{"id":{"repo_id":"sevilla","oai_identifier":"oai:idus.us.es:11441/188840"},"canonical_url":"https://search.ndltd.org/etd/sevilla/oai:idus.us.es:11441/188840","repository":{"repo_id":"sevilla","name":"Universidad de Sevilla","base_url":"https://idus.us.es/server/oai/request"},"display":{"title":"Monte Carlo Methods for Advancing Ophthalmic Brachytherapy: From Accurate Personalized Dosimetry to Novel Therapeutic Strategies","abstract":"Ophthalmic brachytherapy is a cornerstone treatment for selected intraocular tumors, offering high rates of local control while preserving the eye and, in many cases, useful vision. However, its clinical effectiveness is strongly conditioned by the accuracy of dose calculation in an anatomical scenario characterized by small dimensions, steep dose gradients, and the presence of strong heterogeneities. Conventional treatment planning approaches, largely based on water-equivalent formalisms and empirical corrections, are limited in their ability to fully capture these complexities, potentially contributing to uncertainties in tumor coverage and normal-tissue toxicity. This doctoral thesis investigates the role of Monte Carlo methods to advance ophthalmic brachytherapy from both a dosimetric and a radiobiological perspective. First, detailed Monte Carlo models of clinically used ophthalmic applicators are developed and validated, including COMS-type plaques loaded with 125I seeds and 106Ru/106Rh beta-emitting plaques, with particular emphasis on asymmetric geometries specifically designed to spare critical eye structures. These simulations enable a rigorous characterization of dose distributions and a quantitative comparison with treatment-planning system predictions. Second, these models are consolidated into EyeMC, a dedicated Monte Carlo-based dose calculation system designed to reproduce patient-specific ocular plaque treatments planned in clinical practice, thereby enabling independent verification and three-dimensional analysis of delivered dose distributions. Beyond dosimetry, the thesis explores novel therapeutic strategies based on gold nanoparticle-mediated radiosensitization for ophthalmic 125I brachytherapy. A multiscale methodology is presented that combines Monte Carlo simulations, from the macroscopic scale down to cellular and nanometric track-structure radiation-matter interaction modeling, with experimental in vitro assays, including γH2AX and clonogenic survival analyses, to investigate the magnitude and underlying mechanisms of AuNP-induced enhancement. The results demonstrate notable physical dose enhancement and pronounced radiosensitization under the studied conditions. Overall, this work establishes Monte Carlo simulation as a key enabling technology for the next generation of ophthalmic brachytherapy, facilitating improved dosimetric accuracy, patient-specific treatment calculations, and the rational development of innovative radiosensitization approaches.","abstract_html":"Ophthalmic brachytherapy is a cornerstone treatment for selected intraocular tumors, offering high rates of local control while preserving the eye and, in many cases, useful vision. However, its clinical effectiveness is strongly conditioned by the accuracy of dose calculation in an anatomical scenario characterized by small dimensions, steep dose gradients, and the presence of strong heterogeneities. Conventional treatment planning approaches, largely based on water-equivalent formalisms and empirical corrections, are limited in their ability to fully capture these complexities, potentially contributing to uncertainties in tumor coverage and normal-tissue toxicity. This doctoral thesis investigates the role of Monte Carlo methods to advance ophthalmic brachytherapy from both a dosimetric and a radiobiological perspective. First, detailed Monte Carlo models of clinically used ophthalmic applicators are developed and validated, including COMS-type plaques loaded with 125I seeds and 106Ru/106Rh beta-emitting plaques, with particular emphasis on asymmetric geometries specifically designed to spare critical eye structures. These simulations enable a rigorous characterization of dose distributions and a quantitative comparison with treatment-planning system predictions. Second, these models are consolidated into EyeMC, a dedicated Monte Carlo-based dose calculation system designed to reproduce patient-specific ocular plaque treatments planned in clinical practice, thereby enabling independent verification and three-dimensional analysis of delivered dose distributions. Beyond dosimetry, the thesis explores novel therapeutic strategies based on gold nanoparticle-mediated radiosensitization for ophthalmic 125I brachytherapy. A multiscale methodology is presented that combines Monte Carlo simulations, from the macroscopic scale down to cellular and nanometric track-structure radiation-matter interaction modeling, with experimental in vitro assays, including γH2AX and clonogenic survival analyses, to investigate the magnitude and underlying mechanisms of AuNP-induced enhancement. The results demonstrate notable physical dose enhancement and pronounced radiosensitization under the studied conditions. Overall, this work establishes Monte Carlo simulation as a key enabling technology for the next generation of ophthalmic brachytherapy, facilitating improved dosimetric accuracy, patient-specific treatment calculations, and the rational development of innovative radiosensitization approaches.","abstract_has_math":false,"creators":["Miras del Río, Héctor"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Leal Plaza, Antonio"],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026-06-19","date_published":"2026-06-19","updated_at":"2026-11-19T07:51:19Z","subjects":[],"languages":["eng"],"rights":["open access","Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Miras del Río, H. (2026). Monte Carlo Methods for Advancing Ophthalmic Brachytherapy: From Accurate Personalized Dosimetry to Novel Therapeutic Strategies. (Tesis Doctoral Inédita). Universidad de Sevilla, Sevilla."],"render_values":[{"text":"Miras del Río, H. (2026). Monte Carlo Methods for Advancing Ophthalmic Brachytherapy: From Accurate Personalized Dosimetry to Novel Therapeutic Strategies. (Tesis Doctoral Inédita). Universidad de Sevilla, Sevilla.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11441/188840","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11441/188840","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":"open","embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Asevilla%3Aoai%3Aidus.us.es%3A11441%2F188840","prefix":"oai_dc"},"source_record":{"url":"https://idus.us.es/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aidus.us.es%3A11441%2F188840","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Leal Plaza, Antonio"]},{"key":"dc:creator","label":"Author","values":["Miras del Río, Héctor"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-08-04T10:02:19Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-08-04T10:02:19Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-06-19"]},{"key":"dc:type","label":"Dc Type","values":["tesis doctoral"]},{"key":"dc:type.version","label":"Dc Type Version","values":["VoR"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NonCommercial-NoDerivatives 4.0 International"]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["open access"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Miras del Río, H. (2026). Monte Carlo Methods for Advancing Ophthalmic Brachytherapy: From Accurate Personalized Dosimetry to Novel Therapeutic Strategies. (Tesis Doctoral Inédita). Universidad de Sevilla, Sevilla."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/11441/188840"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Ophthalmic brachytherapy is a cornerstone treatment for selected intraocular tumors, offering high rates of local control while preserving the eye and, in many cases, useful vision. However, its clinical effectiveness is strongly conditioned by the accuracy of dose calculation in an anatomical scenario characterized by small dimensions, steep dose gradients, and the presence of strong heterogeneities. Conventional treatment planning approaches, largely based on water-equivalent formalisms and empirical corrections, are limited in their ability to fully capture these complexities, potentially contributing to uncertainties in tumor coverage and normal-tissue toxicity. This doctoral thesis investigates the role of Monte Carlo methods to advance ophthalmic brachytherapy from both a dosimetric and a radiobiological perspective. First, detailed Monte Carlo models of clinically used ophthalmic applicators are developed and validated, including COMS-type plaques loaded with 125I seeds and 106Ru/106Rh beta-emitting plaques, with particular emphasis on asymmetric geometries specifically designed to spare critical eye structures. These simulations enable a rigorous characterization of dose distributions and a quantitative comparison with treatment-planning system predictions. Second, these models are consolidated into EyeMC, a dedicated Monte Carlo-based dose calculation system designed to reproduce patient-specific ocular plaque treatments planned in clinical practice, thereby enabling independent verification and three-dimensional analysis of delivered dose distributions. Beyond dosimetry, the thesis explores novel therapeutic strategies based on gold nanoparticle-mediated radiosensitization for ophthalmic 125I brachytherapy. A multiscale methodology is presented that combines Monte Carlo simulations, from the macroscopic scale down to cellular and nanometric track-structure radiation-matter interaction modeling, with experimental in vitro assays, including γH2AX and clonogenic survival analyses, to investigate the magnitude and underlying mechanisms of AuNP-induced enhancement. The results demonstrate notable physical dose enhancement and pronounced radiosensitization under the studied conditions. Overall, this work establishes Monte Carlo simulation as a key enabling technology for the next generation of ophthalmic brachytherapy, facilitating improved dosimetric accuracy, patient-specific treatment calculations, and the rational development of innovative radiosensitization approaches."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["220 p."]},{"key":"dc:title","label":"Title","values":["Monte Carlo Methods for Advancing Ophthalmic Brachytherapy: From Accurate Personalized Dosimetry to Novel Therapeutic Strategies"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Fisiología Médica y Biofísica"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Leal Plaza, Antonio"],"dc:creator":["Miras del Río, Héctor"],"dc:date.accessioned":["2026-08-04T10:02:19Z"],"dc:date.available":["2026-08-04T10:02:19Z"],"dc:date.issued":["2026-06-19"],"dc:description.abstract":["Ophthalmic brachytherapy is a cornerstone treatment for selected intraocular tumors, offering high rates of local control while preserving the eye and, in many cases, useful vision. However, its clinical effectiveness is strongly conditioned by the accuracy of dose calculation in an anatomical scenario characterized by small dimensions, steep dose gradients, and the presence of strong heterogeneities. Conventional treatment planning approaches, largely based on water-equivalent formalisms and empirical corrections, are limited in their ability to fully capture these complexities, potentially contributing to uncertainties in tumor coverage and normal-tissue toxicity. This doctoral thesis investigates the role of Monte Carlo methods to advance ophthalmic brachytherapy from both a dosimetric and a radiobiological perspective. First, detailed Monte Carlo models of clinically used ophthalmic applicators are developed and validated, including COMS-type plaques loaded with 125I seeds and 106Ru/106Rh beta-emitting plaques, with particular emphasis on asymmetric geometries specifically designed to spare critical eye structures. These simulations enable a rigorous characterization of dose distributions and a quantitative comparison with treatment-planning system predictions. Second, these models are consolidated into EyeMC, a dedicated Monte Carlo-based dose calculation system designed to reproduce patient-specific ocular plaque treatments planned in clinical practice, thereby enabling independent verification and three-dimensional analysis of delivered dose distributions. Beyond dosimetry, the thesis explores novel therapeutic strategies based on gold nanoparticle-mediated radiosensitization for ophthalmic 125I brachytherapy. A multiscale methodology is presented that combines Monte Carlo simulations, from the macroscopic scale down to cellular and nanometric track-structure radiation-matter interaction modeling, with experimental in vitro assays, including γH2AX and clonogenic survival analyses, to investigate the magnitude and underlying mechanisms of AuNP-induced enhancement. The results demonstrate notable physical dose enhancement and pronounced radiosensitization under the studied conditions. Overall, this work establishes Monte Carlo simulation as a key enabling technology for the next generation of ophthalmic brachytherapy, facilitating improved dosimetric accuracy, patient-specific treatment calculations, and the rational development of innovative radiosensitization approaches."],"dc:format":["application/pdf"],"dc:format.extent":["220 p."],"dc:identifier.citation":["Miras del Río, H. (2026). Monte Carlo Methods for Advancing Ophthalmic Brachytherapy: From Accurate Personalized Dosimetry to Novel Therapeutic Strategies. (Tesis Doctoral Inédita). Universidad de Sevilla, Sevilla."],"dc:identifier.uri":["https://hdl.handle.net/11441/188840"],"dc:language.iso":["eng"],"dc:rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:rights.accessrights":["open access"],"dc:rights.uri":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"dc:title":["Monte Carlo Methods for Advancing Ophthalmic Brachytherapy: From Accurate Personalized Dosimetry to Novel Therapeutic Strategies"],"dc:type":["tesis doctoral"],"dc:type.version":["VoR"],"local:contributor.affiliation":["Fisiología Médica y Biofísica"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T07:51:19Z"}