{"id":{"repo_id":"sdstate","oai_identifier":"oai:openprairie.sdstate.edu:etd-2999"},"canonical_url":"https://search.ndltd.org/etd/sdstate/oai:openprairie.sdstate.edu:etd-2999","repository":{"repo_id":"sdstate","name":"South Dakota State University","base_url":"https://openprairie.sdstate.edu/do/oai/"},"display":{"title":"A CFD Template for Evaluating Aortic Aneurysm Repair Design","abstract":"This thesis created a template within CFD software to be able to import and quickly analyze new device designs for repair of aneurysms. This template can provide the vascular community with a streamlined, efficient testing method for prototyping and pre-clinical analysis of device performance. By using this template, device designers can undergo a multitude of design changes and iterations to tweak the properties of the device before undergoing a large-scale clinical trial that is required for FDA approval. The focus of this research was on stent-grafts for repair of abdominal aortic aneurysms (AAAs) and thoracic-abdominal aortic aneurysms (TAAAs). Using code written for the combination of multiple near-wall hemodynamic parameters, as well as a multitude of other flow parameters, five different geometries of potential stent-graft devices were analyzed. The outputs from the results of this study helped to determine computationally which devices provide optimal fluid mechanics throughout the vascular system. This research also provided insight on specific trends in device design that induce better flow to the bridging stents in order to help future development of devices. In general, shortcomings of devices with short bridging stents were well-documented in this study, coinciding with the recent removal of certain devices from commercial availability. Additionally, the stent-grafts with longer, gradually-sweeping bridging stents performed significantly better across a multitude of tests, including near-wall hemodynamics and general fluid mechanics. This goes against typical surgical procedure that calls for as short of bridging stents as possible. Using the data outputs from this study, potential locations of clotting and atherosclerosis formation can be predicted, and devices can be designed to minimize or eliminate those risks. These tests can be applied beyond AAAs and TAAAs, essentially anywhere within the vascular system. This shows the breadth of this template and how it can affect a multitude of areas within the biomedical community.","abstract_html":"This thesis created a template within CFD software to be able to import and quickly analyze new device designs for repair of aneurysms. This template can provide the vascular community with a streamlined, efficient testing method for prototyping and pre-clinical analysis of device performance. By using this template, device designers can undergo a multitude of design changes and iterations to tweak the properties of the device before undergoing a large-scale clinical trial that is required for FDA approval. The focus of this research was on stent-grafts for repair of abdominal aortic aneurysms (AAAs) and thoracic-abdominal aortic aneurysms (TAAAs). Using code written for the combination of multiple near-wall hemodynamic parameters, as well as a multitude of other flow parameters, five different geometries of potential stent-graft devices were analyzed. The outputs from the results of this study helped to determine computationally which devices provide optimal fluid mechanics throughout the vascular system. This research also provided insight on specific trends in device design that induce better flow to the bridging stents in order to help future development of devices. In general, shortcomings of devices with short bridging stents were well-documented in this study, coinciding with the recent removal of certain devices from commercial availability. Additionally, the stent-grafts with longer, gradually-sweeping bridging stents performed significantly better across a multitude of tests, including near-wall hemodynamics and general fluid mechanics. This goes against typical surgical procedure that calls for as short of bridging stents as possible. Using the data outputs from this study, potential locations of clotting and atherosclerosis formation can be predicted, and devices can be designed to minimize or eliminate those risks. These tests can be applied beyond AAAs and TAAAs, essentially anywhere within the vascular system. This shows the breadth of this template and how it can affect a multitude of areas within the biomedical community.","abstract_has_math":false,"creators":["Suess, Taylor Neal"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis - University Access Only","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Stephen Gent"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:58:21Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://openprairie.sdstate.edu/etd/1980","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://openprairie.sdstate.edu/etd/1980","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://openprairie.sdstate.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aopenprairie.sdstate.edu%3Aetd-2999","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Stephen Gent"]},{"key":"dc:creator","label":"Author","values":["Suess, Taylor Neal"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2017-11-08T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2015-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis - University Access Only"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://openprairie.sdstate.edu/etd/1980"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis created a template within CFD software to be able to import and quickly analyze new device designs for repair of aneurysms. This template can provide the vascular community with a streamlined, efficient testing method for prototyping and pre-clinical analysis of device performance. By using this template, device designers can undergo a multitude of design changes and iterations to tweak the properties of the device before undergoing a large-scale clinical trial that is required for FDA approval. The focus of this research was on stent-grafts for repair of abdominal aortic aneurysms (AAAs) and thoracic-abdominal aortic aneurysms (TAAAs). Using code written for the combination of multiple near-wall hemodynamic parameters, as well as a multitude of other flow parameters, five different geometries of potential stent-graft devices were analyzed. The outputs from the results of this study helped to determine computationally which devices provide optimal fluid mechanics throughout the vascular system. This research also provided insight on specific trends in device design that induce better flow to the bridging stents in order to help future development of devices. In general, shortcomings of devices with short bridging stents were well-documented in this study, coinciding with the recent removal of certain devices from commercial availability. Additionally, the stent-grafts with longer, gradually-sweeping bridging stents performed significantly better across a multitude of tests, including near-wall hemodynamics and general fluid mechanics. This goes against typical surgical procedure that calls for as short of bridging stents as possible. Using the data outputs from this study, potential locations of clotting and atherosclerosis formation can be predicted, and devices can be designed to minimize or eliminate those risks. These tests can be applied beyond AAAs and TAAAs, essentially anywhere within the vascular system. This shows the breadth of this template and how it can affect a multitude of areas within the biomedical community."]},{"key":"dc:title","label":"Title","values":["A CFD Template for Evaluating Aortic Aneurysm Repair Design"]}]}],"canonical_facts":{"dc:contributor":["Stephen Gent"],"dc:creator":["Suess, Taylor Neal"],"dc:date.available":["2017-11-08T08:00:00Z"],"dc:date.created":["2015-01-01T08:00:00Z"],"dc:description.abstract":["This thesis created a template within CFD software to be able to import and quickly analyze new device designs for repair of aneurysms. This template can provide the vascular community with a streamlined, efficient testing method for prototyping and pre-clinical analysis of device performance. By using this template, device designers can undergo a multitude of design changes and iterations to tweak the properties of the device before undergoing a large-scale clinical trial that is required for FDA approval. The focus of this research was on stent-grafts for repair of abdominal aortic aneurysms (AAAs) and thoracic-abdominal aortic aneurysms (TAAAs). Using code written for the combination of multiple near-wall hemodynamic parameters, as well as a multitude of other flow parameters, five different geometries of potential stent-graft devices were analyzed. The outputs from the results of this study helped to determine computationally which devices provide optimal fluid mechanics throughout the vascular system. This research also provided insight on specific trends in device design that induce better flow to the bridging stents in order to help future development of devices. In general, shortcomings of devices with short bridging stents were well-documented in this study, coinciding with the recent removal of certain devices from commercial availability. Additionally, the stent-grafts with longer, gradually-sweeping bridging stents performed significantly better across a multitude of tests, including near-wall hemodynamics and general fluid mechanics. This goes against typical surgical procedure that calls for as short of bridging stents as possible. Using the data outputs from this study, potential locations of clotting and atherosclerosis formation can be predicted, and devices can be designed to minimize or eliminate those risks. These tests can be applied beyond AAAs and TAAAs, essentially anywhere within the vascular system. This shows the breadth of this template and how it can affect a multitude of areas within the biomedical community."],"dc:identifier":["https://openprairie.sdstate.edu/etd/1980"],"dc:language":["en"],"dc:rights":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["A CFD Template for Evaluating Aortic Aneurysm Repair Design"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Thesis - University Access Only"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:58:21Z"}