{"id":{"repo_id":"sjsu","oai_identifier":"oai:scholarworks.sjsu.edu:etd_theses-8586"},"canonical_url":"https://search.ndltd.org/etd/sjsu/oai:scholarworks.sjsu.edu:etd_theses-8586","repository":{"repo_id":"sjsu","name":"San Jose State University","base_url":"https://scholarworks.sjsu.edu/do/oai/"},"display":{"title":"Determination of Demagnetizing Factors in Nanomagnets by First-Order Reversal Curves and Ferromagnetic Resonance","abstract":"Magnetic reversal in nickel nanowire arrays due to an axial, external magnetic field was studied through first-order reversal curve (FORC) measurement. A general function modeling the observed Preisach distribution was developed using the moving Preisach model. Fitting allowed determination of the sample's demagnetizing field at saturation and modeling magnetic reversal with respect to the internal magnetic field. Magnetization dynamics in the sample were studied through ferromagnetic resonance (FMR) measurement to aid in interpreting FORC fit results. Combining FORC and FMR results yielded the saturation magnetization and effective demagnetizing factors of the sample. Similar analysis was performed for a thin film sample, indicating an effective magnetizing interaction. The calculated axial demagnetizing factor of the array was significantly larger than the expected value for an isolated nanowire by the ellipsoid approximation. Therefore, this study demonstrates successful quantitative analysis of the demagnetizing interaction between nanowires in the array.","abstract_html":"Magnetic reversal in nickel nanowire arrays due to an axial, external magnetic field was studied through first-order reversal curve (FORC) measurement. A general function modeling the observed Preisach distribution was developed using the moving Preisach model. Fitting allowed determination of the sample&#x27;s demagnetizing field at saturation and modeling magnetic reversal with respect to the internal magnetic field. Magnetization dynamics in the sample were studied through ferromagnetic resonance (FMR) measurement to aid in interpreting FORC fit results. Combining FORC and FMR results yielded the saturation magnetization and effective demagnetizing factors of the sample. Similar analysis was performed for a thin film sample, indicating an effective magnetizing interaction. The calculated axial demagnetizing factor of the array was significantly larger than the expected value for an isolated nanowire by the ellipsoid approximation. Therefore, this study demonstrates successful quantitative analysis of the demagnetizing interaction between nanowires in the array.","abstract_has_math":false,"creators":["Muster, Karl Scott"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":null,"degree_discipline":"Physics and Astronomy","degree_department":null,"school":null,"contributors":["Ranko Heindl"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T14:00:53Z","subjects":["fmr","forc","magnetism","nanowire","reversal","vsm"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarworks.sjsu.edu/etd_theses/5039"],"render_values":[{"text":"https://scholarworks.sjsu.edu/etd_theses/5039","href":"https://scholarworks.sjsu.edu/etd_theses/5039","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.31979/etd.xxkb-zf6k","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.31979/etd.xxkb-zf6k","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Asjsu%3Aoai%3Ascholarworks.sjsu.edu%3Aetd_theses-8586","prefix":"oai_dc"},"source_record":{"url":"https://scholarworks.sjsu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarworks.sjsu.edu%3Aetd_theses-8586","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Ranko Heindl"]},{"key":"dc:creator","label":"Author","values":["Muster, Karl Scott"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2021-10-07T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2019-10-10T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics and Astronomy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["fmr","forc","magnetism","nanowire","reversal","vsm"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.31979/etd.xxkb-zf6k","https://scholarworks.sjsu.edu/etd_theses/5039"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Magnetic reversal in nickel nanowire arrays due to an axial, external magnetic field was studied through first-order reversal curve (FORC) measurement. A general function modeling the observed Preisach distribution was developed using the moving Preisach model. Fitting allowed determination of the sample's demagnetizing field at saturation and modeling magnetic reversal with respect to the internal magnetic field. Magnetization dynamics in the sample were studied through ferromagnetic resonance (FMR) measurement to aid in interpreting FORC fit results. Combining FORC and FMR results yielded the saturation magnetization and effective demagnetizing factors of the sample. Similar analysis was performed for a thin film sample, indicating an effective magnetizing interaction. The calculated axial demagnetizing factor of the array was significantly larger than the expected value for an isolated nanowire by the ellipsoid approximation. Therefore, this study demonstrates successful quantitative analysis of the demagnetizing interaction between nanowires in the array."]},{"key":"dc:title","label":"Title","values":["Determination of Demagnetizing Factors in Nanomagnets by First-Order Reversal Curves and Ferromagnetic Resonance"]}]}],"canonical_facts":{"dc:contributor":["Ranko Heindl"],"dc:creator":["Muster, Karl Scott"],"dc:date.available":["2021-10-07T07:00:00Z"],"dc:date.created":["2019-10-10T07:00:00Z"],"dc:description.abstract":["Magnetic reversal in nickel nanowire arrays due to an axial, external magnetic field was studied through first-order reversal curve (FORC) measurement. A general function modeling the observed Preisach distribution was developed using the moving Preisach model. Fitting allowed determination of the sample's demagnetizing field at saturation and modeling magnetic reversal with respect to the internal magnetic field. Magnetization dynamics in the sample were studied through ferromagnetic resonance (FMR) measurement to aid in interpreting FORC fit results. Combining FORC and FMR results yielded the saturation magnetization and effective demagnetizing factors of the sample. Similar analysis was performed for a thin film sample, indicating an effective magnetizing interaction. The calculated axial demagnetizing factor of the array was significantly larger than the expected value for an isolated nanowire by the ellipsoid approximation. Therefore, this study demonstrates successful quantitative analysis of the demagnetizing interaction between nanowires in the array."],"dc:identifier":["https://doi.org/10.31979/etd.xxkb-zf6k","https://scholarworks.sjsu.edu/etd_theses/5039"],"dc:subject":["fmr","forc","magnetism","nanowire","reversal","vsm"],"dc:title":["Determination of Demagnetizing Factors in Nanomagnets by First-Order Reversal Curves and Ferromagnetic Resonance"],"dc:type":["Thesis"],"thesis:degree_discipline":["Physics and Astronomy"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-26T14:00:53Z"}