{"id":{"repo_id":"sjsu","oai_identifier":"oai:scholarworks.sjsu.edu:etd_theses-8442"},"canonical_url":"https://search.ndltd.org/etd/sjsu/oai:scholarworks.sjsu.edu:etd_theses-8442","repository":{"repo_id":"sjsu","name":"San Jose State University","base_url":"https://scholarworks.sjsu.edu/do/oai/"},"display":{"title":"Evaluation of the Fragility of East Bay Municipal Utility District (EBMUD) Mokelumne Aqueduct","abstract":"The East Bay Municipal Utility District provides water to the eastern region of the San Francisco Bay Area. Water is delivered through the Mokelumne Aqueduct, which consists of three large diameter steel pipelines. Approximately 15 miles of the aqueducts cross the fragile Sacramento-San Joaquin Delta. A stability analysis has been conducted to evaluate how resilient the elevated aqueduct is in the Delta. Subsidence in the Delta considerably reduces the lateral support of piles. Based on previous studies, and available survey and LiDAR data, the amount of subsidence in the Delta has been predicted over time. In addition, site-specific seismic studies have been considered in order to estimate strong ground motion parameters. A series of axial single pile analyses, lateral single pile analyses, and pile group analyses have been performed to quantify the impact of ground loss due to subsidence on pile capacities along the 15-mile alignment. Results were compared with both the maximum expected lateral load at the pile cap occurring due to seismic ground motion (base shear) and the lateral capacity at the 1-inch horizontal displacement of the pile cap (threshold). Analysis shows a significant reduction in the piles’ lateral and axial capacities, caused by lack of soil shear strength. The analytical studies are presented and discussed in order to develop retrofit alternatives.","abstract_html":"The East Bay Municipal Utility District provides water to the eastern region of the San Francisco Bay Area. Water is delivered through the Mokelumne Aqueduct, which consists of three large diameter steel pipelines. Approximately 15 miles of the aqueducts cross the fragile Sacramento-San Joaquin Delta. A stability analysis has been conducted to evaluate how resilient the elevated aqueduct is in the Delta. Subsidence in the Delta considerably reduces the lateral support of piles. Based on previous studies, and available survey and LiDAR data, the amount of subsidence in the Delta has been predicted over time. In addition, site-specific seismic studies have been considered in order to estimate strong ground motion parameters. A series of axial single pile analyses, lateral single pile analyses, and pile group analyses have been performed to quantify the impact of ground loss due to subsidence on pile capacities along the 15-mile alignment. Results were compared with both the maximum expected lateral load at the pile cap occurring due to seismic ground motion (base shear) and the lateral capacity at the 1-inch horizontal displacement of the pile cap (threshold). Analysis shows a significant reduction in the piles’ lateral and axial capacities, caused by lack of soil shear strength. The analytical studies are presented and discussed in order to develop retrofit alternatives.","abstract_has_math":false,"creators":["Chalian, Sara"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":null,"degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["Yogesh Prashar"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T14:00:39Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarworks.sjsu.edu/etd_theses/4895"],"render_values":[{"text":"https://scholarworks.sjsu.edu/etd_theses/4895","href":"https://scholarworks.sjsu.edu/etd_theses/4895","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.31979/etd.a7y5-fy24","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.31979/etd.a7y5-fy24","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Asjsu%3Aoai%3Ascholarworks.sjsu.edu%3Aetd_theses-8442","prefix":"oai_dc"},"source_record":{"url":"https://scholarworks.sjsu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarworks.sjsu.edu%3Aetd_theses-8442","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Yogesh Prashar"]},{"key":"dc:creator","label":"Author","values":["Chalian, Sara"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2018-06-29T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.31979/etd.a7y5-fy24","https://scholarworks.sjsu.edu/etd_theses/4895"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The East Bay Municipal Utility District provides water to the eastern region of the San Francisco Bay Area. Water is delivered through the Mokelumne Aqueduct, which consists of three large diameter steel pipelines. Approximately 15 miles of the aqueducts cross the fragile Sacramento-San Joaquin Delta. A stability analysis has been conducted to evaluate how resilient the elevated aqueduct is in the Delta. Subsidence in the Delta considerably reduces the lateral support of piles. Based on previous studies, and available survey and LiDAR data, the amount of subsidence in the Delta has been predicted over time. In addition, site-specific seismic studies have been considered in order to estimate strong ground motion parameters. A series of axial single pile analyses, lateral single pile analyses, and pile group analyses have been performed to quantify the impact of ground loss due to subsidence on pile capacities along the 15-mile alignment. Results were compared with both the maximum expected lateral load at the pile cap occurring due to seismic ground motion (base shear) and the lateral capacity at the 1-inch horizontal displacement of the pile cap (threshold). Analysis shows a significant reduction in the piles’ lateral and axial capacities, caused by lack of soil shear strength. The analytical studies are presented and discussed in order to develop retrofit alternatives."]},{"key":"dc:title","label":"Title","values":["Evaluation of the Fragility of East Bay Municipal Utility District (EBMUD) Mokelumne Aqueduct"]}]}],"canonical_facts":{"dc:contributor":["Yogesh Prashar"],"dc:creator":["Chalian, Sara"],"dc:date.created":["2018-06-29T07:00:00Z"],"dc:description.abstract":["The East Bay Municipal Utility District provides water to the eastern region of the San Francisco Bay Area. Water is delivered through the Mokelumne Aqueduct, which consists of three large diameter steel pipelines. Approximately 15 miles of the aqueducts cross the fragile Sacramento-San Joaquin Delta. A stability analysis has been conducted to evaluate how resilient the elevated aqueduct is in the Delta. Subsidence in the Delta considerably reduces the lateral support of piles. Based on previous studies, and available survey and LiDAR data, the amount of subsidence in the Delta has been predicted over time. In addition, site-specific seismic studies have been considered in order to estimate strong ground motion parameters. A series of axial single pile analyses, lateral single pile analyses, and pile group analyses have been performed to quantify the impact of ground loss due to subsidence on pile capacities along the 15-mile alignment. Results were compared with both the maximum expected lateral load at the pile cap occurring due to seismic ground motion (base shear) and the lateral capacity at the 1-inch horizontal displacement of the pile cap (threshold). Analysis shows a significant reduction in the piles’ lateral and axial capacities, caused by lack of soil shear strength. The analytical studies are presented and discussed in order to develop retrofit alternatives."],"dc:identifier":["https://doi.org/10.31979/etd.a7y5-fy24","https://scholarworks.sjsu.edu/etd_theses/4895"],"dc:title":["Evaluation of the Fragility of East Bay Municipal Utility District (EBMUD) Mokelumne Aqueduct"],"dc:type":["Thesis"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-26T14:00:39Z"}