{"id":{"repo_id":"sask","oai_identifier":"oai:harvest.usask.ca:10388/8286"},"canonical_url":"https://search.ndltd.org/etd/sask/oai:harvest.usask.ca:10388/8286","repository":{"repo_id":"sask","name":"University of Saskatchewan","base_url":"https://harvest.usask.ca/server/oai/request"},"display":{"title":"Simulation of a 3-Fluid Membrane Liquid Desiccant Air-Conditioning System","abstract":"A liquid-to-air membrane energy exchanger (LAMEE) is able to simultaneously cool and dehumidify air by transferring heat and moisture between the air stream and a liquid desiccant solution. The heat and moisture transfer rates in a LAMEE can be enhanced if a third fluid stream is used to control the desiccant solution temperature in the LAMEE. A LAMEE with a third fluid stream is known as a 3-fluid LAMEE. Published studies on 3-fluid LAMEEs are limited to experiments on the exchanger under limited test conditions. This thesis focuses on simulating the performance of a 3-fluid LAMEE in a membrane liquid desiccant air-conditioning (M-LDAC) system. In the thesis, empirical correlations are developed based on experimental data to model the 3-fluid LAMEE and the limitations of the empirical model are evaluated. Subsequently, the 3-fluid and 2-fluid M-LDAC systems are simulated and compared at six different dehumidification load conditions. The simulation results show that, for most conditions, the 3-fluid M-LDAC system is able to meet the dehumidification load with a lower energy input than the 2-fluid M-LDAC system. The energy efficiency of the 2-fluid M-LDAC system is higher than the 3-fluid M-LDAC system at only the lowest dehumidification load. The 3-fluid and 2-fluid M-LDAC systems are paired with a radiant cooling system to condition a small office building located in a hot-humid climate (Miami, Florida). Both the 2-fluid and 3-fluid systems provide acceptable thermal environment within the office building but the energy consumption of the 2-fluid system is 50% higher than the 3-fluid system. This thesis concludes that the 3-fluid M-LDAC system may be more suitable than the 2-fluid M-LDAC system for hot and humid climates and in buildings with high dehumidification loads.","abstract_html":"A liquid-to-air membrane energy exchanger (LAMEE) is able to simultaneously cool and dehumidify air by transferring heat and moisture between the air stream and a liquid desiccant solution. The heat and moisture transfer rates in a LAMEE can be enhanced if a third fluid stream is used to control the desiccant solution temperature in the LAMEE. A LAMEE with a third fluid stream is known as a 3-fluid LAMEE. Published studies on 3-fluid LAMEEs are limited to experiments on the exchanger under limited test conditions. This thesis focuses on simulating the performance of a 3-fluid LAMEE in a membrane liquid desiccant air-conditioning (M-LDAC) system. In the thesis, empirical correlations are developed based on experimental data to model the 3-fluid LAMEE and the limitations of the empirical model are evaluated. Subsequently, the 3-fluid and 2-fluid M-LDAC systems are simulated and compared at six different dehumidification load conditions. The simulation results show that, for most conditions, the 3-fluid M-LDAC system is able to meet the dehumidification load with a lower energy input than the 2-fluid M-LDAC system. The energy efficiency of the 2-fluid M-LDAC system is higher than the 3-fluid M-LDAC system at only the lowest dehumidification load. The 3-fluid and 2-fluid M-LDAC systems are paired with a radiant cooling system to condition a small office building located in a hot-humid climate (Miami, Florida). Both the 2-fluid and 3-fluid systems provide acceptable thermal environment within the office building but the energy consumption of the 2-fluid system is 50% higher than the 3-fluid system. This thesis concludes that the 3-fluid M-LDAC system may be more suitable than the 2-fluid M-LDAC system for hot and humid climates and in buildings with high dehumidification loads.","abstract_has_math":false,"creators":["Storle, Devin 1991-"],"institution":"University of Saskatchewan","degree_name":"Master of Science (M.Sc.)","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Simonson, Carey"],"committee_chairs":[],"committee_members":["Torvi, David","Guo, Huiqing","Faried, Sherif O."],"year":2017,"date_issued":"2017-11-29","date_published":"2017-11-29","updated_at":"2026-11-19T10:13:05Z","subjects":["Liquid-to-ar membrane energy exchanger (LAMEE)","3-fluid LAMEE","Coefficient of Performance","TRNSYS","Liquid desiccant air-conditioning","air-conditioning"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10388/8286","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10388/8286","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://harvest.usask.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aharvest.usask.ca%3A10388%2F8286","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Simonson, Carey"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Torvi, David","Guo, Huiqing","Faried, Sherif O."]},{"key":"dc:creator","label":"Author","values":["Storle, Devin 1991-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-11-29T19:54:43Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-11-29T19:54:43Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2017-11"]},{"key":"dc:date.issued","label":"Date","values":["2017-11-29"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["November 2017"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2017-11-29T19:54:43Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_department","label":"Department","values":["Mechanical Engineering"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.Sc.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Saskatchewan"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Liquid-to-ar membrane energy exchanger (LAMEE)","3-fluid LAMEE","Coefficient of Performance","TRNSYS","Liquid desiccant air-conditioning","air-conditioning"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10388/8286"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A liquid-to-air membrane energy exchanger (LAMEE) is able to simultaneously cool and dehumidify air by transferring heat and moisture between the air stream and a liquid desiccant solution. The heat and moisture transfer rates in a LAMEE can be enhanced if a third fluid stream is used to control the desiccant solution temperature in the LAMEE. A LAMEE with a third fluid stream is known as a 3-fluid LAMEE. Published studies on 3-fluid LAMEEs are limited to experiments on the exchanger under limited test conditions. This thesis focuses on simulating the performance of a 3-fluid LAMEE in a membrane liquid desiccant air-conditioning (M-LDAC) system. In the thesis, empirical correlations are developed based on experimental data to model the 3-fluid LAMEE and the limitations of the empirical model are evaluated. Subsequently, the 3-fluid and 2-fluid M-LDAC systems are simulated and compared at six different dehumidification load conditions. The simulation results show that, for most conditions, the 3-fluid M-LDAC system is able to meet the dehumidification load with a lower energy input than the 2-fluid M-LDAC system. The energy efficiency of the 2-fluid M-LDAC system is higher than the 3-fluid M-LDAC system at only the lowest dehumidification load. The 3-fluid and 2-fluid M-LDAC systems are paired with a radiant cooling system to condition a small office building located in a hot-humid climate (Miami, Florida). Both the 2-fluid and 3-fluid systems provide acceptable thermal environment within the office building but the energy consumption of the 2-fluid system is 50% higher than the 3-fluid system. This thesis concludes that the 3-fluid M-LDAC system may be more suitable than the 2-fluid M-LDAC system for hot and humid climates and in buildings with high dehumidification loads."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Simulation of a 3-Fluid Membrane Liquid Desiccant Air-Conditioning System"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Simonson, Carey"],"dc:contributor.committeemember":["Torvi, David","Guo, Huiqing","Faried, Sherif O."],"dc:creator":["Storle, Devin 1991-"],"dc:date.accessioned":["2017-11-29T19:54:43Z"],"dc:date.available":["2017-11-29T19:54:43Z"],"dc:date.created":["2017-11"],"dc:date.issued":["2017-11-29"],"dc:date.submitted":["November 2017"],"dc:date.updated":["2017-11-29T19:54:43Z"],"dc:description.abstract":["A liquid-to-air membrane energy exchanger (LAMEE) is able to simultaneously cool and dehumidify air by transferring heat and moisture between the air stream and a liquid desiccant solution. The heat and moisture transfer rates in a LAMEE can be enhanced if a third fluid stream is used to control the desiccant solution temperature in the LAMEE. A LAMEE with a third fluid stream is known as a 3-fluid LAMEE. Published studies on 3-fluid LAMEEs are limited to experiments on the exchanger under limited test conditions. This thesis focuses on simulating the performance of a 3-fluid LAMEE in a membrane liquid desiccant air-conditioning (M-LDAC) system. In the thesis, empirical correlations are developed based on experimental data to model the 3-fluid LAMEE and the limitations of the empirical model are evaluated. Subsequently, the 3-fluid and 2-fluid M-LDAC systems are simulated and compared at six different dehumidification load conditions. The simulation results show that, for most conditions, the 3-fluid M-LDAC system is able to meet the dehumidification load with a lower energy input than the 2-fluid M-LDAC system. The energy efficiency of the 2-fluid M-LDAC system is higher than the 3-fluid M-LDAC system at only the lowest dehumidification load. The 3-fluid and 2-fluid M-LDAC systems are paired with a radiant cooling system to condition a small office building located in a hot-humid climate (Miami, Florida). Both the 2-fluid and 3-fluid systems provide acceptable thermal environment within the office building but the energy consumption of the 2-fluid system is 50% higher than the 3-fluid system. This thesis concludes that the 3-fluid M-LDAC system may be more suitable than the 2-fluid M-LDAC system for hot and humid climates and in buildings with high dehumidification loads."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/10388/8286"],"dc:subject":["Liquid-to-ar membrane energy exchanger (LAMEE)","3-fluid LAMEE","Coefficient of Performance","TRNSYS","Liquid desiccant air-conditioning","air-conditioning"],"dc:title":["Simulation of a 3-Fluid Membrane Liquid Desiccant Air-Conditioning System"],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"thesis:degree_department":["Mechanical Engineering"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science (M.Sc.)"],"thesis:institution_name":["University of Saskatchewan"]},"updated_at":"2026-11-19T10:13:05Z"}