{"id":{"repo_id":"sjsu","oai_identifier":"oai:scholarworks.sjsu.edu:etd_theses-8600"},"canonical_url":"https://search.ndltd.org/etd/sjsu/oai:scholarworks.sjsu.edu:etd_theses-8600","repository":{"repo_id":"sjsu","name":"San Jose State University","base_url":"https://scholarworks.sjsu.edu/do/oai/"},"display":{"title":"Time-Invariant Tensile Necking of Blood on an Electrowetting Digital Microfluidic Platform","abstract":"Recent developments in electrowetting-on-dielectric (EWOD) technology have expanded the possibilities for testing methods and investigation of blood. This work evaluated the development of necking geometry of whole blood and red blood cell (RBC) suspensions on a digital microfluidic (DMF) platform. This was achieved by applying tension to liquid droplet specimens on an EWOD-based device using applied electrowetting forces, thereby inducing necking. The deformation of 5 μL fluid specimens was recorded using neck radius and minimum neck width as two characteristic geometric parameters. Tensile tests were performed on phosphate-buffered saline (PBS), whole blood diluted in PBS, and RBCs suspended in PBS at hematocrit values of 10%. Although rheological measurements suggested higher stiffness of RBC suspensions when treated with neuraminidase, necking profiles were indistinguishable from those of untreated RBC suspensions. When tested at two different dilutions, whole blood diluted 1:20 and 1:10 in PBS exhibited distinct necking profiles. The necking development was observed to be time-invariant and insensitive to the large variability otherwise observed among distinct DMF chips and distinct locations on the chips.","abstract_html":"Recent developments in electrowetting-on-dielectric (EWOD) technology have expanded the possibilities for testing methods and investigation of blood. This work evaluated the development of necking geometry of whole blood and red blood cell (RBC) suspensions on a digital microfluidic (DMF) platform. This was achieved by applying tension to liquid droplet specimens on an EWOD-based device using applied electrowetting forces, thereby inducing necking. The deformation of 5 μL fluid specimens was recorded using neck radius and minimum neck width as two characteristic geometric parameters. Tensile tests were performed on phosphate-buffered saline (PBS), whole blood diluted in PBS, and RBCs suspended in PBS at hematocrit values of 10%. Although rheological measurements suggested higher stiffness of RBC suspensions when treated with neuraminidase, necking profiles were indistinguishable from those of untreated RBC suspensions. When tested at two different dilutions, whole blood diluted 1:20 and 1:10 in PBS exhibited distinct necking profiles. The necking development was observed to be time-invariant and insensitive to the large variability otherwise observed among distinct DMF chips and distinct locations on the chips.","abstract_has_math":false,"creators":["Young, Curtis"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":null,"degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Sang-Joon Lee"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T14:00:53Z","subjects":["Blood Rheology","Coagulation","Digital Microfluidics","Electrowetting","Liquid Necking","Microfluidic Rheometry"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarworks.sjsu.edu/etd_theses/5053"],"render_values":[{"text":"https://scholarworks.sjsu.edu/etd_theses/5053","href":"https://scholarworks.sjsu.edu/etd_theses/5053","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.31979/etd.rpfx-4uq3","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.31979/etd.rpfx-4uq3","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Asjsu%3Aoai%3Ascholarworks.sjsu.edu%3Aetd_theses-8600","prefix":"oai_dc"},"source_record":{"url":"https://scholarworks.sjsu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarworks.sjsu.edu%3Aetd_theses-8600","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Sang-Joon Lee"]},{"key":"dc:creator","label":"Author","values":["Young, Curtis"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2021-04-05T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2019-10-10T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Blood Rheology","Coagulation","Digital Microfluidics","Electrowetting","Liquid Necking","Microfluidic Rheometry"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.31979/etd.rpfx-4uq3","https://scholarworks.sjsu.edu/etd_theses/5053"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Recent developments in electrowetting-on-dielectric (EWOD) technology have expanded the possibilities for testing methods and investigation of blood. This work evaluated the development of necking geometry of whole blood and red blood cell (RBC) suspensions on a digital microfluidic (DMF) platform. This was achieved by applying tension to liquid droplet specimens on an EWOD-based device using applied electrowetting forces, thereby inducing necking. The deformation of 5 μL fluid specimens was recorded using neck radius and minimum neck width as two characteristic geometric parameters. Tensile tests were performed on phosphate-buffered saline (PBS), whole blood diluted in PBS, and RBCs suspended in PBS at hematocrit values of 10%. Although rheological measurements suggested higher stiffness of RBC suspensions when treated with neuraminidase, necking profiles were indistinguishable from those of untreated RBC suspensions. When tested at two different dilutions, whole blood diluted 1:20 and 1:10 in PBS exhibited distinct necking profiles. The necking development was observed to be time-invariant and insensitive to the large variability otherwise observed among distinct DMF chips and distinct locations on the chips."]},{"key":"dc:title","label":"Title","values":["Time-Invariant Tensile Necking of Blood on an Electrowetting Digital Microfluidic Platform"]}]}],"canonical_facts":{"dc:contributor":["Sang-Joon Lee"],"dc:creator":["Young, Curtis"],"dc:date.available":["2021-04-05T07:00:00Z"],"dc:date.created":["2019-10-10T07:00:00Z"],"dc:description.abstract":["Recent developments in electrowetting-on-dielectric (EWOD) technology have expanded the possibilities for testing methods and investigation of blood. This work evaluated the development of necking geometry of whole blood and red blood cell (RBC) suspensions on a digital microfluidic (DMF) platform. This was achieved by applying tension to liquid droplet specimens on an EWOD-based device using applied electrowetting forces, thereby inducing necking. The deformation of 5 μL fluid specimens was recorded using neck radius and minimum neck width as two characteristic geometric parameters. Tensile tests were performed on phosphate-buffered saline (PBS), whole blood diluted in PBS, and RBCs suspended in PBS at hematocrit values of 10%. Although rheological measurements suggested higher stiffness of RBC suspensions when treated with neuraminidase, necking profiles were indistinguishable from those of untreated RBC suspensions. When tested at two different dilutions, whole blood diluted 1:20 and 1:10 in PBS exhibited distinct necking profiles. The necking development was observed to be time-invariant and insensitive to the large variability otherwise observed among distinct DMF chips and distinct locations on the chips."],"dc:identifier":["https://doi.org/10.31979/etd.rpfx-4uq3","https://scholarworks.sjsu.edu/etd_theses/5053"],"dc:subject":["Blood Rheology","Coagulation","Digital Microfluidics","Electrowetting","Liquid Necking","Microfluidic Rheometry"],"dc:title":["Time-Invariant Tensile Necking of Blood on an Electrowetting Digital Microfluidic Platform"],"dc:type":["Thesis"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-26T14:00:53Z"}