{"id":{"repo_id":"sjsu","oai_identifier":"oai:scholarworks.sjsu.edu:etd_theses-9220"},"canonical_url":"https://search.ndltd.org/etd/sjsu/oai:scholarworks.sjsu.edu:etd_theses-9220","repository":{"repo_id":"sjsu","name":"San Jose State University","base_url":"https://scholarworks.sjsu.edu/do/oai/"},"display":{"title":"Fluid-Structure Interaction Comsol Model for Unsteady Flow Through a 3D Bi-Leaflet Mechanical Heart Valve","abstract":"In this study, we developed a 3D Fluid-Structure Interaction (FSI) model using COMSOL© to analyze the unsteady flow through a bi-leaflet mechanical heart valve. The model incorporates sufficient complexity to test various factors, such as leaflet angle rotation, material selection for rigid components, fluid properties, and different simulation modes. Simultaneously, the model maintains a simplified structure and is developed using a single software platform, facilitating ease of modification and expansion by other researchers or developers. The mechanical heart valve (MHV) design was created using St. Jude’s geometric parameters as a reference. The input and output pressure waveforms are derived from interpolated ventricular and aortic pressures and were used as simulation inputs. The resulting velocity, vorticity, shear, and pressure profiles were analyzed and compared to previously published laboratory results and available clinical data from All of US Research databases for validation. The output velocity and shear stress profiles aligned strongly with published laboratory results, highlighting the model’s reliability and potential for practical use. The findings contribute to the ongoing development of computational cardiovascular simulations, bridging the gap between experimental and numerical analyses in MHV designs.","abstract_html":"In this study, we developed a 3D Fluid-Structure Interaction (FSI) model using COMSOL© to analyze the unsteady flow through a bi-leaflet mechanical heart valve. The model incorporates sufficient complexity to test various factors, such as leaflet angle rotation, material selection for rigid components, fluid properties, and different simulation modes. Simultaneously, the model maintains a simplified structure and is developed using a single software platform, facilitating ease of modification and expansion by other researchers or developers. The mechanical heart valve (MHV) design was created using St. Jude’s geometric parameters as a reference. The input and output pressure waveforms are derived from interpolated ventricular and aortic pressures and were used as simulation inputs. The resulting velocity, vorticity, shear, and pressure profiles were analyzed and compared to previously published laboratory results and available clinical data from All of US Research databases for validation. The output velocity and shear stress profiles aligned strongly with published laboratory results, highlighting the model’s reliability and potential for practical use. The findings contribute to the ongoing development of computational cardiovascular simulations, bridging the gap between experimental and numerical analyses in MHV designs.","abstract_has_math":false,"creators":["Zaky, Aya"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":null,"degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Alessandro Bellofiore; Lin Jiang; Yue Luo"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T14:03:51Z","subjects":["2D;3D;bi-leaflet MHV;CFD;FSI;numerical model"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarworks.sjsu.edu/etd_theses/5673"],"render_values":[{"text":"https://scholarworks.sjsu.edu/etd_theses/5673","href":"https://scholarworks.sjsu.edu/etd_theses/5673","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.31979/etd.ghg3-zf8g","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.31979/etd.ghg3-zf8g","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Asjsu%3Aoai%3Ascholarworks.sjsu.edu%3Aetd_theses-9220","prefix":"oai_dc"},"source_record":{"url":"https://scholarworks.sjsu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarworks.sjsu.edu%3Aetd_theses-9220","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Alessandro Bellofiore; Lin Jiang; Yue Luo"]},{"key":"dc:creator","label":"Author","values":["Zaky, Aya"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2025-07-24T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["2D;3D;bi-leaflet MHV;CFD;FSI;numerical model"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.31979/etd.ghg3-zf8g","https://scholarworks.sjsu.edu/etd_theses/5673"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In this study, we developed a 3D Fluid-Structure Interaction (FSI) model using COMSOL© to analyze the unsteady flow through a bi-leaflet mechanical heart valve. The model incorporates sufficient complexity to test various factors, such as leaflet angle rotation, material selection for rigid components, fluid properties, and different simulation modes. Simultaneously, the model maintains a simplified structure and is developed using a single software platform, facilitating ease of modification and expansion by other researchers or developers. The mechanical heart valve (MHV) design was created using St. Jude’s geometric parameters as a reference. The input and output pressure waveforms are derived from interpolated ventricular and aortic pressures and were used as simulation inputs. The resulting velocity, vorticity, shear, and pressure profiles were analyzed and compared to previously published laboratory results and available clinical data from All of US Research databases for validation. The output velocity and shear stress profiles aligned strongly with published laboratory results, highlighting the model’s reliability and potential for practical use. The findings contribute to the ongoing development of computational cardiovascular simulations, bridging the gap between experimental and numerical analyses in MHV designs."]},{"key":"dc:title","label":"Title","values":["Fluid-Structure Interaction Comsol Model for Unsteady Flow Through a 3D Bi-Leaflet Mechanical Heart Valve"]}]}],"canonical_facts":{"dc:contributor":["Alessandro Bellofiore; Lin Jiang; Yue Luo"],"dc:creator":["Zaky, Aya"],"dc:date.created":["2025-07-24T07:00:00Z"],"dc:description.abstract":["In this study, we developed a 3D Fluid-Structure Interaction (FSI) model using COMSOL© to analyze the unsteady flow through a bi-leaflet mechanical heart valve. The model incorporates sufficient complexity to test various factors, such as leaflet angle rotation, material selection for rigid components, fluid properties, and different simulation modes. Simultaneously, the model maintains a simplified structure and is developed using a single software platform, facilitating ease of modification and expansion by other researchers or developers. The mechanical heart valve (MHV) design was created using St. Jude’s geometric parameters as a reference. The input and output pressure waveforms are derived from interpolated ventricular and aortic pressures and were used as simulation inputs. The resulting velocity, vorticity, shear, and pressure profiles were analyzed and compared to previously published laboratory results and available clinical data from All of US Research databases for validation. The output velocity and shear stress profiles aligned strongly with published laboratory results, highlighting the model’s reliability and potential for practical use. The findings contribute to the ongoing development of computational cardiovascular simulations, bridging the gap between experimental and numerical analyses in MHV designs."],"dc:identifier":["https://doi.org/10.31979/etd.ghg3-zf8g","https://scholarworks.sjsu.edu/etd_theses/5673"],"dc:subject":["2D;3D;bi-leaflet MHV;CFD;FSI;numerical model"],"dc:title":["Fluid-Structure Interaction Comsol Model for Unsteady Flow Through a 3D Bi-Leaflet Mechanical Heart Valve"],"dc:type":["Thesis"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-26T14:03:51Z"}