{"id":{"repo_id":"sdstate","oai_identifier":"oai:openprairie.sdstate.edu:etd2-1236"},"canonical_url":"https://search.ndltd.org/etd/sdstate/oai:openprairie.sdstate.edu:etd2-1236","repository":{"repo_id":"sdstate","name":"South Dakota State University","base_url":"https://openprairie.sdstate.edu/do/oai/"},"display":{"title":"Modified PWM Technique for Reduction of Voltage Harmonic Distortion Using AC-AC Converter","abstract":"The proliferation of nonlinear loads such as static power converters and arc furnaces has produced a variety of undesirable phenomena in the operation of power systems. Often, the most important among these are harmonic distortion, increased reactive power demand and power system voltage oscillations. Harmonic distortion has become a major concern for power system experts due to its effects on sensitive loads and on the power distribution system. Many loads draw significant harmonic currents that cause voltage distortion at points of common coupling. Historically, passive LC filters followed by shunt active filters using PWM inverters have been developed and studied for reduction of harmonic components and to improve the power factor. However, certain problems, particularly resonance, instability and sensitivity to noise and temperature, have persisted. This thesis addresses the problem of line voltage distortion at a point of common coupling (PCC) by installing an AC-AC voltage converter between the PCC and the sensitive equipment. The AC-AC buck converter was considered. Sinusoidal PWM of the duty ratio of the AC-AC buck converter isolated the sensitive equipment from the harmonic components of the line voltage at the PCC. The influence of varying the switching frequency on the efficiency of the buck converter as a harmonic isolator was also studied. The validity of applying the AC-AC voltage converters for isolating the harmonic components of the line voltage at the PCC from the sensitive equipment has been established through MATLAB simulation.","abstract_html":"The proliferation of nonlinear loads such as static power converters and arc furnaces has produced a variety of undesirable phenomena in the operation of power systems. Often, the most important among these are harmonic distortion, increased reactive power demand and power system voltage oscillations. Harmonic distortion has become a major concern for power system experts due to its effects on sensitive loads and on the power distribution system. Many loads draw significant harmonic currents that cause voltage distortion at points of common coupling. Historically, passive LC filters followed by shunt active filters using PWM inverters have been developed and studied for reduction of harmonic components and to improve the power factor. However, certain problems, particularly resonance, instability and sensitivity to noise and temperature, have persisted. This thesis addresses the problem of line voltage distortion at a point of common coupling (PCC) by installing an AC-AC voltage converter between the PCC and the sensitive equipment. The AC-AC buck converter was considered. Sinusoidal PWM of the duty ratio of the AC-AC buck converter isolated the sensitive equipment from the harmonic components of the line voltage at the PCC. The influence of varying the switching frequency on the efficiency of the buck converter as a harmonic isolator was also studied. The validity of applying the AC-AC voltage converters for isolating the harmonic components of the line voltage at the PCC from the sensitive equipment has been established through MATLAB simulation.","abstract_has_math":false,"creators":["Tejwani, Udaya Kumar"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis - University Access Only","degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":["S.M. Hietpas"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:03:24Z","subjects":["Electrical and Computer Engineering","Engineering"],"languages":["English"],"rights":[],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://openprairie.sdstate.edu/etd2/246","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://openprairie.sdstate.edu/etd2/246","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://openprairie.sdstate.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aopenprairie.sdstate.edu%3Aetd2-1236","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["S.M. Hietpas"]},{"key":"dc:creator","label":"Author","values":["Tejwani, Udaya Kumar"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2021-12-17T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["1996-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis - University Access Only"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical and Computer Engineering","Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://openprairie.sdstate.edu/etd2/246"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The proliferation of nonlinear loads such as static power converters and arc furnaces has produced a variety of undesirable phenomena in the operation of power systems. Often, the most important among these are harmonic distortion, increased reactive power demand and power system voltage oscillations. Harmonic distortion has become a major concern for power system experts due to its effects on sensitive loads and on the power distribution system. Many loads draw significant harmonic currents that cause voltage distortion at points of common coupling. Historically, passive LC filters followed by shunt active filters using PWM inverters have been developed and studied for reduction of harmonic components and to improve the power factor. However, certain problems, particularly resonance, instability and sensitivity to noise and temperature, have persisted. This thesis addresses the problem of line voltage distortion at a point of common coupling (PCC) by installing an AC-AC voltage converter between the PCC and the sensitive equipment. The AC-AC buck converter was considered. Sinusoidal PWM of the duty ratio of the AC-AC buck converter isolated the sensitive equipment from the harmonic components of the line voltage at the PCC. The influence of varying the switching frequency on the efficiency of the buck converter as a harmonic isolator was also studied. The validity of applying the AC-AC voltage converters for isolating the harmonic components of the line voltage at the PCC from the sensitive equipment has been established through MATLAB simulation."]},{"key":"dc:title","label":"Title","values":["Modified PWM Technique for Reduction of Voltage Harmonic Distortion Using AC-AC Converter"]}]}],"canonical_facts":{"dc:contributor":["S.M. Hietpas"],"dc:creator":["Tejwani, Udaya Kumar"],"dc:date.available":["2021-12-17T08:00:00Z"],"dc:date.created":["1996-01-01T08:00:00Z"],"dc:description.abstract":["The proliferation of nonlinear loads such as static power converters and arc furnaces has produced a variety of undesirable phenomena in the operation of power systems. Often, the most important among these are harmonic distortion, increased reactive power demand and power system voltage oscillations. Harmonic distortion has become a major concern for power system experts due to its effects on sensitive loads and on the power distribution system. Many loads draw significant harmonic currents that cause voltage distortion at points of common coupling. Historically, passive LC filters followed by shunt active filters using PWM inverters have been developed and studied for reduction of harmonic components and to improve the power factor. However, certain problems, particularly resonance, instability and sensitivity to noise and temperature, have persisted. This thesis addresses the problem of line voltage distortion at a point of common coupling (PCC) by installing an AC-AC voltage converter between the PCC and the sensitive equipment. The AC-AC buck converter was considered. Sinusoidal PWM of the duty ratio of the AC-AC buck converter isolated the sensitive equipment from the harmonic components of the line voltage at the PCC. The influence of varying the switching frequency on the efficiency of the buck converter as a harmonic isolator was also studied. The validity of applying the AC-AC voltage converters for isolating the harmonic components of the line voltage at the PCC from the sensitive equipment has been established through MATLAB simulation."],"dc:identifier":["https://openprairie.sdstate.edu/etd2/246"],"dc:language":["English"],"dc:rights":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Electrical and Computer Engineering","Engineering"],"dc:title":["Modified PWM Technique for Reduction of Voltage Harmonic Distortion Using AC-AC Converter"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Thesis - University Access Only"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T09:03:24Z"}