{"id":{"repo_id":"sdstate","oai_identifier":"oai:openprairie.sdstate.edu:etd2-2028"},"canonical_url":"https://search.ndltd.org/etd/sdstate/oai:openprairie.sdstate.edu:etd2-2028","repository":{"repo_id":"sdstate","name":"South Dakota State University","base_url":"https://openprairie.sdstate.edu/do/oai/"},"display":{"title":"LANDSAT 5 Characterization Of Outgassing Effects On The Thematic Mapper Cold Focal Plane","abstract":"Detector responses in Bands 5 and 7 to the Internal Calibrator in the Landsat 5 Thematic Mapper vary over time. The observed variations are sinusoidal in nature, and believed to be caused by a time-dependent material accumulation on a window of the cold focal plane dewar containing the detectors. These changes in responses, referred to as outgassing effects, have been previously modeled, but corrections using those models were unsatisfactory. A new thin-film interference model has been developed that accounts for these effects. The model is based on analysis of three closely sampled sets of detector responses throughout the instrument's lifetime, and relates detector behavior to the accumulated material thickness, which depends on the interval since the previous outgassing event as well as the film growth rate. Corrections using this new model were found to improve the radiometric calibration of Bands 5 and 7 by approximately 3 percent.","abstract_html":"Detector responses in Bands 5 and 7 to the Internal Calibrator in the Landsat 5 Thematic Mapper vary over time. The observed variations are sinusoidal in nature, and believed to be caused by a time-dependent material accumulation on a window of the cold focal plane dewar containing the detectors. These changes in responses, referred to as outgassing effects, have been previously modeled, but corrections using those models were unsatisfactory. A new thin-film interference model has been developed that accounts for these effects. The model is based on analysis of three closely sampled sets of detector responses throughout the instrument&#x27;s lifetime, and relates detector behavior to the accumulated material thickness, which depends on the interval since the previous outgassing event as well as the film growth rate. Corrections using this new model were found to improve the radiometric calibration of Bands 5 and 7 by approximately 3 percent.","abstract_has_math":false,"creators":["Micijevic, Esad"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis - University Access Only","degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":["Dennis Helder"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:04:25Z","subjects":[],"languages":[],"rights":[],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://openprairie.sdstate.edu/etd2/1028","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://openprairie.sdstate.edu/etd2/1028","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://openprairie.sdstate.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aopenprairie.sdstate.edu%3Aetd2-2028","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Dennis Helder"]},{"key":"dc:creator","label":"Author","values":["Micijevic, Esad"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2024-06-12T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2003-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis - University Access Only"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://openprairie.sdstate.edu/etd2/1028"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Detector responses in Bands 5 and 7 to the Internal Calibrator in the Landsat 5 Thematic Mapper vary over time. The observed variations are sinusoidal in nature, and believed to be caused by a time-dependent material accumulation on a window of the cold focal plane dewar containing the detectors. These changes in responses, referred to as outgassing effects, have been previously modeled, but corrections using those models were unsatisfactory. A new thin-film interference model has been developed that accounts for these effects. The model is based on analysis of three closely sampled sets of detector responses throughout the instrument's lifetime, and relates detector behavior to the accumulated material thickness, which depends on the interval since the previous outgassing event as well as the film growth rate. Corrections using this new model were found to improve the radiometric calibration of Bands 5 and 7 by approximately 3 percent."]},{"key":"dc:title","label":"Title","values":["LANDSAT 5 Characterization Of Outgassing Effects On The Thematic Mapper Cold Focal Plane"]}]}],"canonical_facts":{"dc:contributor":["Dennis Helder"],"dc:creator":["Micijevic, Esad"],"dc:date.available":["2024-06-12T07:00:00Z"],"dc:date.created":["2003-01-01T08:00:00Z"],"dc:description.abstract":["Detector responses in Bands 5 and 7 to the Internal Calibrator in the Landsat 5 Thematic Mapper vary over time. The observed variations are sinusoidal in nature, and believed to be caused by a time-dependent material accumulation on a window of the cold focal plane dewar containing the detectors. These changes in responses, referred to as outgassing effects, have been previously modeled, but corrections using those models were unsatisfactory. A new thin-film interference model has been developed that accounts for these effects. The model is based on analysis of three closely sampled sets of detector responses throughout the instrument's lifetime, and relates detector behavior to the accumulated material thickness, which depends on the interval since the previous outgassing event as well as the film growth rate. Corrections using this new model were found to improve the radiometric calibration of Bands 5 and 7 by approximately 3 percent."],"dc:identifier":["https://openprairie.sdstate.edu/etd2/1028"],"dc:rights":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["LANDSAT 5 Characterization Of Outgassing Effects On The Thematic Mapper Cold Focal Plane"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Thesis - University Access Only"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T09:04:25Z"}