{"id":{"repo_id":"sdstate","oai_identifier":"oai:openprairie.sdstate.edu:etd-3495"},"canonical_url":"https://search.ndltd.org/etd/sdstate/oai:openprairie.sdstate.edu:etd-3495","repository":{"repo_id":"sdstate","name":"South Dakota State University","base_url":"https://openprairie.sdstate.edu/do/oai/"},"display":{"title":"Development of a High Performance Liquid Chromatography Method for the Analysis of Next-generation Cyanide Antidote, 3-mercaptopyruvate, in Plasma","abstract":"Although the current FDA approved cyanide antidotes (i.e., sodium nitrite, sodium thiosulfate, and hydoxocoboalamine) are effective for treating cyanide poisoning, each individual antidote has major limitations, including large effective dosage, delayed onset of action, or dependence on enzymes generally confined to specific organs. To overcome these current limitations, next-generation cyanide antidotes are being investigated, including 3-mercaptopyruvate (3-MP). Analytical methods capable of detecting 3-MP from plasma are essential for the development of 3-MP as a nextgeneration cyanide antidote. Although 3-MP has been analyzed by LC-MS-MS, this instrument is not widely available. Therefore, a high performance liquid chromatography (HPLC) method with fluorescence detection (FLD) was developed to analyze 3-MP from swine plasma such that more labs could potentially perform the method. Sample preparation included spiking the plasma with the internal standard (3-mercaptopropionic acid) and reacting the 3-MP and IS with monobromobimane to prevent the characteristic dimerization of 3-MP. The method produced a limit of detection of 0.5 nM, a large dynamic range, and good accuracy and precision. The solid phase mixed-mode anion exchange sample preparation protocol produced excellent selectivity for the method. The wide availability and affordability of the instrumentation and the simple of the implementation method presented should allow more labs to contribute to further investigations of 3-MP as a promising cyanide antidote.","abstract_html":"Although the current FDA approved cyanide antidotes (i.e., sodium nitrite, sodium thiosulfate, and hydoxocoboalamine) are effective for treating cyanide poisoning, each individual antidote has major limitations, including large effective dosage, delayed onset of action, or dependence on enzymes generally confined to specific organs. To overcome these current limitations, next-generation cyanide antidotes are being investigated, including 3-mercaptopyruvate (3-MP). Analytical methods capable of detecting 3-MP from plasma are essential for the development of 3-MP as a nextgeneration cyanide antidote. Although 3-MP has been analyzed by LC-MS-MS, this instrument is not widely available. Therefore, a high performance liquid chromatography (HPLC) method with fluorescence detection (FLD) was developed to analyze 3-MP from swine plasma such that more labs could potentially perform the method. Sample preparation included spiking the plasma with the internal standard (3-mercaptopropionic acid) and reacting the 3-MP and IS with monobromobimane to prevent the characteristic dimerization of 3-MP. The method produced a limit of detection of 0.5 nM, a large dynamic range, and good accuracy and precision. The solid phase mixed-mode anion exchange sample preparation protocol produced excellent selectivity for the method. The wide availability and affordability of the instrumentation and the simple of the implementation method presented should allow more labs to contribute to further investigations of 3-MP as a promising cyanide antidote.","abstract_has_math":false,"creators":["Alzhrani, Elaf"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis - Open Access","degree_discipline":"Chemistry and Biochemistry","degree_department":null,"school":null,"contributors":["Brian Logue"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:58:58Z","subjects":["3-Mercaptopyruvate","cyanide","cyanide antidotes","fluorescence","HPLC","Analytical Chemistry"],"languages":["en"],"rights":[],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://openprairie.sdstate.edu/etd/2457","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://openprairie.sdstate.edu/etd/2457","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://openprairie.sdstate.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aopenprairie.sdstate.edu%3Aetd-3495","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Brian Logue"]},{"key":"dc:creator","label":"Author","values":["Alzhrani, Elaf"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2018-05-16T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2018-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry and Biochemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis - Open Access"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["3-Mercaptopyruvate","cyanide","cyanide antidotes","fluorescence","HPLC","Analytical Chemistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://openprairie.sdstate.edu/etd/2457"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Although the current FDA approved cyanide antidotes (i.e., sodium nitrite, sodium thiosulfate, and hydoxocoboalamine) are effective for treating cyanide poisoning, each individual antidote has major limitations, including large effective dosage, delayed onset of action, or dependence on enzymes generally confined to specific organs. To overcome these current limitations, next-generation cyanide antidotes are being investigated, including 3-mercaptopyruvate (3-MP). Analytical methods capable of detecting 3-MP from plasma are essential for the development of 3-MP as a nextgeneration cyanide antidote. Although 3-MP has been analyzed by LC-MS-MS, this instrument is not widely available. Therefore, a high performance liquid chromatography (HPLC) method with fluorescence detection (FLD) was developed to analyze 3-MP from swine plasma such that more labs could potentially perform the method. Sample preparation included spiking the plasma with the internal standard (3-mercaptopropionic acid) and reacting the 3-MP and IS with monobromobimane to prevent the characteristic dimerization of 3-MP. The method produced a limit of detection of 0.5 nM, a large dynamic range, and good accuracy and precision. The solid phase mixed-mode anion exchange sample preparation protocol produced excellent selectivity for the method. The wide availability and affordability of the instrumentation and the simple of the implementation method presented should allow more labs to contribute to further investigations of 3-MP as a promising cyanide antidote."]},{"key":"dc:title","label":"Title","values":["Development of a High Performance Liquid Chromatography Method for the Analysis of Next-generation Cyanide Antidote, 3-mercaptopyruvate, in Plasma"]}]}],"canonical_facts":{"dc:contributor":["Brian Logue"],"dc:creator":["Alzhrani, Elaf"],"dc:date.available":["2018-05-16T07:00:00Z"],"dc:date.created":["2018-01-01T08:00:00Z"],"dc:description.abstract":["Although the current FDA approved cyanide antidotes (i.e., sodium nitrite, sodium thiosulfate, and hydoxocoboalamine) are effective for treating cyanide poisoning, each individual antidote has major limitations, including large effective dosage, delayed onset of action, or dependence on enzymes generally confined to specific organs. To overcome these current limitations, next-generation cyanide antidotes are being investigated, including 3-mercaptopyruvate (3-MP). Analytical methods capable of detecting 3-MP from plasma are essential for the development of 3-MP as a nextgeneration cyanide antidote. Although 3-MP has been analyzed by LC-MS-MS, this instrument is not widely available. Therefore, a high performance liquid chromatography (HPLC) method with fluorescence detection (FLD) was developed to analyze 3-MP from swine plasma such that more labs could potentially perform the method. Sample preparation included spiking the plasma with the internal standard (3-mercaptopropionic acid) and reacting the 3-MP and IS with monobromobimane to prevent the characteristic dimerization of 3-MP. The method produced a limit of detection of 0.5 nM, a large dynamic range, and good accuracy and precision. The solid phase mixed-mode anion exchange sample preparation protocol produced excellent selectivity for the method. The wide availability and affordability of the instrumentation and the simple of the implementation method presented should allow more labs to contribute to further investigations of 3-MP as a promising cyanide antidote."],"dc:identifier":["https://openprairie.sdstate.edu/etd/2457"],"dc:language":["en"],"dc:rights":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["3-Mercaptopyruvate","cyanide","cyanide antidotes","fluorescence","HPLC","Analytical Chemistry"],"dc:title":["Development of a High Performance Liquid Chromatography Method for the Analysis of Next-generation Cyanide Antidote, 3-mercaptopyruvate, in Plasma"],"thesis:degree_discipline":["Chemistry and Biochemistry"],"thesis:degree_level":["Thesis - Open Access"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:58:58Z"}