{"id":{"repo_id":"sdstate","oai_identifier":"oai:openprairie.sdstate.edu:etd-3532"},"canonical_url":"https://search.ndltd.org/etd/sdstate/oai:openprairie.sdstate.edu:etd-3532","repository":{"repo_id":"sdstate","name":"South Dakota State University","base_url":"https://openprairie.sdstate.edu/do/oai/"},"display":{"title":"Construction and Evaluation of the Performance of a Horizontal Well in a Shallow, Thin Aquifer","abstract":"Since infiltration galleries have been effective as a means of securing large quantities of water from thin aquifers, the question has arisen as to whether or not a small horizontal well that would yield sufficient water for irrigation could be constructed at a cost that would be within the budget of the family-sized farm in South Dakota. If so, a subsequent problem would be the development of some method of estimating the quantity of water a particular aquifer will yield to such a well. A possible approach would be to relate a certain length of horizontal casing to a vertical well of some particular diameter. If such a relationship can be found, the performance of such a well in another place could be predicted from data collected during a conventional pump test. This study will be confined to the details of the dragline construction of a pit, the placement of a horizontal well in a shallow thin aquifer; a, and an actual pump test to learn if a certain length of horizontal casing may be equivalent to a vertical well of some particular radius.","abstract_html":"Since infiltration galleries have been effective as a means of securing large quantities of water from thin aquifers, the question has arisen as to whether or not a small horizontal well that would yield sufficient water for irrigation could be constructed at a cost that would be within the budget of the family-sized farm in South Dakota. If so, a subsequent problem would be the development of some method of estimating the quantity of water a particular aquifer will yield to such a well. A possible approach would be to relate a certain length of horizontal casing to a vertical well of some particular diameter. If such a relationship can be found, the performance of such a well in another place could be predicted from data collected during a conventional pump test. This study will be confined to the details of the dragline construction of a pit, the placement of a horizontal well in a shallow thin aquifer; a, and an actual pump test to learn if a certain length of horizontal casing may be equivalent to a vertical well of some particular radius.","abstract_has_math":false,"creators":["Doering, Eugene J."],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis - Open Access","degree_discipline":"Agricultural Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:58:58Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://openprairie.sdstate.edu/etd/2501","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://openprairie.sdstate.edu/etd/2501","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://openprairie.sdstate.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aopenprairie.sdstate.edu%3Aetd-3532","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Doering, Eugene J."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1958-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Agricultural Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis - Open Access"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://openprairie.sdstate.edu/etd/2501"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Since infiltration galleries have been effective as a means of securing large quantities of water from thin aquifers, the question has arisen as to whether or not a small horizontal well that would yield sufficient water for irrigation could be constructed at a cost that would be within the budget of the family-sized farm in South Dakota. If so, a subsequent problem would be the development of some method of estimating the quantity of water a particular aquifer will yield to such a well. A possible approach would be to relate a certain length of horizontal casing to a vertical well of some particular diameter. If such a relationship can be found, the performance of such a well in another place could be predicted from data collected during a conventional pump test. This study will be confined to the details of the dragline construction of a pit, the placement of a horizontal well in a shallow thin aquifer; a, and an actual pump test to learn if a certain length of horizontal casing may be equivalent to a vertical well of some particular radius."]},{"key":"dc:title","label":"Title","values":["Construction and Evaluation of the Performance of a Horizontal Well in a Shallow, Thin Aquifer"]}]}],"canonical_facts":{"dc:creator":["Doering, Eugene J."],"dc:date.created":["1958-01-01T08:00:00Z"],"dc:description.abstract":["Since infiltration galleries have been effective as a means of securing large quantities of water from thin aquifers, the question has arisen as to whether or not a small horizontal well that would yield sufficient water for irrigation could be constructed at a cost that would be within the budget of the family-sized farm in South Dakota. If so, a subsequent problem would be the development of some method of estimating the quantity of water a particular aquifer will yield to such a well. A possible approach would be to relate a certain length of horizontal casing to a vertical well of some particular diameter. If such a relationship can be found, the performance of such a well in another place could be predicted from data collected during a conventional pump test. This study will be confined to the details of the dragline construction of a pit, the placement of a horizontal well in a shallow thin aquifer; a, and an actual pump test to learn if a certain length of horizontal casing may be equivalent to a vertical well of some particular radius."],"dc:identifier":["https://openprairie.sdstate.edu/etd/2501"],"dc:language":["en"],"dc:title":["Construction and Evaluation of the Performance of a Horizontal Well in a Shallow, Thin Aquifer"],"thesis:degree_discipline":["Agricultural Engineering"],"thesis:degree_level":["Thesis - Open Access"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T08:58:58Z"}