{"id":{"repo_id":"sdstate","oai_identifier":"oai:openprairie.sdstate.edu:etd2-1084"},"canonical_url":"https://search.ndltd.org/etd/sdstate/oai:openprairie.sdstate.edu:etd2-1084","repository":{"repo_id":"sdstate","name":"South Dakota State University","base_url":"https://openprairie.sdstate.edu/do/oai/"},"display":{"title":"The Simultaneous Determination of Thirteen Herbicides in Plants by Gas Chromatography/Mass Spectrometry","abstract":"An analytical method using capillary gas chromatography and mass spectrometry (GC/MS) with selected ion monitoring (SIM) to determine thirteen common herbicide residues( clopyralid, dicamba, MCPA, bromoxynil, 2,4-D, triclopyr, bentazon, DCPA, fluazifop, picloram, acifluorfen, diclofop, fenoxaprop) has been developed. The method involves an alkaline hydrolysis for extracting herbicides from the plant tissue, solvent partitioning into methylene chloride, followed by methylation of the extracted acidic herbicides with diazomethane. Florisil column cleanup was used for the removal of interfering coextractants. Separation and quantification of the herbicides was carried out by capillary GC/MS with SIM. The objective of this research was the development of a simple and efficient method for quantitative multiclass and multiresidue herbicide analysis in plants. An improved Florisil cleanup procedure was developed for removal of many interferences from 13 herbicides that have different structural and polarity properties. The recoveries of residues at the 1 ppm level were 80%-- 95% and at the 0.1 ppm level were 75% --85%. Detection limits were on the range of 0.2 to 0.02 ng depending on the herbicide. This corresponds to about 0.1 ppm to 0.01 ppm in the sample.","abstract_html":"An analytical method using capillary gas chromatography and mass spectrometry (GC/MS) with selected ion monitoring (SIM) to determine thirteen common herbicide residues( clopyralid, dicamba, MCPA, bromoxynil, 2,4-D, triclopyr, bentazon, DCPA, fluazifop, picloram, acifluorfen, diclofop, fenoxaprop) has been developed. The method involves an alkaline hydrolysis for extracting herbicides from the plant tissue, solvent partitioning into methylene chloride, followed by methylation of the extracted acidic herbicides with diazomethane. Florisil column cleanup was used for the removal of interfering coextractants. Separation and quantification of the herbicides was carried out by capillary GC/MS with SIM. The objective of this research was the development of a simple and efficient method for quantitative multiclass and multiresidue herbicide analysis in plants. An improved Florisil cleanup procedure was developed for removal of many interferences from 13 herbicides that have different structural and polarity properties. The recoveries of residues at the 1 ppm level were 80%-- 95% and at the 0.1 ppm level were 75% --85%. Detection limits were on the range of 0.2 to 0.02 ng depending on the herbicide. This corresponds to about 0.1 ppm to 0.01 ppm in the sample.","abstract_has_math":false,"creators":["Wen, Yongkang"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis - University Access Only","degree_discipline":"Chemistry","degree_department":null,"school":null,"contributors":["Duane Matthees"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:03:11Z","subjects":["Chemistry","Physical Sciences and Mathematics"],"languages":["English"],"rights":[],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://openprairie.sdstate.edu/etd2/27","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://openprairie.sdstate.edu/etd2/27","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://openprairie.sdstate.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aopenprairie.sdstate.edu%3Aetd2-1084","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Duane Matthees"]},{"key":"dc:creator","label":"Author","values":["Wen, Yongkang"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2021-10-29T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["1994-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis - University Access Only"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Chemistry","Physical Sciences and Mathematics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://openprairie.sdstate.edu/etd2/27"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An analytical method using capillary gas chromatography and mass spectrometry (GC/MS) with selected ion monitoring (SIM) to determine thirteen common herbicide residues( clopyralid, dicamba, MCPA, bromoxynil, 2,4-D, triclopyr, bentazon, DCPA, fluazifop, picloram, acifluorfen, diclofop, fenoxaprop) has been developed. The method involves an alkaline hydrolysis for extracting herbicides from the plant tissue, solvent partitioning into methylene chloride, followed by methylation of the extracted acidic herbicides with diazomethane. Florisil column cleanup was used for the removal of interfering coextractants. Separation and quantification of the herbicides was carried out by capillary GC/MS with SIM. The objective of this research was the development of a simple and efficient method for quantitative multiclass and multiresidue herbicide analysis in plants. An improved Florisil cleanup procedure was developed for removal of many interferences from 13 herbicides that have different structural and polarity properties. The recoveries of residues at the 1 ppm level were 80%-- 95% and at the 0.1 ppm level were 75% --85%. Detection limits were on the range of 0.2 to 0.02 ng depending on the herbicide. This corresponds to about 0.1 ppm to 0.01 ppm in the sample."]},{"key":"dc:title","label":"Title","values":["The Simultaneous Determination of Thirteen Herbicides in Plants by Gas Chromatography/Mass Spectrometry"]}]}],"canonical_facts":{"dc:contributor":["Duane Matthees"],"dc:creator":["Wen, Yongkang"],"dc:date.available":["2021-10-29T07:00:00Z"],"dc:date.created":["1994-01-01T08:00:00Z"],"dc:description.abstract":["An analytical method using capillary gas chromatography and mass spectrometry (GC/MS) with selected ion monitoring (SIM) to determine thirteen common herbicide residues( clopyralid, dicamba, MCPA, bromoxynil, 2,4-D, triclopyr, bentazon, DCPA, fluazifop, picloram, acifluorfen, diclofop, fenoxaprop) has been developed. The method involves an alkaline hydrolysis for extracting herbicides from the plant tissue, solvent partitioning into methylene chloride, followed by methylation of the extracted acidic herbicides with diazomethane. Florisil column cleanup was used for the removal of interfering coextractants. Separation and quantification of the herbicides was carried out by capillary GC/MS with SIM. The objective of this research was the development of a simple and efficient method for quantitative multiclass and multiresidue herbicide analysis in plants. An improved Florisil cleanup procedure was developed for removal of many interferences from 13 herbicides that have different structural and polarity properties. The recoveries of residues at the 1 ppm level were 80%-- 95% and at the 0.1 ppm level were 75% --85%. Detection limits were on the range of 0.2 to 0.02 ng depending on the herbicide. This corresponds to about 0.1 ppm to 0.01 ppm in the sample."],"dc:identifier":["https://openprairie.sdstate.edu/etd2/27"],"dc:language":["English"],"dc:rights":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Chemistry","Physical Sciences and Mathematics"],"dc:title":["The Simultaneous Determination of Thirteen Herbicides in Plants by Gas Chromatography/Mass Spectrometry"],"thesis:degree_discipline":["Chemistry"],"thesis:degree_level":["Thesis - University Access Only"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T09:03:11Z"}