{"id":{"repo_id":"sjsu","oai_identifier":"oai:scholarworks.sjsu.edu:etd_theses-7918"},"canonical_url":"https://search.ndltd.org/etd/sjsu/oai:scholarworks.sjsu.edu:etd_theses-7918","repository":{"repo_id":"sjsu","name":"San Jose State University","base_url":"https://scholarworks.sjsu.edu/do/oai/"},"display":{"title":"Real-time Auto Tuning of a Closed Loop Second Order System with Internal Time Delay Using Pseudo Random Binary Sequences","abstract":"This research yielded a real-time auto tuning algorithm to adaptively tune a proportional integral and derivative (PID) controller for a first or second-order system with internal time-delay. The method uses a 15-bit pseudo-random binary sequence as an input to obtain the closed-loop system impulse response while the system is operating. Time-delay is assessed by analysis of the estimated closed-loop impulse response and is used in the system model for closed-loop pole assessment. The fast fourier transform of the estimated impulse response produces an estimate of the frequency response data, and a non-linear regression optimization technique, utilizing MATLAB, identifies the closed-loop system transfer function based on assumed form. Closed-loop poles are then placed, based on an iterative tuning study, automatically by the algorithm to achieve a user-defined overshoot and ensure stability of the system with time-delay. This is accomplished by adjusting the PID compensator gains. The algorithm is capable of tuning the system from an initially stable set of PID gains to within 5% of the user-defined overshoot. The research demonstrates that the auto tuning method is feasible for time-delays on the order of the plant time constant but is extendable to larger time-delays.","abstract_html":"This research yielded a real-time auto tuning algorithm to adaptively tune a proportional integral and derivative (PID) controller for a first or second-order system with internal time-delay. The method uses a 15-bit pseudo-random binary sequence as an input to obtain the closed-loop system impulse response while the system is operating. Time-delay is assessed by analysis of the estimated closed-loop impulse response and is used in the system model for closed-loop pole assessment. The fast fourier transform of the estimated impulse response produces an estimate of the frequency response data, and a non-linear regression optimization technique, utilizing MATLAB, identifies the closed-loop system transfer function based on assumed form. Closed-loop poles are then placed, based on an iterative tuning study, automatically by the algorithm to achieve a user-defined overshoot and ensure stability of the system with time-delay. This is accomplished by adjusting the PID compensator gains. The algorithm is capable of tuning the system from an initially stable set of PID gains to within 5% of the user-defined overshoot. The research demonstrates that the auto tuning method is feasible for time-delays on the order of the plant time constant but is extendable to larger time-delays.","abstract_has_math":false,"creators":["Adams, David"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":null,"degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":["Peter Reischl"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T13:59:59Z","subjects":["Controls"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarworks.sjsu.edu/etd_theses/4371"],"render_values":[{"text":"https://scholarworks.sjsu.edu/etd_theses/4371","href":"https://scholarworks.sjsu.edu/etd_theses/4371","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.31979/etd.x2vp-ab9a","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.31979/etd.x2vp-ab9a","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Asjsu%3Aoai%3Ascholarworks.sjsu.edu%3Aetd_theses-7918","prefix":"oai_dc"},"source_record":{"url":"https://scholarworks.sjsu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarworks.sjsu.edu%3Aetd_theses-7918","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Peter Reischl"]},{"key":"dc:creator","label":"Author","values":["Adams, David"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2013-01-01T08:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Controls"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.31979/etd.x2vp-ab9a","https://scholarworks.sjsu.edu/etd_theses/4371"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This research yielded a real-time auto tuning algorithm to adaptively tune a proportional integral and derivative (PID) controller for a first or second-order system with internal time-delay. The method uses a 15-bit pseudo-random binary sequence as an input to obtain the closed-loop system impulse response while the system is operating. Time-delay is assessed by analysis of the estimated closed-loop impulse response and is used in the system model for closed-loop pole assessment. The fast fourier transform of the estimated impulse response produces an estimate of the frequency response data, and a non-linear regression optimization technique, utilizing MATLAB, identifies the closed-loop system transfer function based on assumed form. Closed-loop poles are then placed, based on an iterative tuning study, automatically by the algorithm to achieve a user-defined overshoot and ensure stability of the system with time-delay. This is accomplished by adjusting the PID compensator gains. The algorithm is capable of tuning the system from an initially stable set of PID gains to within 5% of the user-defined overshoot. The research demonstrates that the auto tuning method is feasible for time-delays on the order of the plant time constant but is extendable to larger time-delays."]},{"key":"dc:title","label":"Title","values":["Real-time Auto Tuning of a Closed Loop Second Order System with Internal Time Delay Using Pseudo Random Binary Sequences"]}]}],"canonical_facts":{"dc:contributor":["Peter Reischl"],"dc:creator":["Adams, David"],"dc:date.created":["2013-01-01T08:00:00Z"],"dc:description.abstract":["This research yielded a real-time auto tuning algorithm to adaptively tune a proportional integral and derivative (PID) controller for a first or second-order system with internal time-delay. The method uses a 15-bit pseudo-random binary sequence as an input to obtain the closed-loop system impulse response while the system is operating. Time-delay is assessed by analysis of the estimated closed-loop impulse response and is used in the system model for closed-loop pole assessment. The fast fourier transform of the estimated impulse response produces an estimate of the frequency response data, and a non-linear regression optimization technique, utilizing MATLAB, identifies the closed-loop system transfer function based on assumed form. Closed-loop poles are then placed, based on an iterative tuning study, automatically by the algorithm to achieve a user-defined overshoot and ensure stability of the system with time-delay. This is accomplished by adjusting the PID compensator gains. The algorithm is capable of tuning the system from an initially stable set of PID gains to within 5% of the user-defined overshoot. The research demonstrates that the auto tuning method is feasible for time-delays on the order of the plant time constant but is extendable to larger time-delays."],"dc:identifier":["https://doi.org/10.31979/etd.x2vp-ab9a","https://scholarworks.sjsu.edu/etd_theses/4371"],"dc:subject":["Controls"],"dc:title":["Real-time Auto Tuning of a Closed Loop Second Order System with Internal Time Delay Using Pseudo Random Binary Sequences"],"dc:type":["Thesis"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-26T13:59:59Z"}