{"id":{"repo_id":"sjsu","oai_identifier":"oai:scholarworks.sjsu.edu:etd_theses-4780"},"canonical_url":"https://search.ndltd.org/etd/sjsu/oai:scholarworks.sjsu.edu:etd_theses-4780","repository":{"repo_id":"sjsu","name":"San Jose State University","base_url":"https://scholarworks.sjsu.edu/do/oai/"},"display":{"title":"Acoustic Intensity Measurement System: Application in Localized Drug Delivery","abstract":"Ultrasound is used for many applications in diagnostics and therapy. New developments are being made specifically for the use of therapeutic ultrasound for enhancement of localized drug delivery. The long term goal of this study is to find ultrasound pulsing sequences that will allow for controlled mass diffusion from hydrogel drug reservoirs. Developing this new method requires the calibration and characterization of therapy transducers using power and acoustic intensity measurements. Mechanical index, spatial peak pulse average intensity, and spatial temporal pulse average intensity calculations were made using hydrophone measurements set-up in a tank measurement system. These were compared to safety limits defined by the Food and Drug Administration. With these calculated safety values, preliminary tissue mimicking phantom measurements were made to verify the possible efficacy of the new method. The membrane of the microcapsule bulged under continuous sonication from the transducer. Further investigation is needed to identify the mechanisms responsible for this effect.","abstract_html":"Ultrasound is used for many applications in diagnostics and therapy. New developments are being made specifically for the use of therapeutic ultrasound for enhancement of localized drug delivery. The long term goal of this study is to find ultrasound pulsing sequences that will allow for controlled mass diffusion from hydrogel drug reservoirs. Developing this new method requires the calibration and characterization of therapy transducers using power and acoustic intensity measurements. Mechanical index, spatial peak pulse average intensity, and spatial temporal pulse average intensity calculations were made using hydrophone measurements set-up in a tank measurement system. These were compared to safety limits defined by the Food and Drug Administration. With these calculated safety values, preliminary tissue mimicking phantom measurements were made to verify the possible efficacy of the new method. The membrane of the microcapsule bulged under continuous sonication from the transducer. Further investigation is needed to identify the mechanisms responsible for this effect.","abstract_has_math":false,"creators":["Phipps, Natalie"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":null,"degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":["Mallika Keralapura"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T13:59:13Z","subjects":["Acoustic Intensity","Drug Delivery","Microcapsule","Ultrasound"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarworks.sjsu.edu/etd_theses/3784"],"render_values":[{"text":"https://scholarworks.sjsu.edu/etd_theses/3784","href":"https://scholarworks.sjsu.edu/etd_theses/3784","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.31979/etd.g9sp-chpd","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.31979/etd.g9sp-chpd","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Asjsu%3Aoai%3Ascholarworks.sjsu.edu%3Aetd_theses-4780","prefix":"oai_dc"},"source_record":{"url":"https://scholarworks.sjsu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarworks.sjsu.edu%3Aetd_theses-4780","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Mallika Keralapura"]},{"key":"dc:creator","label":"Author","values":["Phipps, Natalie"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2010-01-01T08:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Acoustic Intensity","Drug Delivery","Microcapsule","Ultrasound"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.31979/etd.g9sp-chpd","https://scholarworks.sjsu.edu/etd_theses/3784"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Ultrasound is used for many applications in diagnostics and therapy. New developments are being made specifically for the use of therapeutic ultrasound for enhancement of localized drug delivery. The long term goal of this study is to find ultrasound pulsing sequences that will allow for controlled mass diffusion from hydrogel drug reservoirs. Developing this new method requires the calibration and characterization of therapy transducers using power and acoustic intensity measurements. Mechanical index, spatial peak pulse average intensity, and spatial temporal pulse average intensity calculations were made using hydrophone measurements set-up in a tank measurement system. These were compared to safety limits defined by the Food and Drug Administration. With these calculated safety values, preliminary tissue mimicking phantom measurements were made to verify the possible efficacy of the new method. The membrane of the microcapsule bulged under continuous sonication from the transducer. Further investigation is needed to identify the mechanisms responsible for this effect."]},{"key":"dc:title","label":"Title","values":["Acoustic Intensity Measurement System: Application in Localized Drug Delivery"]}]}],"canonical_facts":{"dc:contributor":["Mallika Keralapura"],"dc:creator":["Phipps, Natalie"],"dc:date.created":["2010-01-01T08:00:00Z"],"dc:description.abstract":["Ultrasound is used for many applications in diagnostics and therapy. New developments are being made specifically for the use of therapeutic ultrasound for enhancement of localized drug delivery. The long term goal of this study is to find ultrasound pulsing sequences that will allow for controlled mass diffusion from hydrogel drug reservoirs. Developing this new method requires the calibration and characterization of therapy transducers using power and acoustic intensity measurements. Mechanical index, spatial peak pulse average intensity, and spatial temporal pulse average intensity calculations were made using hydrophone measurements set-up in a tank measurement system. These were compared to safety limits defined by the Food and Drug Administration. With these calculated safety values, preliminary tissue mimicking phantom measurements were made to verify the possible efficacy of the new method. The membrane of the microcapsule bulged under continuous sonication from the transducer. Further investigation is needed to identify the mechanisms responsible for this effect."],"dc:identifier":["https://doi.org/10.31979/etd.g9sp-chpd","https://scholarworks.sjsu.edu/etd_theses/3784"],"dc:subject":["Acoustic Intensity","Drug Delivery","Microcapsule","Ultrasound"],"dc:title":["Acoustic Intensity Measurement System: Application in Localized Drug Delivery"],"dc:type":["Thesis"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-26T13:59:13Z"}