{"id":{"repo_id":"sdstate","oai_identifier":"oai:openprairie.sdstate.edu:etd-5065"},"canonical_url":"https://search.ndltd.org/etd/sdstate/oai:openprairie.sdstate.edu:etd-5065","repository":{"repo_id":"sdstate","name":"South Dakota State University","base_url":"https://openprairie.sdstate.edu/do/oai/"},"display":{"title":"Two-Dimensional Nanomaterials and Their Composites for Electrochemical Detection of Toxic Mercury Ions in Water","abstract":"The presence of trace amounts of mercury ion (Hg2+) in drinking water has a detrimental effect on human health. The development of an electrochemical sensor for Hg2+ detection is still challenging to obtain ultra-trace sensitivity, excellent selectivity, wide Linear Detection Ranges (LDRs), and ultra-low detection limit. This work presents an electrochemical sensor based on two-dimensional nanomaterials and their composites for the enhanced sensing of Hg2+ in water. Graphene oxide (GO)-silver nanowires (AgNWs) composite and metallic 1T phase tungsten disulfide (WS2) microflowers were utilized for the fabrication of electrochemical sensors using drop-casting. Under the optimized experimental conditions, the GO-AgNWs composite modified sensor showed a high sensitivity of ~ 0.29 μA/nM and linear response in the range of 1-70 nM toward Hg2+, whereas 1T-WS2 microflowers modified sensor showed excellent sensitivities of ~ 15.9 μA/μM, 2.54 μA/μM, 13.84 μA/μM, and 0.04646 μA/μM toward Hg2+ with LDRs of 1- 90 nM, 0.1-0.4 μM, 0.5-1.0 μM, and 0.1-1.0 mM, respectively. An ultra-low detection limit of 0.1 nM and 0.0798 nM or 79.8 pM toward Hg2+ was obtained by GO-AgNWs composite and 1T-WS2 modified sensors, which are well below the guideline value recommended by the World Health Organization and the United States Environmental Protection Agency. The sensors exhibited excellent selectivity for Hg2+ against other heavy metal ions including Cu2+, Fe3+, Ni2+, Pb2+, Cr3+, K+, Na+, Ag+, Sn2+, and Cd2+. The thus obtained excellent sensitivity and selectivity with wide LDRs and ultra-low detection limits can be attributed to the synergistic effect of GO and conductive AgNWs, high conductivity, large surface area microflower structured 1T-WS2, and the complexation of Hg2+ ions with sulfur (S2-) and GO. In addition to good repeatability, reproducibility, and stability, these sensors showed practical feasibility of Hg2+ detection in tap water suggesting a promising device for real applications.","abstract_html":"The presence of trace amounts of mercury ion (Hg2+) in drinking water has a detrimental effect on human health. The development of an electrochemical sensor for Hg2+ detection is still challenging to obtain ultra-trace sensitivity, excellent selectivity, wide Linear Detection Ranges (LDRs), and ultra-low detection limit. This work presents an electrochemical sensor based on two-dimensional nanomaterials and their composites for the enhanced sensing of Hg2+ in water. Graphene oxide (GO)-silver nanowires (AgNWs) composite and metallic 1T phase tungsten disulfide (WS2) microflowers were utilized for the fabrication of electrochemical sensors using drop-casting. Under the optimized experimental conditions, the GO-AgNWs composite modified sensor showed a high sensitivity of ~ 0.29 μA/nM and linear response in the range of 1-70 nM toward Hg2+, whereas 1T-WS2 microflowers modified sensor showed excellent sensitivities of ~ 15.9 μA/μM, 2.54 μA/μM, 13.84 μA/μM, and 0.04646 μA/μM toward Hg2+ with LDRs of 1- 90 nM, 0.1-0.4 μM, 0.5-1.0 μM, and 0.1-1.0 mM, respectively. An ultra-low detection limit of 0.1 nM and 0.0798 nM or 79.8 pM toward Hg2+ was obtained by GO-AgNWs composite and 1T-WS2 modified sensors, which are well below the guideline value recommended by the World Health Organization and the United States Environmental Protection Agency. The sensors exhibited excellent selectivity for Hg2+ against other heavy metal ions including Cu2+, Fe3+, Ni2+, Pb2+, Cr3+, K+, Na+, Ag+, Sn2+, and Cd2+. The thus obtained excellent sensitivity and selectivity with wide LDRs and ultra-low detection limits can be attributed to the synergistic effect of GO and conductive AgNWs, high conductivity, large surface area microflower structured 1T-WS2, and the complexation of Hg2+ ions with sulfur (S2-) and GO. In addition to good repeatability, reproducibility, and stability, these sensors showed practical feasibility of Hg2+ detection in tap water suggesting a promising device for real applications.","abstract_has_math":false,"creators":["Rahman, Md Tawabur"],"institution":null,"degree_name":"Doctor of Philosophy (PhD)","degree_level":"Dissertation - Open Access","degree_discipline":"Electrical Engineering and Computer Science","degree_department":null,"school":null,"contributors":["Qiquan Qiao"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:00:43Z","subjects":["Electrochemical","Graphene oxide","Mercury","microflowers","silver nanowires","WS2","Chemical Engineering","Electrical and Computer Engineering","Materials Science and Engineering"],"languages":[],"rights":[],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://openprairie.sdstate.edu/etd/4020","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://openprairie.sdstate.edu/etd/4020","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://openprairie.sdstate.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aopenprairie.sdstate.edu%3Aetd-5065","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Qiquan Qiao"]},{"key":"dc:creator","label":"Author","values":["Rahman, Md Tawabur"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2021-03-15T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2020-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering and Computer Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation - Open Access"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (PhD)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrochemical","Graphene oxide","Mercury","microflowers","silver nanowires","WS2","Chemical Engineering","Electrical and Computer Engineering","Materials Science and Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://openprairie.sdstate.edu/etd/4020"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The presence of trace amounts of mercury ion (Hg2+) in drinking water has a detrimental effect on human health. The development of an electrochemical sensor for Hg2+ detection is still challenging to obtain ultra-trace sensitivity, excellent selectivity, wide Linear Detection Ranges (LDRs), and ultra-low detection limit. This work presents an electrochemical sensor based on two-dimensional nanomaterials and their composites for the enhanced sensing of Hg2+ in water. Graphene oxide (GO)-silver nanowires (AgNWs) composite and metallic 1T phase tungsten disulfide (WS2) microflowers were utilized for the fabrication of electrochemical sensors using drop-casting. Under the optimized experimental conditions, the GO-AgNWs composite modified sensor showed a high sensitivity of ~ 0.29 μA/nM and linear response in the range of 1-70 nM toward Hg2+, whereas 1T-WS2 microflowers modified sensor showed excellent sensitivities of ~ 15.9 μA/μM, 2.54 μA/μM, 13.84 μA/μM, and 0.04646 μA/μM toward Hg2+ with LDRs of 1- 90 nM, 0.1-0.4 μM, 0.5-1.0 μM, and 0.1-1.0 mM, respectively. An ultra-low detection limit of 0.1 nM and 0.0798 nM or 79.8 pM toward Hg2+ was obtained by GO-AgNWs composite and 1T-WS2 modified sensors, which are well below the guideline value recommended by the World Health Organization and the United States Environmental Protection Agency. The sensors exhibited excellent selectivity for Hg2+ against other heavy metal ions including Cu2+, Fe3+, Ni2+, Pb2+, Cr3+, K+, Na+, Ag+, Sn2+, and Cd2+. The thus obtained excellent sensitivity and selectivity with wide LDRs and ultra-low detection limits can be attributed to the synergistic effect of GO and conductive AgNWs, high conductivity, large surface area microflower structured 1T-WS2, and the complexation of Hg2+ ions with sulfur (S2-) and GO. In addition to good repeatability, reproducibility, and stability, these sensors showed practical feasibility of Hg2+ detection in tap water suggesting a promising device for real applications."]},{"key":"dc:title","label":"Title","values":["Two-Dimensional Nanomaterials and Their Composites for Electrochemical Detection of Toxic Mercury Ions in Water"]}]}],"canonical_facts":{"dc:contributor":["Qiquan Qiao"],"dc:creator":["Rahman, Md Tawabur"],"dc:date.available":["2021-03-15T07:00:00Z"],"dc:date.created":["2020-01-01T08:00:00Z"],"dc:description.abstract":["The presence of trace amounts of mercury ion (Hg2+) in drinking water has a detrimental effect on human health. The development of an electrochemical sensor for Hg2+ detection is still challenging to obtain ultra-trace sensitivity, excellent selectivity, wide Linear Detection Ranges (LDRs), and ultra-low detection limit. This work presents an electrochemical sensor based on two-dimensional nanomaterials and their composites for the enhanced sensing of Hg2+ in water. Graphene oxide (GO)-silver nanowires (AgNWs) composite and metallic 1T phase tungsten disulfide (WS2) microflowers were utilized for the fabrication of electrochemical sensors using drop-casting. Under the optimized experimental conditions, the GO-AgNWs composite modified sensor showed a high sensitivity of ~ 0.29 μA/nM and linear response in the range of 1-70 nM toward Hg2+, whereas 1T-WS2 microflowers modified sensor showed excellent sensitivities of ~ 15.9 μA/μM, 2.54 μA/μM, 13.84 μA/μM, and 0.04646 μA/μM toward Hg2+ with LDRs of 1- 90 nM, 0.1-0.4 μM, 0.5-1.0 μM, and 0.1-1.0 mM, respectively. An ultra-low detection limit of 0.1 nM and 0.0798 nM or 79.8 pM toward Hg2+ was obtained by GO-AgNWs composite and 1T-WS2 modified sensors, which are well below the guideline value recommended by the World Health Organization and the United States Environmental Protection Agency. The sensors exhibited excellent selectivity for Hg2+ against other heavy metal ions including Cu2+, Fe3+, Ni2+, Pb2+, Cr3+, K+, Na+, Ag+, Sn2+, and Cd2+. The thus obtained excellent sensitivity and selectivity with wide LDRs and ultra-low detection limits can be attributed to the synergistic effect of GO and conductive AgNWs, high conductivity, large surface area microflower structured 1T-WS2, and the complexation of Hg2+ ions with sulfur (S2-) and GO. In addition to good repeatability, reproducibility, and stability, these sensors showed practical feasibility of Hg2+ detection in tap water suggesting a promising device for real applications."],"dc:identifier":["https://openprairie.sdstate.edu/etd/4020"],"dc:rights":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Electrochemical","Graphene oxide","Mercury","microflowers","silver nanowires","WS2","Chemical Engineering","Electrical and Computer Engineering","Materials Science and Engineering"],"dc:title":["Two-Dimensional Nanomaterials and Their Composites for Electrochemical Detection of Toxic Mercury Ions in Water"],"thesis:degree_discipline":["Electrical Engineering and Computer Science"],"thesis:degree_level":["Dissertation - Open Access"],"thesis:degree_name":["Doctor of Philosophy (PhD)"]},"updated_at":"2026-11-19T09:00:43Z"}