{"id":{"repo_id":"sdstate","oai_identifier":"oai:openprairie.sdstate.edu:etd-5607"},"canonical_url":"https://search.ndltd.org/etd/sdstate/oai:openprairie.sdstate.edu:etd-5607","repository":{"repo_id":"sdstate","name":"South Dakota State University","base_url":"https://openprairie.sdstate.edu/do/oai/"},"display":{"title":"Comparison of Earth Loop Systems for Livestock Housing","abstract":"A parametric analysis was made on open and closed earth loop systems using the Kelvin line-source theory. The analyses included varying the pipe diameter, pipe type, pipe depth, fluid velocity, soil thermal conductivity, and fluid type (for closed systems). The open loop system uses substantially shorter pipe lengths and produces smaller heat loads than the closed system. With modifications to the line-source theory, an analysis was made on a swine facility requiring 8790 W of supplemental heat. The open-loop system would require 80 W to move the air through 400 m of pipe with an inlet temperature of -29°C. The closed-loop system would require 148 W to move the calcium chloride through 1653 m of pipe with an inlet temperature of -5°C. Making a comparison based on an equivalent inlet temperature of soc, the open-loop system would require 58 W to move the air through 275 m of pipe; but the system would produce only 2850 W of supplemental heat.","abstract_html":"A parametric analysis was made on open and closed earth loop systems using the Kelvin line-source theory. The analyses included varying the pipe diameter, pipe type, pipe depth, fluid velocity, soil thermal conductivity, and fluid type (for closed systems). The open loop system uses substantially shorter pipe lengths and produces smaller heat loads than the closed system. With modifications to the line-source theory, an analysis was made on a swine facility requiring 8790 W of supplemental heat. The open-loop system would require 80 W to move the air through 400 m of pipe with an inlet temperature of -29°C. The closed-loop system would require 148 W to move the calcium chloride through 1653 m of pipe with an inlet temperature of -5°C. Making a comparison based on an equivalent inlet temperature of soc, the open-loop system would require 58 W to move the air through 275 m of pipe; but the system would produce only 2850 W of supplemental heat.","abstract_has_math":false,"creators":["Glawe, Barbara J."],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis - University Access Only","degree_discipline":"Agricultural Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:01:18Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://openprairie.sdstate.edu/etd/4573","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://openprairie.sdstate.edu/etd/4573","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://openprairie.sdstate.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aopenprairie.sdstate.edu%3Aetd-5607","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Glawe, Barbara J."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2020-09-22T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["1989-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Agricultural Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis - University Access Only"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://openprairie.sdstate.edu/etd/4573"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A parametric analysis was made on open and closed earth loop systems using the Kelvin line-source theory. The analyses included varying the pipe diameter, pipe type, pipe depth, fluid velocity, soil thermal conductivity, and fluid type (for closed systems). The open loop system uses substantially shorter pipe lengths and produces smaller heat loads than the closed system. With modifications to the line-source theory, an analysis was made on a swine facility requiring 8790 W of supplemental heat. The open-loop system would require 80 W to move the air through 400 m of pipe with an inlet temperature of -29°C. The closed-loop system would require 148 W to move the calcium chloride through 1653 m of pipe with an inlet temperature of -5°C. Making a comparison based on an equivalent inlet temperature of soc, the open-loop system would require 58 W to move the air through 275 m of pipe; but the system would produce only 2850 W of supplemental heat."]},{"key":"dc:title","label":"Title","values":["Comparison of Earth Loop Systems for Livestock Housing"]}]}],"canonical_facts":{"dc:creator":["Glawe, Barbara J."],"dc:date.available":["2020-09-22T07:00:00Z"],"dc:date.created":["1989-01-01T08:00:00Z"],"dc:description.abstract":["A parametric analysis was made on open and closed earth loop systems using the Kelvin line-source theory. The analyses included varying the pipe diameter, pipe type, pipe depth, fluid velocity, soil thermal conductivity, and fluid type (for closed systems). The open loop system uses substantially shorter pipe lengths and produces smaller heat loads than the closed system. With modifications to the line-source theory, an analysis was made on a swine facility requiring 8790 W of supplemental heat. The open-loop system would require 80 W to move the air through 400 m of pipe with an inlet temperature of -29°C. The closed-loop system would require 148 W to move the calcium chloride through 1653 m of pipe with an inlet temperature of -5°C. Making a comparison based on an equivalent inlet temperature of soc, the open-loop system would require 58 W to move the air through 275 m of pipe; but the system would produce only 2850 W of supplemental heat."],"dc:identifier":["https://openprairie.sdstate.edu/etd/4573"],"dc:title":["Comparison of Earth Loop Systems for Livestock Housing"],"thesis:degree_discipline":["Agricultural Engineering"],"thesis:degree_level":["Thesis - University Access Only"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T09:01:18Z"}