{"id":{"repo_id":"sdstate","oai_identifier":"oai:openprairie.sdstate.edu:etd-6393"},"canonical_url":"https://search.ndltd.org/etd/sdstate/oai:openprairie.sdstate.edu:etd-6393","repository":{"repo_id":"sdstate","name":"South Dakota State University","base_url":"https://openprairie.sdstate.edu/do/oai/"},"display":{"title":"Second Law Analysis in Assessing Heat Dissipating Systems","abstract":"A criterion for comparing the relative performance of various heat transfer augmentation methods used in heat dissipating systems is introduced. The analysis is based on the principle of minimizing the rate of total entropy generation. The heat transfer load (HTL), a parameter determined by the operating requirements of the heat dissipating process and which indicates the difficulty of the heat transfer duty to be perfomed [sic], is defined in the present study. By comparing the irreversibility distribution ratio (ϕ) of various configurations at a given heat transfer load, the most exergy (available energy) efficient system can be selected. The data for three different types of fin configurations used in two common heat dissipation applications (electronic equipment and turbine blade cooling) are utilized in demonstrating the technique. The results indicate which specific fin geometry of the particular configuration type analyzed will transfer the dissipated heat at the specified base surface temperature while requiring the least pumping power. Although the ϕ vs. HTL criterion is applied to extended surfaces only in this study, the method can be extended to many other applications such as jet impingement cooling or mass transfer.","abstract_html":"A criterion for comparing the relative performance of various heat transfer augmentation methods used in heat dissipating systems is introduced. The analysis is based on the principle of minimizing the rate of total entropy generation. The heat transfer load (HTL), a parameter determined by the operating requirements of the heat dissipating process and which indicates the difficulty of the heat transfer duty to be perfomed [sic], is defined in the present study. By comparing the irreversibility distribution ratio (ϕ) of various configurations at a given heat transfer load, the most exergy (available energy) efficient system can be selected. The data for three different types of fin configurations used in two common heat dissipation applications (electronic equipment and turbine blade cooling) are utilized in demonstrating the technique. The results indicate which specific fin geometry of the particular configuration type analyzed will transfer the dissipated heat at the specified base surface temperature while requiring the least pumping power. Although the ϕ vs. HTL criterion is applied to extended surfaces only in this study, the method can be extended to many other applications such as jet impingement cooling or mass transfer.","abstract_has_math":false,"creators":["Wilcoxon, Ross"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis - University Access Only","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["A. Moutsoglou"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:02:16Z","subjects":["Engineering","Mechanical Engineering"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://openprairie.sdstate.edu/etd/5360","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://openprairie.sdstate.edu/etd/5360","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://openprairie.sdstate.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aopenprairie.sdstate.edu%3Aetd-6393","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["A. Moutsoglou"]},{"key":"dc:creator","label":"Author","values":["Wilcoxon, Ross"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2021-06-02T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["1990-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis - University Access Only"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering","Mechanical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://openprairie.sdstate.edu/etd/5360"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A criterion for comparing the relative performance of various heat transfer augmentation methods used in heat dissipating systems is introduced. The analysis is based on the principle of minimizing the rate of total entropy generation. The heat transfer load (HTL), a parameter determined by the operating requirements of the heat dissipating process and which indicates the difficulty of the heat transfer duty to be perfomed [sic], is defined in the present study. By comparing the irreversibility distribution ratio (ϕ) of various configurations at a given heat transfer load, the most exergy (available energy) efficient system can be selected. The data for three different types of fin configurations used in two common heat dissipation applications (electronic equipment and turbine blade cooling) are utilized in demonstrating the technique. The results indicate which specific fin geometry of the particular configuration type analyzed will transfer the dissipated heat at the specified base surface temperature while requiring the least pumping power. Although the ϕ vs. HTL criterion is applied to extended surfaces only in this study, the method can be extended to many other applications such as jet impingement cooling or mass transfer."]},{"key":"dc:title","label":"Title","values":["Second Law Analysis in Assessing Heat Dissipating Systems"]}]}],"canonical_facts":{"dc:contributor":["A. Moutsoglou"],"dc:creator":["Wilcoxon, Ross"],"dc:date.available":["2021-06-02T07:00:00Z"],"dc:date.created":["1990-01-01T08:00:00Z"],"dc:description.abstract":["A criterion for comparing the relative performance of various heat transfer augmentation methods used in heat dissipating systems is introduced. The analysis is based on the principle of minimizing the rate of total entropy generation. The heat transfer load (HTL), a parameter determined by the operating requirements of the heat dissipating process and which indicates the difficulty of the heat transfer duty to be perfomed [sic], is defined in the present study. By comparing the irreversibility distribution ratio (ϕ) of various configurations at a given heat transfer load, the most exergy (available energy) efficient system can be selected. The data for three different types of fin configurations used in two common heat dissipation applications (electronic equipment and turbine blade cooling) are utilized in demonstrating the technique. The results indicate which specific fin geometry of the particular configuration type analyzed will transfer the dissipated heat at the specified base surface temperature while requiring the least pumping power. Although the ϕ vs. HTL criterion is applied to extended surfaces only in this study, the method can be extended to many other applications such as jet impingement cooling or mass transfer."],"dc:identifier":["https://openprairie.sdstate.edu/etd/5360"],"dc:language":["English"],"dc:subject":["Engineering","Mechanical Engineering"],"dc:title":["Second Law Analysis in Assessing Heat Dissipating Systems"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Thesis - University Access Only"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T09:02:16Z"}