{"id":{"repo_id":"soton","oai_identifier":"oai:eprints.soton.ac.uk:464304"},"canonical_url":"https://search.ndltd.org/etd/soton/oai:eprints.soton.ac.uk:464304","repository":{"repo_id":"soton","name":"University of Southampton","base_url":"https://eprints.soton.ac.uk/cgi/oai2"},"display":{"title":"Damage structures and fault evolution around strike-slip faults","abstract":"<p>Damage zones around strike-slip faults show a variety of fracture patterns related to stress concentration and accommodation of displacement. Damage zone structures can be classified into three main groups according to their location along a strike-slip fault - tip zone, wall zone and linking zone structures. Tip damage zones can be sub-divided according to fault tip modes such as along-strike tips (Mode II) and up- and down-dip tips (Mode III). Wall zone damage structures patterns that reflect the propagation of the fault and slip-induced deformation (kinematic damage). Linking zone damage structures are developed between adjacent tip zones of two parallel or sub-parallel faults and vary between dilational and contractual oversteps. Lens-shaped structures evolve from old fault segment tips.</p><p>Analysis of maximum displacement (<i>d<sub>max</sub></i>) - length (<i>L</i>) relationships for fault populations shows that strike-slip fault systems evolve from isolated faults through segmented faults to interacting faults. Most geologic faults have a much higher ratio of <i>d<sub>max</sub>/L</i> than for single slip events (<i>u/L</i>).</p><p>Reactivation with the opposite sense of slip modifies the pattern of damage structures around strike-slip faults. Evidence for reverse reactivation includes two groups of tip cracks with different orientations and very low or negative displacements at fault tips.</p><p>Fractal analysis shows self-similarity over 6 orders of magnitude. Fractal dimensions for damage zones are higher than for the main fault traces. Strike-slip faults share many similar geometric features over a wide scale range.</p>","abstract_html":"&lt;p&gt;Damage zones around strike-slip faults show a variety of fracture patterns related to stress concentration and accommodation of displacement. Damage zone structures can be classified into three main groups according to their location along a strike-slip fault - tip zone, wall zone and linking zone structures. Tip damage zones can be sub-divided according to fault tip modes such as along-strike tips (Mode II) and up- and down-dip tips (Mode III). Wall zone damage structures patterns that reflect the propagation of the fault and slip-induced deformation (kinematic damage). Linking zone damage structures are developed between adjacent tip zones of two parallel or sub-parallel faults and vary between dilational and contractual oversteps. Lens-shaped structures evolve from old fault segment tips.&lt;/p&gt;&lt;p&gt;Analysis of maximum displacement (&lt;i&gt;d&lt;sub&gt;max&lt;/sub&gt;&lt;/i&gt;) - length (&lt;i&gt;L&lt;/i&gt;) relationships for fault populations shows that strike-slip fault systems evolve from isolated faults through segmented faults to interacting faults. Most geologic faults have a much higher ratio of &lt;i&gt;d&lt;sub&gt;max&lt;/sub&gt;/L&lt;/i&gt; than for single slip events (&lt;i&gt;u/L&lt;/i&gt;).&lt;/p&gt;&lt;p&gt;Reactivation with the opposite sense of slip modifies the pattern of damage structures around strike-slip faults. Evidence for reverse reactivation includes two groups of tip cracks with different orientations and very low or negative displacements at fault tips.&lt;/p&gt;&lt;p&gt;Fractal analysis shows self-similarity over 6 orders of magnitude. Fractal dimensions for damage zones are higher than for the main fault traces. Strike-slip faults share many similar geometric features over a wide scale range.&lt;/p&gt;","abstract_has_math":false,"creators":["Kim, Young-Seog"],"institution":"University of Southampton","degree_name":"Ph.D.","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2000,"date_issued":"2000","date_published":"2000","updated_at":"2026-11-19T09:36:49Z","subjects":[],"languages":["English","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://eprints.soton.ac.uk/id/eprint/464304/1/775035.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://eprints.soton.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.soton.ac.uk%3A464304","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Kim, Young-Seog"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2000"]},{"key":"dc:date.issued","label":"Date","values":["2000"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Southampton"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Ocean and Earth Science (pre 2011 reorg)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Southampton"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://eprints.soton.ac.uk/id/eprint/464304/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://eprints.soton.ac.uk/id/eprint/464304/1/775035.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>Damage zones around strike-slip faults show a variety of fracture patterns related to stress concentration and accommodation of displacement. Damage zone structures can be classified into three main groups according to their location along a strike-slip fault - tip zone, wall zone and linking zone structures. Tip damage zones can be sub-divided according to fault tip modes such as along-strike tips (Mode II) and up- and down-dip tips (Mode III). Wall zone damage structures patterns that reflect the propagation of the fault and slip-induced deformation (kinematic damage). Linking zone damage structures are developed between adjacent tip zones of two parallel or sub-parallel faults and vary between dilational and contractual oversteps. Lens-shaped structures evolve from old fault segment tips.</p><p>Analysis of maximum displacement (<i>d<sub>max</sub></i>) - length (<i>L</i>) relationships for fault populations shows that strike-slip fault systems evolve from isolated faults through segmented faults to interacting faults. Most geologic faults have a much higher ratio of <i>d<sub>max</sub>/L</i> than for single slip events (<i>u/L</i>).</p><p>Reactivation with the opposite sense of slip modifies the pattern of damage structures around strike-slip faults. Evidence for reverse reactivation includes two groups of tip cracks with different orientations and very low or negative displacements at fault tips.</p><p>Fractal analysis shows self-similarity over 6 orders of magnitude. Fractal dimensions for damage zones are higher than for the main fault traces. Strike-slip faults share many similar geometric features over a wide scale range.</p>"]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Damage structures and fault evolution around strike-slip faults"]}]}],"canonical_facts":{"dc:creator":["Kim, Young-Seog"],"dc:date":["2000"],"dc:date.issued":["2000"],"dc:description.abstract":["<p>Damage zones around strike-slip faults show a variety of fracture patterns related to stress concentration and accommodation of displacement. Damage zone structures can be classified into three main groups according to their location along a strike-slip fault - tip zone, wall zone and linking zone structures. Tip damage zones can be sub-divided according to fault tip modes such as along-strike tips (Mode II) and up- and down-dip tips (Mode III). Wall zone damage structures patterns that reflect the propagation of the fault and slip-induced deformation (kinematic damage). Linking zone damage structures are developed between adjacent tip zones of two parallel or sub-parallel faults and vary between dilational and contractual oversteps. Lens-shaped structures evolve from old fault segment tips.</p><p>Analysis of maximum displacement (<i>d<sub>max</sub></i>) - length (<i>L</i>) relationships for fault populations shows that strike-slip fault systems evolve from isolated faults through segmented faults to interacting faults. Most geologic faults have a much higher ratio of <i>d<sub>max</sub>/L</i> than for single slip events (<i>u/L</i>).</p><p>Reactivation with the opposite sense of slip modifies the pattern of damage structures around strike-slip faults. Evidence for reverse reactivation includes two groups of tip cracks with different orientations and very low or negative displacements at fault tips.</p><p>Fractal analysis shows self-similarity over 6 orders of magnitude. Fractal dimensions for damage zones are higher than for the main fault traces. Strike-slip faults share many similar geometric features over a wide scale range.</p>"],"dc:format":["text"],"dc:identifier.uri":["https://eprints.soton.ac.uk/id/eprint/464304/1/775035.pdf"],"dc:language":["English"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Southampton"],"dc:publisher.department":["Ocean and Earth Science (pre 2011 reorg)"],"dc:publisher.institution":["University of Southampton"],"dc:relation.isreferencedby":["https://eprints.soton.ac.uk/id/eprint/464304/"],"dcterms:accessrights":["public"],"dc:title":["Damage structures and fault evolution around strike-slip faults"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D."]},"updated_at":"2026-11-19T09:36:49Z"}