{"id":{"repo_id":"sdstate","oai_identifier":"oai:openprairie.sdstate.edu:etd-3449"},"canonical_url":"https://search.ndltd.org/etd/sdstate/oai:openprairie.sdstate.edu:etd-3449","repository":{"repo_id":"sdstate","name":"South Dakota State University","base_url":"https://openprairie.sdstate.edu/do/oai/"},"display":{"title":"Optimization of Microfluidic Particle Separator Geometry Using Computational Fluid Dynamics","abstract":"Computational fluid dynamics software was used to simulate the motion of circulating tumor cells in a variety of microfluidic cell isolation devices. Design of several novel microfluidic cell isolation devices was aided by viewing streamlines of fluid in devices in simulation. Devices that performed best in simulation used 5-micrometer wide guiding channels to guide cells to the capture location in the device. While these devices performed better than other devices in simulation and captured all particles regardless of position along inlet, experimental results differ from simulation.","abstract_html":"Computational fluid dynamics software was used to simulate the motion of circulating tumor cells in a variety of microfluidic cell isolation devices. Design of several novel microfluidic cell isolation devices was aided by viewing streamlines of fluid in devices in simulation. Devices that performed best in simulation used 5-micrometer wide guiding channels to guide cells to the capture location in the device. While these devices performed better than other devices in simulation and captured all particles regardless of position along inlet, experimental results differ from simulation.","abstract_has_math":false,"creators":["Petersen, Joseph"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis - Open Access","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Jeffrey Doom"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:58:48Z","subjects":["circulating tumor cell","computational fluid dynamics","microfluidic","microtechnology","Dynamics and Dynamical Systems","Mechanical Engineering"],"languages":["en"],"rights":[],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://openprairie.sdstate.edu/etd/2419","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://openprairie.sdstate.edu/etd/2419","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://openprairie.sdstate.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aopenprairie.sdstate.edu%3Aetd-3449","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Jeffrey Doom"]},{"key":"dc:creator","label":"Author","values":["Petersen, Joseph"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2018-05-07T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2018-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis - Open Access"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["circulating tumor cell","computational fluid dynamics","microfluidic","microtechnology","Dynamics and Dynamical Systems","Mechanical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://openprairie.sdstate.edu/etd/2419"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Computational fluid dynamics software was used to simulate the motion of circulating tumor cells in a variety of microfluidic cell isolation devices. Design of several novel microfluidic cell isolation devices was aided by viewing streamlines of fluid in devices in simulation. Devices that performed best in simulation used 5-micrometer wide guiding channels to guide cells to the capture location in the device. While these devices performed better than other devices in simulation and captured all particles regardless of position along inlet, experimental results differ from simulation."]},{"key":"dc:title","label":"Title","values":["Optimization of Microfluidic Particle Separator Geometry Using Computational Fluid Dynamics"]}]}],"canonical_facts":{"dc:contributor":["Jeffrey Doom"],"dc:creator":["Petersen, Joseph"],"dc:date.available":["2018-05-07T07:00:00Z"],"dc:date.created":["2018-01-01T08:00:00Z"],"dc:description.abstract":["Computational fluid dynamics software was used to simulate the motion of circulating tumor cells in a variety of microfluidic cell isolation devices. Design of several novel microfluidic cell isolation devices was aided by viewing streamlines of fluid in devices in simulation. Devices that performed best in simulation used 5-micrometer wide guiding channels to guide cells to the capture location in the device. While these devices performed better than other devices in simulation and captured all particles regardless of position along inlet, experimental results differ from simulation."],"dc:identifier":["https://openprairie.sdstate.edu/etd/2419"],"dc:language":["en"],"dc:rights":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["circulating tumor cell","computational fluid dynamics","microfluidic","microtechnology","Dynamics and Dynamical Systems","Mechanical Engineering"],"dc:title":["Optimization of Microfluidic Particle Separator Geometry Using Computational Fluid Dynamics"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Thesis - Open Access"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:58:48Z"}