{"id":{"repo_id":"sdstate","oai_identifier":"oai:openprairie.sdstate.edu:etd2-2285"},"canonical_url":"https://search.ndltd.org/etd/sdstate/oai:openprairie.sdstate.edu:etd2-2285","repository":{"repo_id":"sdstate","name":"South Dakota State University","base_url":"https://openprairie.sdstate.edu/do/oai/"},"display":{"title":"Annual, Monthly and Daily Pan Evaporation Maps for the State of South Dakota","abstract":"The design of waste stabilization and retention ponds is affected by evaporation, which is a key parameter that determines the volume and footprint of these systems. It impacts the design life and operation of such systems. Underdesigning of such ponds can potentially lead to adverse impacts upon the environment and over designing leads to financial loss. Determination of the pan evaporation throughout the state of South Dakota was the main objective of this study. The available pan evaporation stations are widely scattered and have incomplete records of data, necessitating a means of interpreting, adjusting and extending pan evaporation was a part of the objective. Missing data were interpolated using statistical analysis. Based on a literature search and statistical analysis, the best evaporation model was applied and calibrated with existing pan evaporation and meteorological data. The model was verified by comparing field pan evaporation with predicted pan evaporation values. The model was then used to compute spatial estimates of pan evaporation anywhere in the state of South Dakota. The pan evaporation stations from neighboring states were included in the research to give a realistic view to pan evaporation contours, and also to serve as boundary conditions. The pan evaporation maps were presented in both paper and digital format. Arc View® 3.2 was used to illustrate the maps. The exceedence levels were calculated at the 10t\\ 2 5 t\\ sot\\ 75 th and 90th percentiles to assign some level of risk to pan evaporation values.","abstract_html":"The design of waste stabilization and retention ponds is affected by evaporation, which is a key parameter that determines the volume and footprint of these systems. It impacts the design life and operation of such systems. Underdesigning of such ponds can potentially lead to adverse impacts upon the environment and over designing leads to financial loss. Determination of the pan evaporation throughout the state of South Dakota was the main objective of this study. The available pan evaporation stations are widely scattered and have incomplete records of data, necessitating a means of interpreting, adjusting and extending pan evaporation was a part of the objective. Missing data were interpolated using statistical analysis. Based on a literature search and statistical analysis, the best evaporation model was applied and calibrated with existing pan evaporation and meteorological data. The model was verified by comparing field pan evaporation with predicted pan evaporation values. The model was then used to compute spatial estimates of pan evaporation anywhere in the state of South Dakota. The pan evaporation stations from neighboring states were included in the research to give a realistic view to pan evaporation contours, and also to serve as boundary conditions. The pan evaporation maps were presented in both paper and digital format. Arc View® 3.2 was used to illustrate the maps. The exceedence levels were calculated at the 10t\\ 2 5 t\\ sot\\ 75 th and 90th percentiles to assign some level of risk to pan evaporation values.","abstract_has_math":false,"creators":["Poudyal, Sudarshan"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis - University Access Only","degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:05:14Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://openprairie.sdstate.edu/etd2/1281","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://openprairie.sdstate.edu/etd2/1281","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://openprairie.sdstate.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aopenprairie.sdstate.edu%3Aetd2-2285","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Poudyal, Sudarshan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2024-11-12T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2006-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis - University Access Only"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://openprairie.sdstate.edu/etd2/1281"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The design of waste stabilization and retention ponds is affected by evaporation, which is a key parameter that determines the volume and footprint of these systems. It impacts the design life and operation of such systems. Underdesigning of such ponds can potentially lead to adverse impacts upon the environment and over designing leads to financial loss. Determination of the pan evaporation throughout the state of South Dakota was the main objective of this study. The available pan evaporation stations are widely scattered and have incomplete records of data, necessitating a means of interpreting, adjusting and extending pan evaporation was a part of the objective. Missing data were interpolated using statistical analysis. Based on a literature search and statistical analysis, the best evaporation model was applied and calibrated with existing pan evaporation and meteorological data. The model was verified by comparing field pan evaporation with predicted pan evaporation values. The model was then used to compute spatial estimates of pan evaporation anywhere in the state of South Dakota. The pan evaporation stations from neighboring states were included in the research to give a realistic view to pan evaporation contours, and also to serve as boundary conditions. The pan evaporation maps were presented in both paper and digital format. Arc View® 3.2 was used to illustrate the maps. The exceedence levels were calculated at the 10t\\ 2 5 t\\ sot\\ 75 th and 90th percentiles to assign some level of risk to pan evaporation values."]},{"key":"dc:title","label":"Title","values":["Annual, Monthly and Daily Pan Evaporation Maps for the State of South Dakota"]}]}],"canonical_facts":{"dc:creator":["Poudyal, Sudarshan"],"dc:date.available":["2024-11-12T08:00:00Z"],"dc:date.created":["2006-01-01T08:00:00Z"],"dc:description.abstract":["The design of waste stabilization and retention ponds is affected by evaporation, which is a key parameter that determines the volume and footprint of these systems. It impacts the design life and operation of such systems. Underdesigning of such ponds can potentially lead to adverse impacts upon the environment and over designing leads to financial loss. Determination of the pan evaporation throughout the state of South Dakota was the main objective of this study. The available pan evaporation stations are widely scattered and have incomplete records of data, necessitating a means of interpreting, adjusting and extending pan evaporation was a part of the objective. Missing data were interpolated using statistical analysis. Based on a literature search and statistical analysis, the best evaporation model was applied and calibrated with existing pan evaporation and meteorological data. The model was verified by comparing field pan evaporation with predicted pan evaporation values. The model was then used to compute spatial estimates of pan evaporation anywhere in the state of South Dakota. The pan evaporation stations from neighboring states were included in the research to give a realistic view to pan evaporation contours, and also to serve as boundary conditions. The pan evaporation maps were presented in both paper and digital format. Arc View® 3.2 was used to illustrate the maps. The exceedence levels were calculated at the 10t\\ 2 5 t\\ sot\\ 75 th and 90th percentiles to assign some level of risk to pan evaporation values."],"dc:identifier":["https://openprairie.sdstate.edu/etd2/1281"],"dc:title":["Annual, Monthly and Daily Pan Evaporation Maps for the State of South Dakota"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_level":["Thesis - University Access Only"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T09:05:14Z"}