{"id":{"repo_id":"soton","oai_identifier":"oai:eprints.soton.ac.uk:464321"},"canonical_url":"https://search.ndltd.org/etd/soton/oai:eprints.soton.ac.uk:464321","repository":{"repo_id":"soton","name":"University of Southampton","base_url":"https://eprints.soton.ac.uk/cgi/oai2"},"display":{"title":"Towards time resolution in EXAFS of fuel cell electrocatalysts","abstract":"<p>Mechanistic and kinetic investigations of fuel cell reactions in real time has not been possible with the conventional XAS technique due to the protracted data collection time. Synchrotron instrumentation improvements have reduced the data collection time to minutes with QuEXAFS and installation of a bent crystal monochromator allows the entire data range to be collected simultaneously with EDE.</p><p><i>In situ</i> X-ray absorption spectra of Pt/C electrodes were collected by conventional XAS, QuEXAFS, and EDE techniques, and are compared; data collection times were 40 mins, 60 s, and 1.9 s respectively. Conventional and QuEXAFS spectra were of similar data quality whereas EDE data exhibited a significant increase in the noise and a decrease in resolution. A shortened data range from k = 17 Å<sup>-1</sup> for conventional data to 13 Å<sup>-1</sup> for QuEXAFS, and 9 Å<sup>-1</sup> for EDE causes an artificial decrease in the calculated coordination numbers. It was concluded that QuEXAFS and EDE would not lead to accurate calculated structural parameters.</p><p>Further modifications to the beamline improved the signal to noise ratio and resolution of QuEXAFS and EDE spectra. QuEXAFS therefore replaced conventional XAS since the data was comparable in quality and took a third of the time to collect. The data range of EDE spectra was extended to k = 14 Å<sup>-1</sup> and a new PC system allowed for faster and structural parameters. Subsequently, it was concluded that future developments are required on the beamline to increase the signal to noise ratio of the data collected and increase the energy range available. The signal to noise ratio may be improved with a higher energy beam and the use of more advanced detectors. These developments are in progress. At present, it cannot be seen how to increase the energy range, other than with the use of a longer crystal monochromator.</p>","abstract_html":"&lt;p&gt;Mechanistic and kinetic investigations of fuel cell reactions in real time has not been possible with the conventional XAS technique due to the protracted data collection time. Synchrotron instrumentation improvements have reduced the data collection time to minutes with QuEXAFS and installation of a bent crystal monochromator allows the entire data range to be collected simultaneously with EDE.&lt;/p&gt;&lt;p&gt;&lt;i&gt;In situ&lt;/i&gt; X-ray absorption spectra of Pt/C electrodes were collected by conventional XAS, QuEXAFS, and EDE techniques, and are compared; data collection times were 40 mins, 60 s, and 1.9 s respectively. Conventional and QuEXAFS spectra were of similar data quality whereas EDE data exhibited a significant increase in the noise and a decrease in resolution. A shortened data range from k = 17 Å&lt;sup&gt;-1&lt;/sup&gt; for conventional data to 13 Å&lt;sup&gt;-1&lt;/sup&gt; for QuEXAFS, and 9 Å&lt;sup&gt;-1&lt;/sup&gt; for EDE causes an artificial decrease in the calculated coordination numbers. It was concluded that QuEXAFS and EDE would not lead to accurate calculated structural parameters.&lt;/p&gt;&lt;p&gt;Further modifications to the beamline improved the signal to noise ratio and resolution of QuEXAFS and EDE spectra. QuEXAFS therefore replaced conventional XAS since the data was comparable in quality and took a third of the time to collect. The data range of EDE spectra was extended to k = 14 Å&lt;sup&gt;-1&lt;/sup&gt; and a new PC system allowed for faster and structural parameters. Subsequently, it was concluded that future developments are required on the beamline to increase the signal to noise ratio of the data collected and increase the energy range available. The signal to noise ratio may be improved with a higher energy beam and the use of more advanced detectors. These developments are in progress. At present, it cannot be seen how to increase the energy range, other than with the use of a longer crystal monochromator.&lt;/p&gt;","abstract_has_math":false,"creators":["Mathew, Rebecca Jane"],"institution":"University of Southampton","degree_name":"Ph.D.","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2001,"date_issued":"2001","date_published":"2001","updated_at":"2026-11-19T09:36:49Z","subjects":[],"languages":["English","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://eprints.soton.ac.uk/id/eprint/464321/1/776503.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://eprints.soton.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.soton.ac.uk%3A464321","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Mathew, Rebecca Jane"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2001"]},{"key":"dc:date.issued","label":"Date","values":["2001"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Southampton"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Chemistry (pre 2011 reorg)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Southampton"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://eprints.soton.ac.uk/id/eprint/464321/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://eprints.soton.ac.uk/id/eprint/464321/1/776503.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>Mechanistic and kinetic investigations of fuel cell reactions in real time has not been possible with the conventional XAS technique due to the protracted data collection time. Synchrotron instrumentation improvements have reduced the data collection time to minutes with QuEXAFS and installation of a bent crystal monochromator allows the entire data range to be collected simultaneously with EDE.</p><p><i>In situ</i> X-ray absorption spectra of Pt/C electrodes were collected by conventional XAS, QuEXAFS, and EDE techniques, and are compared; data collection times were 40 mins, 60 s, and 1.9 s respectively. Conventional and QuEXAFS spectra were of similar data quality whereas EDE data exhibited a significant increase in the noise and a decrease in resolution. A shortened data range from k = 17 Å<sup>-1</sup> for conventional data to 13 Å<sup>-1</sup> for QuEXAFS, and 9 Å<sup>-1</sup> for EDE causes an artificial decrease in the calculated coordination numbers. It was concluded that QuEXAFS and EDE would not lead to accurate calculated structural parameters.</p><p>Further modifications to the beamline improved the signal to noise ratio and resolution of QuEXAFS and EDE spectra. QuEXAFS therefore replaced conventional XAS since the data was comparable in quality and took a third of the time to collect. The data range of EDE spectra was extended to k = 14 Å<sup>-1</sup> and a new PC system allowed for faster and structural parameters. Subsequently, it was concluded that future developments are required on the beamline to increase the signal to noise ratio of the data collected and increase the energy range available. The signal to noise ratio may be improved with a higher energy beam and the use of more advanced detectors. These developments are in progress. At present, it cannot be seen how to increase the energy range, other than with the use of a longer crystal monochromator.</p>"]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Towards time resolution in EXAFS of fuel cell electrocatalysts"]}]}],"canonical_facts":{"dc:creator":["Mathew, Rebecca Jane"],"dc:date":["2001"],"dc:date.issued":["2001"],"dc:description.abstract":["<p>Mechanistic and kinetic investigations of fuel cell reactions in real time has not been possible with the conventional XAS technique due to the protracted data collection time. Synchrotron instrumentation improvements have reduced the data collection time to minutes with QuEXAFS and installation of a bent crystal monochromator allows the entire data range to be collected simultaneously with EDE.</p><p><i>In situ</i> X-ray absorption spectra of Pt/C electrodes were collected by conventional XAS, QuEXAFS, and EDE techniques, and are compared; data collection times were 40 mins, 60 s, and 1.9 s respectively. Conventional and QuEXAFS spectra were of similar data quality whereas EDE data exhibited a significant increase in the noise and a decrease in resolution. A shortened data range from k = 17 Å<sup>-1</sup> for conventional data to 13 Å<sup>-1</sup> for QuEXAFS, and 9 Å<sup>-1</sup> for EDE causes an artificial decrease in the calculated coordination numbers. It was concluded that QuEXAFS and EDE would not lead to accurate calculated structural parameters.</p><p>Further modifications to the beamline improved the signal to noise ratio and resolution of QuEXAFS and EDE spectra. QuEXAFS therefore replaced conventional XAS since the data was comparable in quality and took a third of the time to collect. The data range of EDE spectra was extended to k = 14 Å<sup>-1</sup> and a new PC system allowed for faster and structural parameters. Subsequently, it was concluded that future developments are required on the beamline to increase the signal to noise ratio of the data collected and increase the energy range available. The signal to noise ratio may be improved with a higher energy beam and the use of more advanced detectors. These developments are in progress. At present, it cannot be seen how to increase the energy range, other than with the use of a longer crystal monochromator.</p>"],"dc:format":["text"],"dc:identifier.uri":["https://eprints.soton.ac.uk/id/eprint/464321/1/776503.pdf"],"dc:language":["English"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Southampton"],"dc:publisher.department":["Chemistry (pre 2011 reorg)"],"dc:publisher.institution":["University of Southampton"],"dc:relation.isreferencedby":["https://eprints.soton.ac.uk/id/eprint/464321/"],"dcterms:accessrights":["public"],"dc:title":["Towards time resolution in EXAFS of fuel cell electrocatalysts"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D."]},"updated_at":"2026-11-19T09:36:49Z"}