{"id":{"repo_id":"sask","oai_identifier":"oai:harvest.usask.ca:10388/8344"},"canonical_url":"https://search.ndltd.org/etd/sask/oai:harvest.usask.ca:10388/8344","repository":{"repo_id":"sask","name":"University of Saskatchewan","base_url":"https://harvest.usask.ca/server/oai/request"},"display":{"title":"Calibration Methods for Head-Tracked 3D Displays","abstract":"Head-tracked 3D displays can provide a compelling 3D effect, but even small inaccuracies in the calibration of the participant’s viewpoint to the display can disrupt the 3D illusion. We propose a novel interactive procedure for a participant to easily and accurately calibrate a head-tracked display by visually aligning patterns across a multi-screen display. Head-tracker measurements are then calibrated to these known viewpoints. We conducted a user study to evaluate the effectiveness of different visual patterns and different display shapes. We found that the easiest to align shape was the spherical display and the best calibration pattern was the combination of circles and lines. We performed a quantitative camera-based calibration of a cubic display and found visual calibration outperformed manual tuning and generated viewpoint calibrations accurate to within a degree. Our work removes the usual, burdensome step of manual calibration when using head-tracked displays and paves the way for wider adoption of this inexpensive and effective 3D display technology.","abstract_html":"Head-tracked 3D displays can provide a compelling 3D effect, but even small inaccuracies in the calibration of the participant’s viewpoint to the display can disrupt the 3D illusion. We propose a novel interactive procedure for a participant to easily and accurately calibrate a head-tracked display by visually aligning patterns across a multi-screen display. Head-tracker measurements are then calibrated to these known viewpoints. We conducted a user study to evaluate the effectiveness of different visual patterns and different display shapes. We found that the easiest to align shape was the spherical display and the best calibration pattern was the combination of circles and lines. We performed a quantitative camera-based calibration of a cubic display and found visual calibration outperformed manual tuning and generated viewpoint calibrations accurate to within a degree. Our work removes the usual, burdensome step of manual calibration when using head-tracked displays and paves the way for wider adoption of this inexpensive and effective 3D display technology.","abstract_has_math":false,"creators":["Wagemakers, Andrew J 1993-"],"institution":"University of Saskatchewan","degree_name":"Master of Science (M.Sc.)","degree_level":"Masters","degree_discipline":"Computer Science","degree_department":"Computer Science","school":null,"contributors":[],"advisors":["Stavness, Ian"],"committee_chairs":[],"committee_members":["Gutwin, Carl","Mandryk, Regan","Maw, Sean"],"year":2018,"date_issued":"2018-01-15","date_published":"2018-01-15","updated_at":"2026-11-19T09:54:13Z","subjects":["Fish Tank VR","Calibration","Head Tracking","Visual Preception"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10388/8344","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10388/8344","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Asask%3Aoai%3Aharvest.usask.ca%3A10388%2F8344","prefix":"oai_dc"},"source_record":{"url":"https://harvest.usask.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aharvest.usask.ca%3A10388%2F8344","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Stavness, Ian"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Gutwin, Carl","Mandryk, Regan","Maw, Sean"]},{"key":"dc:creator","label":"Author","values":["Wagemakers, Andrew J 1993-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-01-15T17:58:05Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-01-15T17:58:05Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2018-04"]},{"key":"dc:date.issued","label":"Date","values":["2018-01-15"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["April 2018"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2018-01-15T17:58:05Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_department","label":"Department","values":["Computer Science"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Computer Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.Sc.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Saskatchewan"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Fish Tank VR","Calibration","Head Tracking","Visual Preception"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10388/8344"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Head-tracked 3D displays can provide a compelling 3D effect, but even small inaccuracies in the calibration of the participant’s viewpoint to the display can disrupt the 3D illusion. We propose a novel interactive procedure for a participant to easily and accurately calibrate a head-tracked display by visually aligning patterns across a multi-screen display. Head-tracker measurements are then calibrated to these known viewpoints. We conducted a user study to evaluate the effectiveness of different visual patterns and different display shapes. We found that the easiest to align shape was the spherical display and the best calibration pattern was the combination of circles and lines. We performed a quantitative camera-based calibration of a cubic display and found visual calibration outperformed manual tuning and generated viewpoint calibrations accurate to within a degree. Our work removes the usual, burdensome step of manual calibration when using head-tracked displays and paves the way for wider adoption of this inexpensive and effective 3D display technology."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Calibration Methods for Head-Tracked 3D Displays"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Stavness, Ian"],"dc:contributor.committeemember":["Gutwin, Carl","Mandryk, Regan","Maw, Sean"],"dc:creator":["Wagemakers, Andrew J 1993-"],"dc:date.accessioned":["2018-01-15T17:58:05Z"],"dc:date.available":["2018-01-15T17:58:05Z"],"dc:date.created":["2018-04"],"dc:date.issued":["2018-01-15"],"dc:date.submitted":["April 2018"],"dc:date.updated":["2018-01-15T17:58:05Z"],"dc:description.abstract":["Head-tracked 3D displays can provide a compelling 3D effect, but even small inaccuracies in the calibration of the participant’s viewpoint to the display can disrupt the 3D illusion. We propose a novel interactive procedure for a participant to easily and accurately calibrate a head-tracked display by visually aligning patterns across a multi-screen display. Head-tracker measurements are then calibrated to these known viewpoints. We conducted a user study to evaluate the effectiveness of different visual patterns and different display shapes. We found that the easiest to align shape was the spherical display and the best calibration pattern was the combination of circles and lines. We performed a quantitative camera-based calibration of a cubic display and found visual calibration outperformed manual tuning and generated viewpoint calibrations accurate to within a degree. Our work removes the usual, burdensome step of manual calibration when using head-tracked displays and paves the way for wider adoption of this inexpensive and effective 3D display technology."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/10388/8344"],"dc:subject":["Fish Tank VR","Calibration","Head Tracking","Visual Preception"],"dc:title":["Calibration Methods for Head-Tracked 3D Displays"],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"thesis:degree_department":["Computer Science"],"thesis:degree_discipline":["Computer Science"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science (M.Sc.)"],"thesis:institution_name":["University of Saskatchewan"]},"updated_at":"2026-11-19T09:54:13Z"}