{"id":{"repo_id":"sdstate","oai_identifier":"oai:openprairie.sdstate.edu:etd2-2513"},"canonical_url":"https://search.ndltd.org/etd/sdstate/oai:openprairie.sdstate.edu:etd2-2513","repository":{"repo_id":"sdstate","name":"South Dakota State University","base_url":"https://openprairie.sdstate.edu/do/oai/"},"display":{"title":"Refinement Of Trend-To-Trend Cross Calibration Total Uncertainties Utilizing Extended Pseudo Invariant Calibration Sites (Epics) Global Temporally Stable Target","abstract":"Cross-calibration is an essential technique for calibrating Earth Observation satellite sensors, which involves taking nearly simultaneous images of a ground target to compare uncalibrated sensor to a well-calibrated reference sensor. This study introduces the hyperspectral Trend-to-Trend (T2T) cross-calibration technique utilizing EPICS Cluster 13 Global Temporally Stable (Cluster 13-GTS) as the calibration target, offering better temporal stability than previous targets used in T2T cross-calibration by an absolute difference of 0.4%, between coefficients of variation across all bands excluding CA band. A multispectral sensor-specific normalized hyperspectral profile was developed using the EO-1 Hyperion hyperspectral profile over Cluster 13-GTS to improve Spectral Band Adjustment Factor (SBAF) estimation, capturing sensor-specific Relative Spectral Response (RSR) variations and introducing the ability to use the multispectral sensorspecific hyperspectral profile for calibrating future satellite sensors like Landsat Next with super-spectral bands. SBAFs were derived from EO-1 Hyperion normalized to multispectral sensors, which were interpolated to 1nm, ensuring precise spectral band adjustments following a Monte Carlo simulation approach for uncertainty quantification. Results show that reference sensor-specific hyperspectral profiles at 1nm spectral resolution improve SBAF accuracy and exhibit total uncertainty within 5.8% across all bands and all sensor pairs with L8 as the reference sensor. These findings demonstrate that integrating reference sensor-specific high-resolution hyperspectral data and stable calibration targets im-proves T2T cross-calibration accuracy, supporting future superspectral missions such as Landsat Next.","abstract_html":"Cross-calibration is an essential technique for calibrating Earth Observation satellite sensors, which involves taking nearly simultaneous images of a ground target to compare uncalibrated sensor to a well-calibrated reference sensor. This study introduces the hyperspectral Trend-to-Trend (T2T) cross-calibration technique utilizing EPICS Cluster 13 Global Temporally Stable (Cluster 13-GTS) as the calibration target, offering better temporal stability than previous targets used in T2T cross-calibration by an absolute difference of 0.4%, between coefficients of variation across all bands excluding CA band. A multispectral sensor-specific normalized hyperspectral profile was developed using the EO-1 Hyperion hyperspectral profile over Cluster 13-GTS to improve Spectral Band Adjustment Factor (SBAF) estimation, capturing sensor-specific Relative Spectral Response (RSR) variations and introducing the ability to use the multispectral sensorspecific hyperspectral profile for calibrating future satellite sensors like Landsat Next with super-spectral bands. SBAFs were derived from EO-1 Hyperion normalized to multispectral sensors, which were interpolated to 1nm, ensuring precise spectral band adjustments following a Monte Carlo simulation approach for uncertainty quantification. Results show that reference sensor-specific hyperspectral profiles at 1nm spectral resolution improve SBAF accuracy and exhibit total uncertainty within 5.8% across all bands and all sensor pairs with L8 as the reference sensor. These findings demonstrate that integrating reference sensor-specific high-resolution hyperspectral data and stable calibration targets im-proves T2T cross-calibration accuracy, supporting future superspectral missions such as Landsat Next.","abstract_has_math":false,"creators":["Samaranayake, Minura"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis - Open Access","degree_discipline":"Electrical Engineering and Computer Science","degree_department":null,"school":null,"contributors":["Larry Leigh"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:05:56Z","subjects":["Electrical and Computer Engineering"],"languages":[],"rights":[],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://openprairie.sdstate.edu/etd2/1540","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://openprairie.sdstate.edu/etd2/1540","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://openprairie.sdstate.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aopenprairie.sdstate.edu%3Aetd2-2513","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Larry Leigh"]},{"key":"dc:creator","label":"Author","values":["Samaranayake, Minura"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2025-12-15T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering and Computer Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis - Open Access"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical and Computer Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://openprairie.sdstate.edu/etd2/1540"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Cross-calibration is an essential technique for calibrating Earth Observation satellite sensors, which involves taking nearly simultaneous images of a ground target to compare uncalibrated sensor to a well-calibrated reference sensor. This study introduces the hyperspectral Trend-to-Trend (T2T) cross-calibration technique utilizing EPICS Cluster 13 Global Temporally Stable (Cluster 13-GTS) as the calibration target, offering better temporal stability than previous targets used in T2T cross-calibration by an absolute difference of 0.4%, between coefficients of variation across all bands excluding CA band. A multispectral sensor-specific normalized hyperspectral profile was developed using the EO-1 Hyperion hyperspectral profile over Cluster 13-GTS to improve Spectral Band Adjustment Factor (SBAF) estimation, capturing sensor-specific Relative Spectral Response (RSR) variations and introducing the ability to use the multispectral sensorspecific hyperspectral profile for calibrating future satellite sensors like Landsat Next with super-spectral bands. SBAFs were derived from EO-1 Hyperion normalized to multispectral sensors, which were interpolated to 1nm, ensuring precise spectral band adjustments following a Monte Carlo simulation approach for uncertainty quantification. Results show that reference sensor-specific hyperspectral profiles at 1nm spectral resolution improve SBAF accuracy and exhibit total uncertainty within 5.8% across all bands and all sensor pairs with L8 as the reference sensor. These findings demonstrate that integrating reference sensor-specific high-resolution hyperspectral data and stable calibration targets im-proves T2T cross-calibration accuracy, supporting future superspectral missions such as Landsat Next."]},{"key":"dc:title","label":"Title","values":["Refinement Of Trend-To-Trend Cross Calibration Total Uncertainties Utilizing Extended Pseudo Invariant Calibration Sites (Epics) Global Temporally Stable Target"]}]}],"canonical_facts":{"dc:contributor":["Larry Leigh"],"dc:creator":["Samaranayake, Minura"],"dc:date.available":["2025-12-15T08:00:00Z"],"dc:date.created":["2025-01-01T08:00:00Z"],"dc:description.abstract":["Cross-calibration is an essential technique for calibrating Earth Observation satellite sensors, which involves taking nearly simultaneous images of a ground target to compare uncalibrated sensor to a well-calibrated reference sensor. This study introduces the hyperspectral Trend-to-Trend (T2T) cross-calibration technique utilizing EPICS Cluster 13 Global Temporally Stable (Cluster 13-GTS) as the calibration target, offering better temporal stability than previous targets used in T2T cross-calibration by an absolute difference of 0.4%, between coefficients of variation across all bands excluding CA band. A multispectral sensor-specific normalized hyperspectral profile was developed using the EO-1 Hyperion hyperspectral profile over Cluster 13-GTS to improve Spectral Band Adjustment Factor (SBAF) estimation, capturing sensor-specific Relative Spectral Response (RSR) variations and introducing the ability to use the multispectral sensorspecific hyperspectral profile for calibrating future satellite sensors like Landsat Next with super-spectral bands. SBAFs were derived from EO-1 Hyperion normalized to multispectral sensors, which were interpolated to 1nm, ensuring precise spectral band adjustments following a Monte Carlo simulation approach for uncertainty quantification. Results show that reference sensor-specific hyperspectral profiles at 1nm spectral resolution improve SBAF accuracy and exhibit total uncertainty within 5.8% across all bands and all sensor pairs with L8 as the reference sensor. These findings demonstrate that integrating reference sensor-specific high-resolution hyperspectral data and stable calibration targets im-proves T2T cross-calibration accuracy, supporting future superspectral missions such as Landsat Next."],"dc:identifier":["https://openprairie.sdstate.edu/etd2/1540"],"dc:rights":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Electrical and Computer Engineering"],"dc:title":["Refinement Of Trend-To-Trend Cross Calibration Total Uncertainties Utilizing Extended Pseudo Invariant Calibration Sites (Epics) Global Temporally Stable Target"],"thesis:degree_discipline":["Electrical Engineering and Computer Science"],"thesis:degree_level":["Thesis - Open Access"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T09:05:56Z"}