{"id":{"repo_id":"soton","oai_identifier":"oai:eprints.soton.ac.uk:461332"},"canonical_url":"https://search.ndltd.org/etd/soton/oai:eprints.soton.ac.uk:461332","repository":{"repo_id":"soton","name":"University of Southampton","base_url":"https://eprints.soton.ac.uk/cgi/oai2"},"display":{"title":"Active noise control in ducts using adaptive digital filters","abstract":"<p>The propagation of sound in a duct can be actively controlled by introducing a secondary source driven to cancel t he original sound wave produced by a primary source. In this study we compare for the first time in the same conditions three adaptive time domain algorithms currently used for the active control of noise in ducts : the LMS (Least Mean Square) algorithm, the LMS algorithm with feedback cancellation and the infinite impulse response LMS algorithm. Firstly we establish the theoretical basis necessary to calculate the optimal single channel controller. Secondly we study each algorithm through a practical realisation and through computer simulation using an appropriate electro-acoustic model of the real The infinite impulse response algorithm is found to be the most efficient one. Moreover we demonstrated that the imperfect frequency response of the transducers (microphone and loudspeakers) is responsible for most of the limitation of the active noise control system. experiment.</p>","abstract_html":"&lt;p&gt;The propagation of sound in a duct can be actively controlled by introducing a secondary source driven to cancel t he original sound wave produced by a primary source. In this study we compare for the first time in the same conditions three adaptive time domain algorithms currently used for the active control of noise in ducts : the LMS (Least Mean Square) algorithm, the LMS algorithm with feedback cancellation and the infinite impulse response LMS algorithm. Firstly we establish the theoretical basis necessary to calculate the optimal single channel controller. Secondly we study each algorithm through a practical realisation and through computer simulation using an appropriate electro-acoustic model of the real The infinite impulse response algorithm is found to be the most efficient one. Moreover we demonstrated that the imperfect frequency response of the transducers (microphone and loudspeakers) is responsible for most of the limitation of the active noise control system. experiment.&lt;/p&gt;","abstract_has_math":false,"creators":["Billet, Laurent Ludovic Jerome"],"institution":"University of Southampton","degree_name":"Ph.D.","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1992,"date_issued":"1992","date_published":"1992","updated_at":"2026-11-19T09:36:05Z","subjects":[],"languages":["English","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://eprints.soton.ac.uk/id/eprint/461332/1/351159.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://eprints.soton.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.soton.ac.uk%3A461332","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Billet, Laurent Ludovic Jerome"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1992"]},{"key":"dc:date.issued","label":"Date","values":["1992"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Southampton"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Inst. Sound & Vibration Research (pre 2018 reorg)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Southampton"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://eprints.soton.ac.uk/id/eprint/461332/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://eprints.soton.ac.uk/id/eprint/461332/1/351159.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>The propagation of sound in a duct can be actively controlled by introducing a secondary source driven to cancel t he original sound wave produced by a primary source. In this study we compare for the first time in the same conditions three adaptive time domain algorithms currently used for the active control of noise in ducts : the LMS (Least Mean Square) algorithm, the LMS algorithm with feedback cancellation and the infinite impulse response LMS algorithm. Firstly we establish the theoretical basis necessary to calculate the optimal single channel controller. Secondly we study each algorithm through a practical realisation and through computer simulation using an appropriate electro-acoustic model of the real The infinite impulse response algorithm is found to be the most efficient one. Moreover we demonstrated that the imperfect frequency response of the transducers (microphone and loudspeakers) is responsible for most of the limitation of the active noise control system. experiment.</p>"]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Active noise control in ducts using adaptive digital filters"]}]}],"canonical_facts":{"dc:creator":["Billet, Laurent Ludovic Jerome"],"dc:date":["1992"],"dc:date.issued":["1992"],"dc:description.abstract":["<p>The propagation of sound in a duct can be actively controlled by introducing a secondary source driven to cancel t he original sound wave produced by a primary source. In this study we compare for the first time in the same conditions three adaptive time domain algorithms currently used for the active control of noise in ducts : the LMS (Least Mean Square) algorithm, the LMS algorithm with feedback cancellation and the infinite impulse response LMS algorithm. Firstly we establish the theoretical basis necessary to calculate the optimal single channel controller. Secondly we study each algorithm through a practical realisation and through computer simulation using an appropriate electro-acoustic model of the real The infinite impulse response algorithm is found to be the most efficient one. Moreover we demonstrated that the imperfect frequency response of the transducers (microphone and loudspeakers) is responsible for most of the limitation of the active noise control system. experiment.</p>"],"dc:format":["text"],"dc:identifier.uri":["https://eprints.soton.ac.uk/id/eprint/461332/1/351159.pdf"],"dc:language":["English"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Southampton"],"dc:publisher.department":["Inst. Sound & Vibration Research (pre 2018 reorg)"],"dc:publisher.institution":["University of Southampton"],"dc:relation.isreferencedby":["https://eprints.soton.ac.uk/id/eprint/461332/"],"dcterms:accessrights":["public"],"dc:title":["Active noise control in ducts using adaptive digital filters"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D."]},"updated_at":"2026-11-19T09:36:05Z"}