{"id":{"repo_id":"sdstate","oai_identifier":"oai:openprairie.sdstate.edu:etd-6973"},"canonical_url":"https://search.ndltd.org/etd/sdstate/oai:openprairie.sdstate.edu:etd-6973","repository":{"repo_id":"sdstate","name":"South Dakota State University","base_url":"https://openprairie.sdstate.edu/do/oai/"},"display":{"title":"The Use of Seepage Meters to Measure Seepage Entering a Gravel Pit","abstract":"The purpose of this study was to determine if seepage meters would provide reliable information on seepage rates in a gravel pit system. Gravel pit systems typically experience high groundwater seepage rates when compared to other surface water systems. Past studies using seepage meters were from water systems that had relatively low seepage rates. The objectives of the study include the following: 1. Construct a seepage meter similar to the meter developed by Lee (5). This study will introduce modifications on the connection between the conduit and the flexible water reservoir, and a larger flexible water reservoir (needed for the larger volumes of water). 2. Determine the proper operation of the seepage meter. Proper operation includes the method of meter placement and the correct procedures for meter operation. 3. Determine the sources of variability associated with the seepage meter and methods to reduce the variability. 4. Determine the effect of seepage rates with various environmental factors. 5. Develop the necessary methods to determine the influx of groundwater into the gravel pit system.","abstract_html":"The purpose of this study was to determine if seepage meters would provide reliable information on seepage rates in a gravel pit system. Gravel pit systems typically experience high groundwater seepage rates when compared to other surface water systems. Past studies using seepage meters were from water systems that had relatively low seepage rates. The objectives of the study include the following: 1. Construct a seepage meter similar to the meter developed by Lee (5). This study will introduce modifications on the connection between the conduit and the flexible water reservoir, and a larger flexible water reservoir (needed for the larger volumes of water). 2. Determine the proper operation of the seepage meter. Proper operation includes the method of meter placement and the correct procedures for meter operation. 3. Determine the sources of variability associated with the seepage meter and methods to reduce the variability. 4. Determine the effect of seepage rates with various environmental factors. 5. Develop the necessary methods to determine the influx of groundwater into the gravel pit system.","abstract_has_math":false,"creators":["Lemke, Chris Alan"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis - University Access Only","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":["James N. Dornbush"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:03:04Z","subjects":["Civil and Environmental Engineering","Civil Engineering","Engineering"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://openprairie.sdstate.edu/etd/5991","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://openprairie.sdstate.edu/etd/5991","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://openprairie.sdstate.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aopenprairie.sdstate.edu%3Aetd-6973","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["James N. Dornbush"]},{"key":"dc:creator","label":"Author","values":["Lemke, Chris Alan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2021-09-24T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["1993-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis - University Access Only"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Civil and Environmental Engineering","Civil Engineering","Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://openprairie.sdstate.edu/etd/5991"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of this study was to determine if seepage meters would provide reliable information on seepage rates in a gravel pit system. Gravel pit systems typically experience high groundwater seepage rates when compared to other surface water systems. Past studies using seepage meters were from water systems that had relatively low seepage rates. The objectives of the study include the following: 1. Construct a seepage meter similar to the meter developed by Lee (5). This study will introduce modifications on the connection between the conduit and the flexible water reservoir, and a larger flexible water reservoir (needed for the larger volumes of water). 2. Determine the proper operation of the seepage meter. Proper operation includes the method of meter placement and the correct procedures for meter operation. 3. Determine the sources of variability associated with the seepage meter and methods to reduce the variability. 4. Determine the effect of seepage rates with various environmental factors. 5. Develop the necessary methods to determine the influx of groundwater into the gravel pit system."]},{"key":"dc:title","label":"Title","values":["The Use of Seepage Meters to Measure Seepage Entering a Gravel Pit"]}]}],"canonical_facts":{"dc:contributor":["James N. Dornbush"],"dc:creator":["Lemke, Chris Alan"],"dc:date.available":["2021-09-24T07:00:00Z"],"dc:date.created":["1993-01-01T08:00:00Z"],"dc:description.abstract":["The purpose of this study was to determine if seepage meters would provide reliable information on seepage rates in a gravel pit system. Gravel pit systems typically experience high groundwater seepage rates when compared to other surface water systems. Past studies using seepage meters were from water systems that had relatively low seepage rates. The objectives of the study include the following: 1. Construct a seepage meter similar to the meter developed by Lee (5). This study will introduce modifications on the connection between the conduit and the flexible water reservoir, and a larger flexible water reservoir (needed for the larger volumes of water). 2. Determine the proper operation of the seepage meter. Proper operation includes the method of meter placement and the correct procedures for meter operation. 3. Determine the sources of variability associated with the seepage meter and methods to reduce the variability. 4. Determine the effect of seepage rates with various environmental factors. 5. Develop the necessary methods to determine the influx of groundwater into the gravel pit system."],"dc:identifier":["https://openprairie.sdstate.edu/etd/5991"],"dc:language":["English"],"dc:subject":["Civil and Environmental Engineering","Civil Engineering","Engineering"],"dc:title":["The Use of Seepage Meters to Measure Seepage Entering a Gravel Pit"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["Thesis - University Access Only"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T09:03:04Z"}