{"id":{"repo_id":"sjsu","oai_identifier":"oai:scholarworks.sjsu.edu:etd_theses-5067"},"canonical_url":"https://search.ndltd.org/etd/sjsu/oai:scholarworks.sjsu.edu:etd_theses-5067","repository":{"repo_id":"sjsu","name":"San Jose State University","base_url":"https://scholarworks.sjsu.edu/do/oai/"},"display":{"title":"Profiling miniaturized separation media by micro infrared spectroscopy","abstract":"Separation methods have been miniaturized in recent years. Capillary electrophoresis is now common and other types of analyses are being done on microfluidic chips with capillary channels in lieu of wider column diameters. The surfaces of the media used for separation are chemically modified. Using infrared spectroscopy by a microscope attachment, attempts were made to characterize the surfaces of both capillary channels and modified polymer for microfluidic chips. FTIR microscopy is not common in this type of analysis and is normally used to analyze particles, such as fibers, paint, and other polymer sources. Since modification of miniaturized chemical media is done on a microscopic scale, the FTIR microscope seemed promising for the detection of these changes. However, there was great difficulty in detecting the target material against the background material. Thus, micro-infrared spectroscopy is not an ideal method for characterizing modified separation media, despite its ability to sample small areas. Additionally, a novel medium for microfluidic chips, a material made of polymethylhydrosiloxane (PMHS), was described. PMHS has an advantage over other chip media in that the surface can be chemically modified, similar to capillary electrophoresis.","abstract_html":"Separation methods have been miniaturized in recent years. Capillary electrophoresis is now common and other types of analyses are being done on microfluidic chips with capillary channels in lieu of wider column diameters. The surfaces of the media used for separation are chemically modified. Using infrared spectroscopy by a microscope attachment, attempts were made to characterize the surfaces of both capillary channels and modified polymer for microfluidic chips. FTIR microscopy is not common in this type of analysis and is normally used to analyze particles, such as fibers, paint, and other polymer sources. Since modification of miniaturized chemical media is done on a microscopic scale, the FTIR microscope seemed promising for the detection of these changes. However, there was great difficulty in detecting the target material against the background material. Thus, micro-infrared spectroscopy is not an ideal method for characterizing modified separation media, despite its ability to sample small areas. Additionally, a novel medium for microfluidic chips, a material made of polymethylhydrosiloxane (PMHS), was described. PMHS has an advantage over other chip media in that the surface can be chemically modified, similar to capillary electrophoresis.","abstract_has_math":false,"creators":["Perttula, Kelsi Michel"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":null,"degree_discipline":"Chemistry","degree_department":null,"school":null,"contributors":["Joseph Pesek"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T13:59:36Z","subjects":["capillary electrophoresis","FTIR microscopy","hydrosilation","microfluidic chips","silanization"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarworks.sjsu.edu/etd_theses/4069"],"render_values":[{"text":"https://scholarworks.sjsu.edu/etd_theses/4069","href":"https://scholarworks.sjsu.edu/etd_theses/4069","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.31979/etd.q7um-zumz","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.31979/etd.q7um-zumz","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Asjsu%3Aoai%3Ascholarworks.sjsu.edu%3Aetd_theses-5067","prefix":"oai_dc"},"source_record":{"url":"https://scholarworks.sjsu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarworks.sjsu.edu%3Aetd_theses-5067","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Joseph Pesek"]},{"key":"dc:creator","label":"Author","values":["Perttula, Kelsi Michel"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2011-01-01T08:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["capillary electrophoresis","FTIR microscopy","hydrosilation","microfluidic chips","silanization"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.31979/etd.q7um-zumz","https://scholarworks.sjsu.edu/etd_theses/4069"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Separation methods have been miniaturized in recent years. Capillary electrophoresis is now common and other types of analyses are being done on microfluidic chips with capillary channels in lieu of wider column diameters. The surfaces of the media used for separation are chemically modified. Using infrared spectroscopy by a microscope attachment, attempts were made to characterize the surfaces of both capillary channels and modified polymer for microfluidic chips. FTIR microscopy is not common in this type of analysis and is normally used to analyze particles, such as fibers, paint, and other polymer sources. Since modification of miniaturized chemical media is done on a microscopic scale, the FTIR microscope seemed promising for the detection of these changes. However, there was great difficulty in detecting the target material against the background material. Thus, micro-infrared spectroscopy is not an ideal method for characterizing modified separation media, despite its ability to sample small areas. Additionally, a novel medium for microfluidic chips, a material made of polymethylhydrosiloxane (PMHS), was described. PMHS has an advantage over other chip media in that the surface can be chemically modified, similar to capillary electrophoresis."]},{"key":"dc:title","label":"Title","values":["Profiling miniaturized separation media by micro infrared spectroscopy"]}]}],"canonical_facts":{"dc:contributor":["Joseph Pesek"],"dc:creator":["Perttula, Kelsi Michel"],"dc:date.created":["2011-01-01T08:00:00Z"],"dc:description.abstract":["Separation methods have been miniaturized in recent years. Capillary electrophoresis is now common and other types of analyses are being done on microfluidic chips with capillary channels in lieu of wider column diameters. The surfaces of the media used for separation are chemically modified. Using infrared spectroscopy by a microscope attachment, attempts were made to characterize the surfaces of both capillary channels and modified polymer for microfluidic chips. FTIR microscopy is not common in this type of analysis and is normally used to analyze particles, such as fibers, paint, and other polymer sources. Since modification of miniaturized chemical media is done on a microscopic scale, the FTIR microscope seemed promising for the detection of these changes. However, there was great difficulty in detecting the target material against the background material. Thus, micro-infrared spectroscopy is not an ideal method for characterizing modified separation media, despite its ability to sample small areas. Additionally, a novel medium for microfluidic chips, a material made of polymethylhydrosiloxane (PMHS), was described. PMHS has an advantage over other chip media in that the surface can be chemically modified, similar to capillary electrophoresis."],"dc:identifier":["https://doi.org/10.31979/etd.q7um-zumz","https://scholarworks.sjsu.edu/etd_theses/4069"],"dc:subject":["capillary electrophoresis","FTIR microscopy","hydrosilation","microfluidic chips","silanization"],"dc:title":["Profiling miniaturized separation media by micro infrared spectroscopy"],"dc:type":["Thesis"],"thesis:degree_discipline":["Chemistry"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-26T13:59:36Z"}