{"id":{"repo_id":"sdstate","oai_identifier":"oai:openprairie.sdstate.edu:etd2-1544"},"canonical_url":"https://search.ndltd.org/etd/sdstate/oai:openprairie.sdstate.edu:etd2-1544","repository":{"repo_id":"sdstate","name":"South Dakota State University","base_url":"https://openprairie.sdstate.edu/do/oai/"},"display":{"title":"The Effect of Grout Thermal Conductivity on Vertical Geothermal Heat Exchanger Design and Performance","abstract":"The objective of this research was to determine the effect of grout thermal conductivity on the design and performance of vertical geothermal heat exchanger loops. The steady-state grout thermal resistance was found experimentally and b using A SYS finite element analysis modeling. A multiple regression model was developed from the experimental results. The ANSYS results were correlated to using shape factors. Grout thermal resistance values from the experimental model were used with software packages GchpCalc and GLHEPRO, and the IGSHP A vertical loop design equations to estimate the effect of grout thermal conductivity on design loop length. Total loop length reductions of up to 15% to 25% were found. The effect of grout conductivity on vertical loop installation costs was estimated by comparing designs from GchpCalc for regular bentonite grout and for grout containing 50% sand for thermal enhancement. For a 15% reduction in heat exchanger design length a 14.2% cost savings was estimated for the heat exchanger installation. It was also shown that, for a given heat exchanger design􁅑 use of thermally enhanced grout instead to regular bentonite grout will result in better heat pump performance and lower operating costs.","abstract_html":"The objective of this research was to determine the effect of grout thermal conductivity on the design and performance of vertical geothermal heat exchanger loops. The steady-state grout thermal resistance was found experimentally and b using A SYS finite element analysis modeling. A multiple regression model was developed from the experimental results. The ANSYS results were correlated to using shape factors. Grout thermal resistance values from the experimental model were used with software packages GchpCalc and GLHEPRO, and the IGSHP A vertical loop design equations to estimate the effect of grout thermal conductivity on design loop length. Total loop length reductions of up to 15% to 25% were found. The effect of grout conductivity on vertical loop installation costs was estimated by comparing designs from GchpCalc for regular bentonite grout and for grout containing 50% sand for thermal enhancement. For a 15% reduction in heat exchanger design length a 14.2% cost savings was estimated for the heat exchanger installation. It was also shown that, for a given heat exchanger design􁅑 use of thermally enhanced grout instead to regular bentonite grout will result in better heat pump performance and lower operating costs.","abstract_has_math":false,"creators":["Paul, Neal D."],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis - University Access Only","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:03:44Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://openprairie.sdstate.edu/etd2/542","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://openprairie.sdstate.edu/etd2/542","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://openprairie.sdstate.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aopenprairie.sdstate.edu%3Aetd2-1544","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Paul, Neal D."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2023-03-13T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["1996-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis - University Access Only"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://openprairie.sdstate.edu/etd2/542"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The objective of this research was to determine the effect of grout thermal conductivity on the design and performance of vertical geothermal heat exchanger loops. The steady-state grout thermal resistance was found experimentally and b using A SYS finite element analysis modeling. A multiple regression model was developed from the experimental results. The ANSYS results were correlated to using shape factors. Grout thermal resistance values from the experimental model were used with software packages GchpCalc and GLHEPRO, and the IGSHP A vertical loop design equations to estimate the effect of grout thermal conductivity on design loop length. Total loop length reductions of up to 15% to 25% were found. The effect of grout conductivity on vertical loop installation costs was estimated by comparing designs from GchpCalc for regular bentonite grout and for grout containing 50% sand for thermal enhancement. For a 15% reduction in heat exchanger design length a 14.2% cost savings was estimated for the heat exchanger installation. It was also shown that, for a given heat exchanger design􁅑 use of thermally enhanced grout instead to regular bentonite grout will result in better heat pump performance and lower operating costs."]},{"key":"dc:title","label":"Title","values":["The Effect of Grout Thermal Conductivity on Vertical Geothermal Heat Exchanger Design and Performance"]}]}],"canonical_facts":{"dc:creator":["Paul, Neal D."],"dc:date.available":["2023-03-13T07:00:00Z"],"dc:date.created":["1996-01-01T08:00:00Z"],"dc:description.abstract":["The objective of this research was to determine the effect of grout thermal conductivity on the design and performance of vertical geothermal heat exchanger loops. The steady-state grout thermal resistance was found experimentally and b using A SYS finite element analysis modeling. A multiple regression model was developed from the experimental results. The ANSYS results were correlated to using shape factors. Grout thermal resistance values from the experimental model were used with software packages GchpCalc and GLHEPRO, and the IGSHP A vertical loop design equations to estimate the effect of grout thermal conductivity on design loop length. Total loop length reductions of up to 15% to 25% were found. The effect of grout conductivity on vertical loop installation costs was estimated by comparing designs from GchpCalc for regular bentonite grout and for grout containing 50% sand for thermal enhancement. For a 15% reduction in heat exchanger design length a 14.2% cost savings was estimated for the heat exchanger installation. It was also shown that, for a given heat exchanger design􁅑 use of thermally enhanced grout instead to regular bentonite grout will result in better heat pump performance and lower operating costs."],"dc:identifier":["https://openprairie.sdstate.edu/etd2/542"],"dc:title":["The Effect of Grout Thermal Conductivity on Vertical Geothermal Heat Exchanger Design and Performance"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Thesis - University Access Only"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T09:03:44Z"}