was developed. This framework contains a comprehensive scan protocol including Computed Tomography (CT) scan, combined MRI/MRE scans and a Volumetric Modulated Arc Therapy (VMAT) technique for treatment delivery. The results showed that using the comprehensive information could boost the MRE defined DILs to 84 Gy while keeping the remainder of the prostate to 78 Gy. Using a VMAT based technique allowed us to achieve a highly conformal plan (conformity index for the prostate and combined DILs was 0.98 and 0.91). Based on our feasibility study, we concluded that MRE data can be used for targeted radiation dose escalation. In summary, this thesis demonstrates that MRE is feasible for applications in radiation oncology.","abstract_html":"Magnetic resonance elastography (MRE) is an imaging technique that combines mechanical waves and magnetic resonance imaging (MRI) to determine the elastic properties of tissue. Because MRE is non-invasive, there is great potential and interest for its use in the detection of cancer. The first part of this thesis concentrates on parameter optimization and imaging quality of an MRE system. To do this, we developed a customized quality assurance phantom, and a series of quality control tests to characterize the MRE system. Our results demonstrated that through optimizing scan parameters, such as frequency and amplitude, MRE could provide a good qualitative elastogram for targets with different elasticity values and dimensions. The second part investigated the feasibility of integrating MRE into radiation therapy (RT) workflow. With the aid of a tissue-equivalent prostate phantom (embedded with three dominant intraprostatic lesions (DILs)), an MRE-integrated RT framework was developed. This framework contains a comprehensive scan protocol including Computed Tomography (CT) scan, combined MRI/MRE scans and a Volumetric Modulated Arc Therapy (VMAT) technique for treatment delivery. The results showed that using the comprehensive information could boost the MRE defined DILs to 84 Gy while keeping the remainder of the prostate to 78 Gy. Using a VMAT based technique allowed us to achieve a highly conformal plan (conformity index for the prostate and combined DILs was 0.98 and 0.91). Based on our feasibility study, we concluded that MRE data can be used for targeted radiation dose escalation. In summary, this thesis demonstrates that MRE is feasible for applications in radiation oncology.","abstract_has_math":false,"creators":["Cui, Lumeng 1991-"],"institution":"University of Saskatchewan","degree_name":"Master of Science (M.Sc.)","degree_level":"Masters","degree_discipline":"Biomedical Engineering","degree_department":"Biomedical Engineering","school":null,"contributors":[],"advisors":["Venugopal, Niranjan","Babyn, Paul","Bui, Francis"],"committee_chairs":[],"committee_members":["McWalter, Emily","Alexander, Andrew","Eramian, Mark"],"year":2017,"date_issued":"2017-09-13","date_published":"2017-09-13","updated_at":"2026-11-19T10:12:14Z","subjects":["MRE","MRI","Phantom","QA","Radiation Therapy"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10388/8085","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10388/8085","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://harvest.usask.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aharvest.usask.ca%3A10388%2F8085","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Venugopal, Niranjan","Babyn, Paul","Bui, Francis"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["McWalter, Emily","Alexander, Andrew","Eramian, Mark"]},{"key":"dc:creator","label":"Author","values":["Cui, Lumeng 1991-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-09-13T16:17:03Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-09-13T16:17:03Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2017-10"]},{"key":"dc:date.issued","label":"Date","values":["2017-09-13"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["October 2017"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2017-09-13T16:17:04Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_department","label":"Department","values":["Biomedical Engineering"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.Sc.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Saskatchewan"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["MRE","MRI","Phantom","QA","Radiation Therapy"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10388/8085"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Magnetic resonance elastography (MRE) is an imaging technique that combines mechanical waves and magnetic resonance imaging (MRI) to determine the elastic properties of tissue. Because MRE is non-invasive, there is great potential and interest for its use in the detection of cancer. The first part of this thesis concentrates on parameter optimization and imaging quality of an MRE system. To do this, we developed a customized quality assurance phantom, and a series of quality control tests to characterize the MRE system. Our results demonstrated that through optimizing scan parameters, such as frequency and amplitude, MRE could provide a good qualitative elastogram for targets with different elasticity values and dimensions. The second part investigated the feasibility of integrating MRE into radiation therapy (RT) workflow. With the aid of a tissue-equivalent prostate phantom (embedded with three dominant intraprostatic lesions (DILs)), an MRE-integrated RT framework was developed. This framework contains a comprehensive scan protocol including Computed Tomography (CT) scan, combined MRI/MRE scans and a Volumetric Modulated Arc Therapy (VMAT) technique for treatment delivery. The results showed that using the comprehensive information could boost the MRE defined DILs to 84 Gy while keeping the remainder of the prostate to 78 Gy. Using a VMAT based technique allowed us to achieve a highly conformal plan (conformity index for the prostate and combined DILs was 0.98 and 0.91). Based on our feasibility study, we concluded that MRE data can be used for targeted radiation dose escalation. In summary, this thesis demonstrates that MRE is feasible for applications in radiation oncology."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["MAGNETIC RESONANCE ELASTOGRAPHY FOR APPLICATIONS IN RADIATION THERAPY"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Venugopal, Niranjan","Babyn, Paul","Bui, Francis"],"dc:contributor.committeemember":["McWalter, Emily","Alexander, Andrew","Eramian, Mark"],"dc:creator":["Cui, Lumeng 1991-"],"dc:date.accessioned":["2017-09-13T16:17:03Z"],"dc:date.available":["2017-09-13T16:17:03Z"],"dc:date.created":["2017-10"],"dc:date.issued":["2017-09-13"],"dc:date.submitted":["October 2017"],"dc:date.updated":["2017-09-13T16:17:04Z"],"dc:description.abstract":["Magnetic resonance elastography (MRE) is an imaging technique that combines mechanical waves and magnetic resonance imaging (MRI) to determine the elastic properties of tissue. Because MRE is non-invasive, there is great potential and interest for its use in the detection of cancer. The first part of this thesis concentrates on parameter optimization and imaging quality of an MRE system. To do this, we developed a customized quality assurance phantom, and a series of quality control tests to characterize the MRE system. Our results demonstrated that through optimizing scan parameters, such as frequency and amplitude, MRE could provide a good qualitative elastogram for targets with different elasticity values and dimensions. The second part investigated the feasibility of integrating MRE into radiation therapy (RT) workflow. With the aid of a tissue-equivalent prostate phantom (embedded with three dominant intraprostatic lesions (DILs)), an MRE-integrated RT framework was developed. This framework contains a comprehensive scan protocol including Computed Tomography (CT) scan, combined MRI/MRE scans and a Volumetric Modulated Arc Therapy (VMAT) technique for treatment delivery. The results showed that using the comprehensive information could boost the MRE defined DILs to 84 Gy while keeping the remainder of the prostate to 78 Gy. Using a VMAT based technique allowed us to achieve a highly conformal plan (conformity index for the prostate and combined DILs was 0.98 and 0.91). Based on our feasibility study, we concluded that MRE data can be used for targeted radiation dose escalation. In summary, this thesis demonstrates that MRE is feasible for applications in radiation oncology."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/10388/8085"],"dc:subject":["MRE","MRI","Phantom","QA","Radiation Therapy"],"dc:title":["MAGNETIC RESONANCE ELASTOGRAPHY FOR APPLICATIONS IN RADIATION THERAPY"],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"thesis:degree_department":["Biomedical Engineering"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science (M.Sc.)"],"thesis:institution_name":["University of Saskatchewan"]},"updated_at":"2026-11-19T10:12:14Z"}