{"id":{"repo_id":"sdstate","oai_identifier":"oai:openprairie.sdstate.edu:etd2-1117"},"canonical_url":"https://search.ndltd.org/etd/sdstate/oai:openprairie.sdstate.edu:etd2-1117","repository":{"repo_id":"sdstate","name":"South Dakota State University","base_url":"https://openprairie.sdstate.edu/do/oai/"},"display":{"title":"Experiments Designed to Evaluate Insulating Schemes for Slab-on-Grade Hydronic Radiant Floor Heating","abstract":"Common slab-on-grade insulating design practices for Hydronic Radiant Floor Heating (HRFH) vary anywhere from using only vertical insulation completely along the outdoor perimeter, complete vertical insulation and under-floor insulation a short distance in from the outdoor perimeter, and complete vertical and under-floor insulation throughout the entire floor (radiant panels). Additional insulation is one of the most cost contributing factors in this type of installation making it essential to know its effects on energy loss. Experiments were designed which will examine the effects of these insulation schemes on the magnitude of energy lost to the ground for a HRFH system. These experiments were field installed during the construction of a slab-on-grade building which utilizes the concrete floor as radiant panels. The experiment testing outdoor perimeter effects (energy losses outside of footing) was also modeled in the finite element analysis software program SYS. Modeling of the experiment indicated a 21 percent energy savings with the addition of just vertical insulation, up to a maximum of 66 percent energy savings for complete vertical and complete under-floor insulation. Field testing data were also logged and evaluated for this experiment.","abstract_html":"Common slab-on-grade insulating design practices for Hydronic Radiant Floor Heating (HRFH) vary anywhere from using only vertical insulation completely along the outdoor perimeter, complete vertical insulation and under-floor insulation a short distance in from the outdoor perimeter, and complete vertical and under-floor insulation throughout the entire floor (radiant panels). Additional insulation is one of the most cost contributing factors in this type of installation making it essential to know its effects on energy loss. Experiments were designed which will examine the effects of these insulation schemes on the magnitude of energy lost to the ground for a HRFH system. These experiments were field installed during the construction of a slab-on-grade building which utilizes the concrete floor as radiant panels. The experiment testing outdoor perimeter effects (energy losses outside of footing) was also modeled in the finite element analysis software program SYS. Modeling of the experiment indicated a 21 percent energy savings with the addition of just vertical insulation, up to a maximum of 66 percent energy savings for complete vertical and complete under-floor insulation. Field testing data were also logged and evaluated for this experiment.","abstract_has_math":false,"creators":["Jeppesen, Kris"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis - University Access Only","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Charles Remund"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:03:18Z","subjects":["Engineering","Mechanical Engineering"],"languages":["English"],"rights":[],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://openprairie.sdstate.edu/etd2/105","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://openprairie.sdstate.edu/etd2/105","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://openprairie.sdstate.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aopenprairie.sdstate.edu%3Aetd2-1117","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Charles Remund"]},{"key":"dc:creator","label":"Author","values":["Jeppesen, Kris"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2021-11-05T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["1995-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis - University Access Only"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering","Mechanical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://openprairie.sdstate.edu/etd2/105"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Common slab-on-grade insulating design practices for Hydronic Radiant Floor Heating (HRFH) vary anywhere from using only vertical insulation completely along the outdoor perimeter, complete vertical insulation and under-floor insulation a short distance in from the outdoor perimeter, and complete vertical and under-floor insulation throughout the entire floor (radiant panels). Additional insulation is one of the most cost contributing factors in this type of installation making it essential to know its effects on energy loss. Experiments were designed which will examine the effects of these insulation schemes on the magnitude of energy lost to the ground for a HRFH system. These experiments were field installed during the construction of a slab-on-grade building which utilizes the concrete floor as radiant panels. The experiment testing outdoor perimeter effects (energy losses outside of footing) was also modeled in the finite element analysis software program SYS. Modeling of the experiment indicated a 21 percent energy savings with the addition of just vertical insulation, up to a maximum of 66 percent energy savings for complete vertical and complete under-floor insulation. Field testing data were also logged and evaluated for this experiment."]},{"key":"dc:title","label":"Title","values":["Experiments Designed to Evaluate Insulating Schemes for Slab-on-Grade Hydronic Radiant Floor Heating"]}]}],"canonical_facts":{"dc:contributor":["Charles Remund"],"dc:creator":["Jeppesen, Kris"],"dc:date.available":["2021-11-05T07:00:00Z"],"dc:date.created":["1995-01-01T08:00:00Z"],"dc:description.abstract":["Common slab-on-grade insulating design practices for Hydronic Radiant Floor Heating (HRFH) vary anywhere from using only vertical insulation completely along the outdoor perimeter, complete vertical insulation and under-floor insulation a short distance in from the outdoor perimeter, and complete vertical and under-floor insulation throughout the entire floor (radiant panels). Additional insulation is one of the most cost contributing factors in this type of installation making it essential to know its effects on energy loss. Experiments were designed which will examine the effects of these insulation schemes on the magnitude of energy lost to the ground for a HRFH system. These experiments were field installed during the construction of a slab-on-grade building which utilizes the concrete floor as radiant panels. The experiment testing outdoor perimeter effects (energy losses outside of footing) was also modeled in the finite element analysis software program SYS. Modeling of the experiment indicated a 21 percent energy savings with the addition of just vertical insulation, up to a maximum of 66 percent energy savings for complete vertical and complete under-floor insulation. Field testing data were also logged and evaluated for this experiment."],"dc:identifier":["https://openprairie.sdstate.edu/etd2/105"],"dc:language":["English"],"dc:rights":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Engineering","Mechanical Engineering"],"dc:title":["Experiments Designed to Evaluate Insulating Schemes for Slab-on-Grade Hydronic Radiant Floor Heating"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Thesis - University Access Only"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T09:03:18Z"}