{"id":{"repo_id":"sjsu","oai_identifier":"oai:scholarworks.sjsu.edu:etd_theses-8352"},"canonical_url":"https://search.ndltd.org/etd/sjsu/oai:scholarworks.sjsu.edu:etd_theses-8352","repository":{"repo_id":"sjsu","name":"San Jose State University","base_url":"https://scholarworks.sjsu.edu/do/oai/"},"display":{"title":"Development of DNA assembly and error correction protocols for a digital microfluidic device","abstract":"Customized production of synthetic DNA from oligonucleotides is in high demand. However, current technologies are costly and labor-intensive. A microfluidic technology can significantly decrease cost and labor. The purpose of this study was to develop a gene assembly protocol that was utilized on the Mondrian™ SP digital microfluidic device. The fragment of the human influenza virus hemagglutinin (HA) gene (339 bp) was assembled from 12 oligonucleotides by the Gibson assembly method and error corrected with CorrectASE™ enzyme twice. The samples were analyzed by Sanger sequencing to verify the final accuracy of the assembly. A complete automation of droplet generation and movement on digital microfluidic droplet technology was achieved in the study. The reactions were scaled down to 0.6-1.2 µL. Gibson assembly, PCR, and enzymatic error correction reactions were optimized and combined in a single protocol. The microfluidic assembly demonstrated approximately 3 errors/kb error frequency. Polymerase chain reaction supplemented with additional MgCl2, Phusion, and PEG 8000 provided amplification of the assembly and error correction products. The lowest error frequency of 0.3 errors/kb was achieved after one CorrectASE™ treatment. However, microfluidic error correction was not reliable due to CorrectASE™ interactions with the microfluidic surface, which need to be the subject of future work.","abstract_html":"Customized production of synthetic DNA from oligonucleotides is in high demand. However, current technologies are costly and labor-intensive. A microfluidic technology can significantly decrease cost and labor. The purpose of this study was to develop a gene assembly protocol that was utilized on the Mondrian™ SP digital microfluidic device. The fragment of the human influenza virus hemagglutinin (HA) gene (339 bp) was assembled from 12 oligonucleotides by the Gibson assembly method and error corrected with CorrectASE™ enzyme twice. The samples were analyzed by Sanger sequencing to verify the final accuracy of the assembly. A complete automation of droplet generation and movement on digital microfluidic droplet technology was achieved in the study. The reactions were scaled down to 0.6-1.2 µL. Gibson assembly, PCR, and enzymatic error correction reactions were optimized and combined in a single protocol. The microfluidic assembly demonstrated approximately 3 errors/kb error frequency. Polymerase chain reaction supplemented with additional MgCl2, Phusion, and PEG 8000 provided amplification of the assembly and error correction products. The lowest error frequency of 0.3 errors/kb was achieved after one CorrectASE™ treatment. However, microfluidic error correction was not reliable due to CorrectASE™ interactions with the microfluidic surface, which need to be the subject of future work.","abstract_has_math":false,"creators":["Khilko, Yuliya"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":null,"degree_discipline":"Biomedical, Chemical & Materials Engineering","degree_department":null,"school":null,"contributors":["Melanie McNeil"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T14:00:31Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarworks.sjsu.edu/etd_theses/4805"],"render_values":[{"text":"https://scholarworks.sjsu.edu/etd_theses/4805","href":"https://scholarworks.sjsu.edu/etd_theses/4805","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.31979/etd.uys4-w4m9","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.31979/etd.uys4-w4m9","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Asjsu%3Aoai%3Ascholarworks.sjsu.edu%3Aetd_theses-8352","prefix":"oai_dc"},"source_record":{"url":"https://scholarworks.sjsu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarworks.sjsu.edu%3Aetd_theses-8352","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Melanie McNeil"]},{"key":"dc:creator","label":"Author","values":["Khilko, Yuliya"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2017-12-23T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2017-01-01T08:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical, Chemical & Materials Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.31979/etd.uys4-w4m9","https://scholarworks.sjsu.edu/etd_theses/4805"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Customized production of synthetic DNA from oligonucleotides is in high demand. However, current technologies are costly and labor-intensive. A microfluidic technology can significantly decrease cost and labor. The purpose of this study was to develop a gene assembly protocol that was utilized on the Mondrian™ SP digital microfluidic device. The fragment of the human influenza virus hemagglutinin (HA) gene (339 bp) was assembled from 12 oligonucleotides by the Gibson assembly method and error corrected with CorrectASE™ enzyme twice. The samples were analyzed by Sanger sequencing to verify the final accuracy of the assembly. A complete automation of droplet generation and movement on digital microfluidic droplet technology was achieved in the study. The reactions were scaled down to 0.6-1.2 µL. Gibson assembly, PCR, and enzymatic error correction reactions were optimized and combined in a single protocol. The microfluidic assembly demonstrated approximately 3 errors/kb error frequency. Polymerase chain reaction supplemented with additional MgCl2, Phusion, and PEG 8000 provided amplification of the assembly and error correction products. The lowest error frequency of 0.3 errors/kb was achieved after one CorrectASE™ treatment. However, microfluidic error correction was not reliable due to CorrectASE™ interactions with the microfluidic surface, which need to be the subject of future work."]},{"key":"dc:title","label":"Title","values":["Development of DNA assembly and error correction protocols for a digital microfluidic device"]}]}],"canonical_facts":{"dc:contributor":["Melanie McNeil"],"dc:creator":["Khilko, Yuliya"],"dc:date.available":["2017-12-23T08:00:00Z"],"dc:date.created":["2017-01-01T08:00:00Z"],"dc:description.abstract":["Customized production of synthetic DNA from oligonucleotides is in high demand. However, current technologies are costly and labor-intensive. A microfluidic technology can significantly decrease cost and labor. The purpose of this study was to develop a gene assembly protocol that was utilized on the Mondrian™ SP digital microfluidic device. The fragment of the human influenza virus hemagglutinin (HA) gene (339 bp) was assembled from 12 oligonucleotides by the Gibson assembly method and error corrected with CorrectASE™ enzyme twice. The samples were analyzed by Sanger sequencing to verify the final accuracy of the assembly. A complete automation of droplet generation and movement on digital microfluidic droplet technology was achieved in the study. The reactions were scaled down to 0.6-1.2 µL. Gibson assembly, PCR, and enzymatic error correction reactions were optimized and combined in a single protocol. The microfluidic assembly demonstrated approximately 3 errors/kb error frequency. Polymerase chain reaction supplemented with additional MgCl2, Phusion, and PEG 8000 provided amplification of the assembly and error correction products. The lowest error frequency of 0.3 errors/kb was achieved after one CorrectASE™ treatment. However, microfluidic error correction was not reliable due to CorrectASE™ interactions with the microfluidic surface, which need to be the subject of future work."],"dc:identifier":["https://doi.org/10.31979/etd.uys4-w4m9","https://scholarworks.sjsu.edu/etd_theses/4805"],"dc:title":["Development of DNA assembly and error correction protocols for a digital microfluidic device"],"dc:type":["Thesis"],"thesis:degree_discipline":["Biomedical, Chemical & Materials Engineering"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-26T14:00:31Z"}