{"id":{"repo_id":"sjsu","oai_identifier":"oai:scholarworks.sjsu.edu:etd_theses-8712"},"canonical_url":"https://search.ndltd.org/etd/sjsu/oai:scholarworks.sjsu.edu:etd_theses-8712","repository":{"repo_id":"sjsu","name":"San Jose State University","base_url":"https://scholarworks.sjsu.edu/do/oai/"},"display":{"title":"Methods for Improving an Electronic Nose System to Detect Urinary Tract Infection","abstract":"An electronic nose technology was developed that aimed at an in vitro classification of urinary samples infected with different strains of Escherichia coli to predict the causing agents of urinary tract infection. The predictive model was optimized by developing a culturing protocol to ensure consistent assay as well as utilizing a headspace GC/MS method to characterize ethanol content in the samples. By employing a robust artificial neural network, it was shown to be able to extract the unique patterns of VOCs of the samples and successfully differentiate between those classes. For datasets collected from multiple measurements, the prediction accuracy was improved by including training data from the appropriate first few measurement cycles, which were deemed quality data from a stability test with the GC/MS. Lastly, a passive cell separation technique called deterministic lateral displacement (DLD) was enhanced by applying gap size variation while keeping the row shift fraction unchanged. This novel approach, which increases separation resolution while maintaining the microsystem throughput, was found to be disjunctive from the conventional method for not being predictable by the standard critical size equation. Future research could explore the capability of the DLD system as a bacterial concentrator and the possibility of automation, which highlights its great potentials for incorporating into the e-nose system.","abstract_html":"An electronic nose technology was developed that aimed at an in vitro classification of urinary samples infected with different strains of Escherichia coli to predict the causing agents of urinary tract infection. The predictive model was optimized by developing a culturing protocol to ensure consistent assay as well as utilizing a headspace GC/MS method to characterize ethanol content in the samples. By employing a robust artificial neural network, it was shown to be able to extract the unique patterns of VOCs of the samples and successfully differentiate between those classes. For datasets collected from multiple measurements, the prediction accuracy was improved by including training data from the appropriate first few measurement cycles, which were deemed quality data from a stability test with the GC/MS. Lastly, a passive cell separation technique called deterministic lateral displacement (DLD) was enhanced by applying gap size variation while keeping the row shift fraction unchanged. This novel approach, which increases separation resolution while maintaining the microsystem throughput, was found to be disjunctive from the conventional method for not being predictable by the standard critical size equation. Future research could explore the capability of the DLD system as a bacterial concentrator and the possibility of automation, which highlights its great potentials for incorporating into the e-nose system.","abstract_has_math":false,"creators":["Than, Nam T"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":null,"degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Melinda Simon"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T14:01:02Z","subjects":["artificial neural network","COMSOL","deterministic lateral displacement","electronic nose","urinary tract infection","volatile organic compounds"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarworks.sjsu.edu/etd_theses/5165"],"render_values":[{"text":"https://scholarworks.sjsu.edu/etd_theses/5165","href":"https://scholarworks.sjsu.edu/etd_theses/5165","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.31979/etd.tdmg-9wgr","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.31979/etd.tdmg-9wgr","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Asjsu%3Aoai%3Ascholarworks.sjsu.edu%3Aetd_theses-8712","prefix":"oai_dc"},"source_record":{"url":"https://scholarworks.sjsu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarworks.sjsu.edu%3Aetd_theses-8712","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Melinda Simon"]},{"key":"dc:creator","label":"Author","values":["Than, Nam T"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2022-07-28T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2020-01-01T08:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis - Campus Access Only"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["artificial neural network","COMSOL","deterministic lateral displacement","electronic nose","urinary tract infection","volatile organic compounds"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.31979/etd.tdmg-9wgr","https://scholarworks.sjsu.edu/etd_theses/5165"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An electronic nose technology was developed that aimed at an in vitro classification of urinary samples infected with different strains of Escherichia coli to predict the causing agents of urinary tract infection. The predictive model was optimized by developing a culturing protocol to ensure consistent assay as well as utilizing a headspace GC/MS method to characterize ethanol content in the samples. By employing a robust artificial neural network, it was shown to be able to extract the unique patterns of VOCs of the samples and successfully differentiate between those classes. For datasets collected from multiple measurements, the prediction accuracy was improved by including training data from the appropriate first few measurement cycles, which were deemed quality data from a stability test with the GC/MS. Lastly, a passive cell separation technique called deterministic lateral displacement (DLD) was enhanced by applying gap size variation while keeping the row shift fraction unchanged. This novel approach, which increases separation resolution while maintaining the microsystem throughput, was found to be disjunctive from the conventional method for not being predictable by the standard critical size equation. Future research could explore the capability of the DLD system as a bacterial concentrator and the possibility of automation, which highlights its great potentials for incorporating into the e-nose system."]},{"key":"dc:title","label":"Title","values":["Methods for Improving an Electronic Nose System to Detect Urinary Tract Infection"]}]}],"canonical_facts":{"dc:contributor":["Melinda Simon"],"dc:creator":["Than, Nam T"],"dc:date.available":["2022-07-28T07:00:00Z"],"dc:date.created":["2020-01-01T08:00:00Z"],"dc:description.abstract":["An electronic nose technology was developed that aimed at an in vitro classification of urinary samples infected with different strains of Escherichia coli to predict the causing agents of urinary tract infection. The predictive model was optimized by developing a culturing protocol to ensure consistent assay as well as utilizing a headspace GC/MS method to characterize ethanol content in the samples. By employing a robust artificial neural network, it was shown to be able to extract the unique patterns of VOCs of the samples and successfully differentiate between those classes. For datasets collected from multiple measurements, the prediction accuracy was improved by including training data from the appropriate first few measurement cycles, which were deemed quality data from a stability test with the GC/MS. Lastly, a passive cell separation technique called deterministic lateral displacement (DLD) was enhanced by applying gap size variation while keeping the row shift fraction unchanged. This novel approach, which increases separation resolution while maintaining the microsystem throughput, was found to be disjunctive from the conventional method for not being predictable by the standard critical size equation. Future research could explore the capability of the DLD system as a bacterial concentrator and the possibility of automation, which highlights its great potentials for incorporating into the e-nose system."],"dc:identifier":["https://doi.org/10.31979/etd.tdmg-9wgr","https://scholarworks.sjsu.edu/etd_theses/5165"],"dc:subject":["artificial neural network","COMSOL","deterministic lateral displacement","electronic nose","urinary tract infection","volatile organic compounds"],"dc:title":["Methods for Improving an Electronic Nose System to Detect Urinary Tract Infection"],"dc:type":["Thesis - Campus Access Only"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-26T14:01:02Z"}