{"id":{"repo_id":"sdstate","oai_identifier":"oai:openprairie.sdstate.edu:etd2-1126"},"canonical_url":"https://search.ndltd.org/etd/sdstate/oai:openprairie.sdstate.edu:etd2-1126","repository":{"repo_id":"sdstate","name":"South Dakota State University","base_url":"https://openprairie.sdstate.edu/do/oai/"},"display":{"title":"Thermal Performance of Flowable Fill Mixtures for Horizontal GSHP Systems","abstract":"The goal of this project was to determine the feasibility of using class F flowable fill to backfill horizontal heat exchanger trenches. Crushed quartzite was added in varying degrees to enhance the thermal properties of the mixture. Three phases of testing were conducted to determine the overall performance. Thermal conductivity tests were run to obtain the thermal properties of the mixtures. Shrinkage tests were performed to determine how well the grouts maintained their initial volume. Finally, long term thermal performance tests were run to evaluate how well the mixtures performed under actual thermal loading. The results of the testing show that the thermal conductivity of these mixtures can easily be enhanced with the addition of quartzite. Low shrinkage values were observed in all of the flowable fill mixtures tested. The thermal performance tests indicated that all but one of the mixtures tested held more than fifty percent of their initial water content under the imposed thermal loading. A final mixture of 35 percent fly ash 35 percent quartzite, 25 percent water, and 5 percent portland cement by weight was recommended for backfilling horizontal heat exchanger loops.","abstract_html":"The goal of this project was to determine the feasibility of using class F flowable fill to backfill horizontal heat exchanger trenches. Crushed quartzite was added in varying degrees to enhance the thermal properties of the mixture. Three phases of testing were conducted to determine the overall performance. Thermal conductivity tests were run to obtain the thermal properties of the mixtures. Shrinkage tests were performed to determine how well the grouts maintained their initial volume. Finally, long term thermal performance tests were run to evaluate how well the mixtures performed under actual thermal loading. The results of the testing show that the thermal conductivity of these mixtures can easily be enhanced with the addition of quartzite. Low shrinkage values were observed in all of the flowable fill mixtures tested. The thermal performance tests indicated that all but one of the mixtures tested held more than fifty percent of their initial water content under the imposed thermal loading. A final mixture of 35 percent fly ash 35 percent quartzite, 25 percent water, and 5 percent portland cement by weight was recommended for backfilling horizontal heat exchanger loops.","abstract_has_math":false,"creators":["Lucht, Douglas A."],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis - University Access Only","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Charles Remund"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:03:18Z","subjects":["Engineering","Mechanical Engineering"],"languages":["English"],"rights":[],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://openprairie.sdstate.edu/etd2/142","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://openprairie.sdstate.edu/etd2/142","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://openprairie.sdstate.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aopenprairie.sdstate.edu%3Aetd2-1126","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Charles Remund"]},{"key":"dc:creator","label":"Author","values":["Lucht, Douglas A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2021-11-08T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["1995-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis - University Access Only"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering","Mechanical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://openprairie.sdstate.edu/etd2/142"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The goal of this project was to determine the feasibility of using class F flowable fill to backfill horizontal heat exchanger trenches. Crushed quartzite was added in varying degrees to enhance the thermal properties of the mixture. Three phases of testing were conducted to determine the overall performance. Thermal conductivity tests were run to obtain the thermal properties of the mixtures. Shrinkage tests were performed to determine how well the grouts maintained their initial volume. Finally, long term thermal performance tests were run to evaluate how well the mixtures performed under actual thermal loading. The results of the testing show that the thermal conductivity of these mixtures can easily be enhanced with the addition of quartzite. Low shrinkage values were observed in all of the flowable fill mixtures tested. The thermal performance tests indicated that all but one of the mixtures tested held more than fifty percent of their initial water content under the imposed thermal loading. A final mixture of 35 percent fly ash 35 percent quartzite, 25 percent water, and 5 percent portland cement by weight was recommended for backfilling horizontal heat exchanger loops."]},{"key":"dc:title","label":"Title","values":["Thermal Performance of Flowable Fill Mixtures for Horizontal GSHP Systems"]}]}],"canonical_facts":{"dc:contributor":["Charles Remund"],"dc:creator":["Lucht, Douglas A."],"dc:date.available":["2021-11-08T08:00:00Z"],"dc:date.created":["1995-01-01T08:00:00Z"],"dc:description.abstract":["The goal of this project was to determine the feasibility of using class F flowable fill to backfill horizontal heat exchanger trenches. Crushed quartzite was added in varying degrees to enhance the thermal properties of the mixture. Three phases of testing were conducted to determine the overall performance. Thermal conductivity tests were run to obtain the thermal properties of the mixtures. Shrinkage tests were performed to determine how well the grouts maintained their initial volume. Finally, long term thermal performance tests were run to evaluate how well the mixtures performed under actual thermal loading. The results of the testing show that the thermal conductivity of these mixtures can easily be enhanced with the addition of quartzite. Low shrinkage values were observed in all of the flowable fill mixtures tested. The thermal performance tests indicated that all but one of the mixtures tested held more than fifty percent of their initial water content under the imposed thermal loading. A final mixture of 35 percent fly ash 35 percent quartzite, 25 percent water, and 5 percent portland cement by weight was recommended for backfilling horizontal heat exchanger loops."],"dc:identifier":["https://openprairie.sdstate.edu/etd2/142"],"dc:language":["English"],"dc:rights":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Engineering","Mechanical Engineering"],"dc:title":["Thermal Performance of Flowable Fill Mixtures for Horizontal GSHP Systems"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Thesis - University Access Only"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T09:03:18Z"}