{"id":{"repo_id":"sdstate","oai_identifier":"oai:openprairie.sdstate.edu:etd-6327"},"canonical_url":"https://search.ndltd.org/etd/sdstate/oai:openprairie.sdstate.edu:etd-6327","repository":{"repo_id":"sdstate","name":"South Dakota State University","base_url":"https://openprairie.sdstate.edu/do/oai/"},"display":{"title":"Ozone Pilot Plant Studies of Six Municipal Water Supplies","abstract":"Six ozone pilot plant water quality studies were performed on water supplies of five Eastern South Dakota Cities and one Southern Minnesota City. The water supplies for these cities included groundwater at Brookings and Sioux Falls, South Dakota, river water at Huron and Yankton, South Dakota, and lake water at Watertown, South Dakota and Fairmont, Minnesota. The six study sites were investigated by researchers at South Dakota State University, Brookings, South Dakota, and the results are reviewed in this paper. The objective of the studies was to determine optimum ozone dosages and contact times for reducing odors, chlorine demand, organic carbon, trihalomethanes, iron, and manganese. Tests were also done to assess flocculation effects on those plants that depended on settling. The results were utilized to establish capital and operating costs. Test parameters used in the studies included: ozone dosage and contact time, pH, turbidity, odor, temperature, chlorine, absorbance, color, iron, manganese, chemical oxygen demand (COD), and total organic carbon (TOC). The results of ozonation on the varying water supplies were found to be highly dose dependent. Ozonation generally reduced odors, chlorine demand, TOC, trihalomethane formation, and COD levels. Ozonation oxidized iron and manganese, creating fine particle precipitates. The cost of ozonation varied from 6.7 to 33.4 cents per 1,000 gallons of water treated.","abstract_html":"Six ozone pilot plant water quality studies were performed on water supplies of five Eastern South Dakota Cities and one Southern Minnesota City. The water supplies for these cities included groundwater at Brookings and Sioux Falls, South Dakota, river water at Huron and Yankton, South Dakota, and lake water at Watertown, South Dakota and Fairmont, Minnesota. The six study sites were investigated by researchers at South Dakota State University, Brookings, South Dakota, and the results are reviewed in this paper. The objective of the studies was to determine optimum ozone dosages and contact times for reducing odors, chlorine demand, organic carbon, trihalomethanes, iron, and manganese. Tests were also done to assess flocculation effects on those plants that depended on settling. The results were utilized to establish capital and operating costs. Test parameters used in the studies included: ozone dosage and contact time, pH, turbidity, odor, temperature, chlorine, absorbance, color, iron, manganese, chemical oxygen demand (COD), and total organic carbon (TOC). The results of ozonation on the varying water supplies were found to be highly dose dependent. Ozonation generally reduced odors, chlorine demand, TOC, trihalomethane formation, and COD levels. Ozonation oxidized iron and manganese, creating fine particle precipitates. The cost of ozonation varied from 6.7 to 33.4 cents per 1,000 gallons of water treated.","abstract_has_math":false,"creators":["Bjerke, Bradley S."],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis - University Access Only","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":["Dwayne A. Rollag"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:02:16Z","subjects":["Civil Engineering","Engineering"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://openprairie.sdstate.edu/etd/5316","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://openprairie.sdstate.edu/etd/5316","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://openprairie.sdstate.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aopenprairie.sdstate.edu%3Aetd-6327","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Dwayne A. Rollag"]},{"key":"dc:creator","label":"Author","values":["Bjerke, Bradley S."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2021-05-28T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["1990-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis - University Access Only"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Civil Engineering","Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://openprairie.sdstate.edu/etd/5316"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Six ozone pilot plant water quality studies were performed on water supplies of five Eastern South Dakota Cities and one Southern Minnesota City. The water supplies for these cities included groundwater at Brookings and Sioux Falls, South Dakota, river water at Huron and Yankton, South Dakota, and lake water at Watertown, South Dakota and Fairmont, Minnesota. The six study sites were investigated by researchers at South Dakota State University, Brookings, South Dakota, and the results are reviewed in this paper. The objective of the studies was to determine optimum ozone dosages and contact times for reducing odors, chlorine demand, organic carbon, trihalomethanes, iron, and manganese. Tests were also done to assess flocculation effects on those plants that depended on settling. The results were utilized to establish capital and operating costs. Test parameters used in the studies included: ozone dosage and contact time, pH, turbidity, odor, temperature, chlorine, absorbance, color, iron, manganese, chemical oxygen demand (COD), and total organic carbon (TOC). The results of ozonation on the varying water supplies were found to be highly dose dependent. Ozonation generally reduced odors, chlorine demand, TOC, trihalomethane formation, and COD levels. Ozonation oxidized iron and manganese, creating fine particle precipitates. The cost of ozonation varied from 6.7 to 33.4 cents per 1,000 gallons of water treated."]},{"key":"dc:title","label":"Title","values":["Ozone Pilot Plant Studies of Six Municipal Water Supplies"]}]}],"canonical_facts":{"dc:contributor":["Dwayne A. Rollag"],"dc:creator":["Bjerke, Bradley S."],"dc:date.available":["2021-05-28T07:00:00Z"],"dc:date.created":["1990-01-01T08:00:00Z"],"dc:description.abstract":["Six ozone pilot plant water quality studies were performed on water supplies of five Eastern South Dakota Cities and one Southern Minnesota City. The water supplies for these cities included groundwater at Brookings and Sioux Falls, South Dakota, river water at Huron and Yankton, South Dakota, and lake water at Watertown, South Dakota and Fairmont, Minnesota. The six study sites were investigated by researchers at South Dakota State University, Brookings, South Dakota, and the results are reviewed in this paper. The objective of the studies was to determine optimum ozone dosages and contact times for reducing odors, chlorine demand, organic carbon, trihalomethanes, iron, and manganese. Tests were also done to assess flocculation effects on those plants that depended on settling. The results were utilized to establish capital and operating costs. Test parameters used in the studies included: ozone dosage and contact time, pH, turbidity, odor, temperature, chlorine, absorbance, color, iron, manganese, chemical oxygen demand (COD), and total organic carbon (TOC). The results of ozonation on the varying water supplies were found to be highly dose dependent. Ozonation generally reduced odors, chlorine demand, TOC, trihalomethane formation, and COD levels. Ozonation oxidized iron and manganese, creating fine particle precipitates. The cost of ozonation varied from 6.7 to 33.4 cents per 1,000 gallons of water treated."],"dc:identifier":["https://openprairie.sdstate.edu/etd/5316"],"dc:language":["English"],"dc:subject":["Civil Engineering","Engineering"],"dc:title":["Ozone Pilot Plant Studies of Six Municipal Water Supplies"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["Thesis - University Access Only"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T09:02:16Z"}