{"id":{"repo_id":"sjsu","oai_identifier":"oai:scholarworks.sjsu.edu:etd_theses-4750"},"canonical_url":"https://search.ndltd.org/etd/sjsu/oai:scholarworks.sjsu.edu:etd_theses-4750","repository":{"repo_id":"sjsu","name":"San Jose State University","base_url":"https://scholarworks.sjsu.edu/do/oai/"},"display":{"title":"Nonlinear Pushover Analysis of a One-Story Precast Concrete Cladding System","abstract":"A nonlinear pushover analytical study of a precast concrete cladding system was completed. The analytical software used was SAP2000 (version 11.0.0). The specimen modeled is the three-dimensional corner of the first floor of a nine-story building. Thirty-one linear and nonlinear link elements were used to simulate the cladding connections. The results showed that inelastic behavior of these connections controls the behavior of the overall cladding system. At drift ratios of 0.0104, closure of the sliding connections at the top of the column cover panels occurs and resisting forces climb significantly with small additional lateral displacement. Forces quickly rise to levels indicating failure of the connections between the column covers and the foundation. At drift ratios of 0.0111, failure of the foundation connections is expected to occur, likely leading to instability of the panels.","abstract_html":"A nonlinear pushover analytical study of a precast concrete cladding system was completed. The analytical software used was SAP2000 (version 11.0.0). The specimen modeled is the three-dimensional corner of the first floor of a nine-story building. Thirty-one linear and nonlinear link elements were used to simulate the cladding connections. The results showed that inelastic behavior of these connections controls the behavior of the overall cladding system. At drift ratios of 0.0104, closure of the sliding connections at the top of the column cover panels occurs and resisting forces climb significantly with small additional lateral displacement. Forces quickly rise to levels indicating failure of the connections between the column covers and the foundation. At drift ratios of 0.0111, failure of the foundation connections is expected to occur, likely leading to instability of the panels.","abstract_has_math":false,"creators":["Cheung, Kai Sum"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":null,"degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["Kurt McMullin"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T13:59:13Z","subjects":["Analysis","Cladding","Non-Linear","Pushover","SAP2000","Seismic"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarworks.sjsu.edu/etd_theses/3754"],"render_values":[{"text":"https://scholarworks.sjsu.edu/etd_theses/3754","href":"https://scholarworks.sjsu.edu/etd_theses/3754","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.31979/etd.mghv-cf6p","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.31979/etd.mghv-cf6p","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Asjsu%3Aoai%3Ascholarworks.sjsu.edu%3Aetd_theses-4750","prefix":"oai_dc"},"source_record":{"url":"https://scholarworks.sjsu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarworks.sjsu.edu%3Aetd_theses-4750","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Kurt McMullin"]},{"key":"dc:creator","label":"Author","values":["Cheung, Kai Sum"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2010-01-01T08:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Analysis","Cladding","Non-Linear","Pushover","SAP2000","Seismic"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.31979/etd.mghv-cf6p","https://scholarworks.sjsu.edu/etd_theses/3754"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A nonlinear pushover analytical study of a precast concrete cladding system was completed. The analytical software used was SAP2000 (version 11.0.0). The specimen modeled is the three-dimensional corner of the first floor of a nine-story building. Thirty-one linear and nonlinear link elements were used to simulate the cladding connections. The results showed that inelastic behavior of these connections controls the behavior of the overall cladding system. At drift ratios of 0.0104, closure of the sliding connections at the top of the column cover panels occurs and resisting forces climb significantly with small additional lateral displacement. Forces quickly rise to levels indicating failure of the connections between the column covers and the foundation. At drift ratios of 0.0111, failure of the foundation connections is expected to occur, likely leading to instability of the panels."]},{"key":"dc:title","label":"Title","values":["Nonlinear Pushover Analysis of a One-Story Precast Concrete Cladding System"]}]}],"canonical_facts":{"dc:contributor":["Kurt McMullin"],"dc:creator":["Cheung, Kai Sum"],"dc:date.created":["2010-01-01T08:00:00Z"],"dc:description.abstract":["A nonlinear pushover analytical study of a precast concrete cladding system was completed. The analytical software used was SAP2000 (version 11.0.0). The specimen modeled is the three-dimensional corner of the first floor of a nine-story building. Thirty-one linear and nonlinear link elements were used to simulate the cladding connections. The results showed that inelastic behavior of these connections controls the behavior of the overall cladding system. At drift ratios of 0.0104, closure of the sliding connections at the top of the column cover panels occurs and resisting forces climb significantly with small additional lateral displacement. Forces quickly rise to levels indicating failure of the connections between the column covers and the foundation. At drift ratios of 0.0111, failure of the foundation connections is expected to occur, likely leading to instability of the panels."],"dc:identifier":["https://doi.org/10.31979/etd.mghv-cf6p","https://scholarworks.sjsu.edu/etd_theses/3754"],"dc:subject":["Analysis","Cladding","Non-Linear","Pushover","SAP2000","Seismic"],"dc:title":["Nonlinear Pushover Analysis of a One-Story Precast Concrete Cladding System"],"dc:type":["Thesis"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-26T13:59:13Z"}