{"id":{"repo_id":"soton","oai_identifier":"oai:eprints.soton.ac.uk:414081"},"canonical_url":"https://search.ndltd.org/etd/soton/oai:eprints.soton.ac.uk:414081","repository":{"repo_id":"soton","name":"University of Southampton","base_url":"https://eprints.soton.ac.uk/cgi/oai2"},"display":{"title":"Model investigation into the hydraulic performance of mattress protected slopes of low head hydraulic structures","abstract":"The aim of this study was to provide some information about the<br/>hydraulic performance of mattresses protecting slopes of low head<br/>hydraulic structures. The flow resistance as well as stability of<br/>slope were investigated.<br/><br/>The experimental programme was conducted in the Chilworth<br/>Hydraulics Laboratory, Department of Civil Engineering. Two<br/>models were constructed and tested. The inpermeable model (first)<br/>had a slope of 1:7 (V;H) with mattress dimensions of 320x350mm<br/>and a height of 40mm. The permeable model (second) was built with<br/>the same slope except that the mattresses were protecting a sand<br/>core.<br/><br/>The flow resistance of the mattresses was studied which included<br/>Manning's roughness coefficient, Chezy's resistance factor and<br/>Darcy-Weisbach friction factor. Velocity distribution above the<br/>mattresses was evaluated and found well describing the flow.<br/>The stability of the mattresses and their ability to resist<br/>failure when exposed to higher discharges were also examined and<br/>found stable under the discharges tried.<br/><br/>Detailed measurement of pressures were conducted in the permeable<br/>model in order to study their effects on the stability of the<br/>mattresses; such as; pressure distribution above the mattresses,<br/>uplift pressures and seepage forces. Shear stresses due to<br/>seepage forces were found very small and could be neglected.<br/>Comparison with the results of smooth board simulating a<br/>reinforced concrete structure, favours the mattresses as a means<br/>to control erosion and dissipate energy efficiently.<br/><br/>Measures were suggested in terms of installation to reduce the<br/>drag and uplift forces. A design procedure for a slope protected<br/>by mattresses was set up and followed by a numerical example<br/>implementing the results obtained in this study.<br/>—<br/>","abstract_html":"The aim of this study was to provide some information about the&lt;br/&gt;hydraulic performance of mattresses protecting slopes of low head&lt;br/&gt;hydraulic structures. The flow resistance as well as stability of&lt;br/&gt;slope were investigated.&lt;br/&gt;&lt;br/&gt;The experimental programme was conducted in the Chilworth&lt;br/&gt;Hydraulics Laboratory, Department of Civil Engineering. Two&lt;br/&gt;models were constructed and tested. The inpermeable model (first)&lt;br/&gt;had a slope of 1:7 (V;H) with mattress dimensions of 320x350mm&lt;br/&gt;and a height of 40mm. The permeable model (second) was built with&lt;br/&gt;the same slope except that the mattresses were protecting a sand&lt;br/&gt;core.&lt;br/&gt;&lt;br/&gt;The flow resistance of the mattresses was studied which included&lt;br/&gt;Manning&#x27;s roughness coefficient, Chezy&#x27;s resistance factor and&lt;br/&gt;Darcy-Weisbach friction factor. Velocity distribution above the&lt;br/&gt;mattresses was evaluated and found well describing the flow.&lt;br/&gt;The stability of the mattresses and their ability to resist&lt;br/&gt;failure when exposed to higher discharges were also examined and&lt;br/&gt;found stable under the discharges tried.&lt;br/&gt;&lt;br/&gt;Detailed measurement of pressures were conducted in the permeable&lt;br/&gt;model in order to study their effects on the stability of the&lt;br/&gt;mattresses; such as; pressure distribution above the mattresses,&lt;br/&gt;uplift pressures and seepage forces. Shear stresses due to&lt;br/&gt;seepage forces were found very small and could be neglected.&lt;br/&gt;Comparison with the results of smooth board simulating a&lt;br/&gt;reinforced concrete structure, favours the mattresses as a means&lt;br/&gt;to control erosion and dissipate energy efficiently.&lt;br/&gt;&lt;br/&gt;Measures were suggested in terms of installation to reduce the&lt;br/&gt;drag and uplift forces. A design procedure for a slope protected&lt;br/&gt;by mattresses was set up and followed by a numerical example&lt;br/&gt;implementing the results obtained in this study.&lt;br/&gt;—&lt;br/&gt;","abstract_has_math":false,"creators":["Tahir, Taha"],"institution":"University of Southampton","degree_name":"Ph.D.","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Tosswell, Paul"],"committee_chairs":[],"committee_members":[],"year":1993,"date_issued":"1993-01","date_published":"1993-01","updated_at":"2026-11-19T09:33:13Z","subjects":[],"languages":["English","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://eprints.soton.ac.uk/id/eprint/414081/1/93031284.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://eprints.soton.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.soton.ac.uk%3A414081","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Tosswell, Paul"]},{"key":"dc:creator","label":"Author","values":["Tahir, Taha"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1993-01-01"]},{"key":"dc:date.issued","label":"Date","values":["1993-01"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Southampton"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Civil Engineering & the Environment (pre 2011 reorg)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Southampton"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://eprints.soton.ac.uk/id/eprint/414081/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://eprints.soton.ac.uk/id/eprint/414081/1/93031284.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The aim of this study was to provide some information about the<br/>hydraulic performance of mattresses protecting slopes of low head<br/>hydraulic structures. The flow resistance as well as stability of<br/>slope were investigated.<br/><br/>The experimental programme was conducted in the Chilworth<br/>Hydraulics Laboratory, Department of Civil Engineering. Two<br/>models were constructed and tested. The inpermeable model (first)<br/>had a slope of 1:7 (V;H) with mattress dimensions of 320x350mm<br/>and a height of 40mm. The permeable model (second) was built with<br/>the same slope except that the mattresses were protecting a sand<br/>core.<br/><br/>The flow resistance of the mattresses was studied which included<br/>Manning's roughness coefficient, Chezy's resistance factor and<br/>Darcy-Weisbach friction factor. Velocity distribution above the<br/>mattresses was evaluated and found well describing the flow.<br/>The stability of the mattresses and their ability to resist<br/>failure when exposed to higher discharges were also examined and<br/>found stable under the discharges tried.<br/><br/>Detailed measurement of pressures were conducted in the permeable<br/>model in order to study their effects on the stability of the<br/>mattresses; such as; pressure distribution above the mattresses,<br/>uplift pressures and seepage forces. Shear stresses due to<br/>seepage forces were found very small and could be neglected.<br/>Comparison with the results of smooth board simulating a<br/>reinforced concrete structure, favours the mattresses as a means<br/>to control erosion and dissipate energy efficiently.<br/><br/>Measures were suggested in terms of installation to reduce the<br/>drag and uplift forces. A design procedure for a slope protected<br/>by mattresses was set up and followed by a numerical example<br/>implementing the results obtained in this study.<br/>—<br/>"]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Model investigation into the hydraulic performance of mattress protected slopes of low head hydraulic structures"]}]}],"canonical_facts":{"dc:contributor.advisor":["Tosswell, Paul"],"dc:creator":["Tahir, Taha"],"dc:date":["1993-01-01"],"dc:date.issued":["1993-01"],"dc:description.abstract":["The aim of this study was to provide some information about the<br/>hydraulic performance of mattresses protecting slopes of low head<br/>hydraulic structures. The flow resistance as well as stability of<br/>slope were investigated.<br/><br/>The experimental programme was conducted in the Chilworth<br/>Hydraulics Laboratory, Department of Civil Engineering. Two<br/>models were constructed and tested. The inpermeable model (first)<br/>had a slope of 1:7 (V;H) with mattress dimensions of 320x350mm<br/>and a height of 40mm. The permeable model (second) was built with<br/>the same slope except that the mattresses were protecting a sand<br/>core.<br/><br/>The flow resistance of the mattresses was studied which included<br/>Manning's roughness coefficient, Chezy's resistance factor and<br/>Darcy-Weisbach friction factor. Velocity distribution above the<br/>mattresses was evaluated and found well describing the flow.<br/>The stability of the mattresses and their ability to resist<br/>failure when exposed to higher discharges were also examined and<br/>found stable under the discharges tried.<br/><br/>Detailed measurement of pressures were conducted in the permeable<br/>model in order to study their effects on the stability of the<br/>mattresses; such as; pressure distribution above the mattresses,<br/>uplift pressures and seepage forces. Shear stresses due to<br/>seepage forces were found very small and could be neglected.<br/>Comparison with the results of smooth board simulating a<br/>reinforced concrete structure, favours the mattresses as a means<br/>to control erosion and dissipate energy efficiently.<br/><br/>Measures were suggested in terms of installation to reduce the<br/>drag and uplift forces. A design procedure for a slope protected<br/>by mattresses was set up and followed by a numerical example<br/>implementing the results obtained in this study.<br/>—<br/>"],"dc:format":["text"],"dc:identifier.uri":["https://eprints.soton.ac.uk/id/eprint/414081/1/93031284.pdf"],"dc:language":["English"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Southampton"],"dc:publisher.department":["Civil Engineering & the Environment (pre 2011 reorg)"],"dc:publisher.institution":["University of Southampton"],"dc:relation.isreferencedby":["https://eprints.soton.ac.uk/id/eprint/414081/"],"dcterms:accessrights":["public"],"dc:title":["Model investigation into the hydraulic performance of mattress protected slopes of low head hydraulic structures"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D."]},"updated_at":"2026-11-19T09:33:13Z"}