{"id":{"repo_id":"soton","oai_identifier":"oai:eprints.soton.ac.uk:464790"},"canonical_url":"https://search.ndltd.org/etd/soton/oai:eprints.soton.ac.uk:464790","repository":{"repo_id":"soton","name":"University of Southampton","base_url":"https://eprints.soton.ac.uk/cgi/oai2"},"display":{"title":"The use of the electrochemical quartz crystal microbalance for the analysis of poly(aniline) composite films","abstract":"<p>The Electrochemical Quartz Crystal Microbalance has been largely used for the analysis of conducting polymers. Many groups quantify the mass increase or decrease on the surface of the quartz crystal directly from the changes in the resonant frequency of the crystal by applying the Sauerbrey equation. However this correlation can be used only if the material coated on the crystal is a thin, smooth and rigid layer. We treat the quartz crystal and the coating as a single resonator which can be represented as an equivalent electrical circuit (Butterworth-Van Dyke). The variation in the coating mass is compared to the changes in the inductance and the viscoelasticity is related to the resistance of the electrical circuit. Only in the case when the resistance is maintained close to zero throughout an experiment can the Sauerbrey equation be applied. The components of the equivalent electrical circuit are obtained by using the transfer function method, which is faster than an impedance measurement. The non-validity of the Sauerbrey equation is demonstrated for the hydration of a hydrophilic polymer film. The polymer swells considerably in water creating a very soft hydrated film. The use of mathematical simulations was then necessary in order to calculate of the rate of hydration, i.e. changes in the thickness of the film.</p> <p>We have applied the transfer function method on the Electrochemical Quartz Crystal Microbalance to study the electrodeposition and the redox switching of conducting polymers. The poly(aniline) films were electropolymerised in the presence of poly(vinylsulfonate) or poly(styrenesulfonate) counterions. The polymer films presented different morphology depending on the poly(anion) used during polymerisation. The polymer film which obeyed the Sauerbrey approximation was used in studies of ionic movement during voltammetric cycles in different inorganic acids.</p>","abstract_html":"&lt;p&gt;The Electrochemical Quartz Crystal Microbalance has been largely used for the analysis of conducting polymers. Many groups quantify the mass increase or decrease on the surface of the quartz crystal directly from the changes in the resonant frequency of the crystal by applying the Sauerbrey equation. However this correlation can be used only if the material coated on the crystal is a thin, smooth and rigid layer. We treat the quartz crystal and the coating as a single resonator which can be represented as an equivalent electrical circuit (Butterworth-Van Dyke). The variation in the coating mass is compared to the changes in the inductance and the viscoelasticity is related to the resistance of the electrical circuit. Only in the case when the resistance is maintained close to zero throughout an experiment can the Sauerbrey equation be applied. The components of the equivalent electrical circuit are obtained by using the transfer function method, which is faster than an impedance measurement. The non-validity of the Sauerbrey equation is demonstrated for the hydration of a hydrophilic polymer film. The polymer swells considerably in water creating a very soft hydrated film. The use of mathematical simulations was then necessary in order to calculate of the rate of hydration, i.e. changes in the thickness of the film.&lt;/p&gt; &lt;p&gt;We have applied the transfer function method on the Electrochemical Quartz Crystal Microbalance to study the electrodeposition and the redox switching of conducting polymers. The poly(aniline) films were electropolymerised in the presence of poly(vinylsulfonate) or poly(styrenesulfonate) counterions. The polymer films presented different morphology depending on the poly(anion) used during polymerisation. The polymer film which obeyed the Sauerbrey approximation was used in studies of ionic movement during voltammetric cycles in different inorganic acids.&lt;/p&gt;","abstract_has_math":false,"creators":["Pitta, Luciana Sampaio"],"institution":"University of Southampton","degree_name":"Ph.D.","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2002,"date_issued":"2002","date_published":"2002","updated_at":"2026-11-19T09:37:06Z","subjects":[],"languages":["English","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://eprints.soton.ac.uk/id/eprint/464790/1/874682.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://eprints.soton.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.soton.ac.uk%3A464790","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Pitta, Luciana Sampaio"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2002"]},{"key":"dc:date.issued","label":"Date","values":["2002"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Southampton"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Chemistry (pre 2011 reorg)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Southampton"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://eprints.soton.ac.uk/id/eprint/464790/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://eprints.soton.ac.uk/id/eprint/464790/1/874682.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>The Electrochemical Quartz Crystal Microbalance has been largely used for the analysis of conducting polymers. Many groups quantify the mass increase or decrease on the surface of the quartz crystal directly from the changes in the resonant frequency of the crystal by applying the Sauerbrey equation. However this correlation can be used only if the material coated on the crystal is a thin, smooth and rigid layer. We treat the quartz crystal and the coating as a single resonator which can be represented as an equivalent electrical circuit (Butterworth-Van Dyke). The variation in the coating mass is compared to the changes in the inductance and the viscoelasticity is related to the resistance of the electrical circuit. Only in the case when the resistance is maintained close to zero throughout an experiment can the Sauerbrey equation be applied. The components of the equivalent electrical circuit are obtained by using the transfer function method, which is faster than an impedance measurement. The non-validity of the Sauerbrey equation is demonstrated for the hydration of a hydrophilic polymer film. The polymer swells considerably in water creating a very soft hydrated film. The use of mathematical simulations was then necessary in order to calculate of the rate of hydration, i.e. changes in the thickness of the film.</p> <p>We have applied the transfer function method on the Electrochemical Quartz Crystal Microbalance to study the electrodeposition and the redox switching of conducting polymers. The poly(aniline) films were electropolymerised in the presence of poly(vinylsulfonate) or poly(styrenesulfonate) counterions. The polymer films presented different morphology depending on the poly(anion) used during polymerisation. The polymer film which obeyed the Sauerbrey approximation was used in studies of ionic movement during voltammetric cycles in different inorganic acids.</p>"]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["The use of the electrochemical quartz crystal microbalance for the analysis of poly(aniline) composite films"]}]}],"canonical_facts":{"dc:creator":["Pitta, Luciana Sampaio"],"dc:date":["2002"],"dc:date.issued":["2002"],"dc:description.abstract":["<p>The Electrochemical Quartz Crystal Microbalance has been largely used for the analysis of conducting polymers. Many groups quantify the mass increase or decrease on the surface of the quartz crystal directly from the changes in the resonant frequency of the crystal by applying the Sauerbrey equation. However this correlation can be used only if the material coated on the crystal is a thin, smooth and rigid layer. We treat the quartz crystal and the coating as a single resonator which can be represented as an equivalent electrical circuit (Butterworth-Van Dyke). The variation in the coating mass is compared to the changes in the inductance and the viscoelasticity is related to the resistance of the electrical circuit. Only in the case when the resistance is maintained close to zero throughout an experiment can the Sauerbrey equation be applied. The components of the equivalent electrical circuit are obtained by using the transfer function method, which is faster than an impedance measurement. The non-validity of the Sauerbrey equation is demonstrated for the hydration of a hydrophilic polymer film. The polymer swells considerably in water creating a very soft hydrated film. The use of mathematical simulations was then necessary in order to calculate of the rate of hydration, i.e. changes in the thickness of the film.</p> <p>We have applied the transfer function method on the Electrochemical Quartz Crystal Microbalance to study the electrodeposition and the redox switching of conducting polymers. The poly(aniline) films were electropolymerised in the presence of poly(vinylsulfonate) or poly(styrenesulfonate) counterions. The polymer films presented different morphology depending on the poly(anion) used during polymerisation. The polymer film which obeyed the Sauerbrey approximation was used in studies of ionic movement during voltammetric cycles in different inorganic acids.</p>"],"dc:format":["text"],"dc:identifier.uri":["https://eprints.soton.ac.uk/id/eprint/464790/1/874682.pdf"],"dc:language":["English"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Southampton"],"dc:publisher.department":["Chemistry (pre 2011 reorg)"],"dc:publisher.institution":["University of Southampton"],"dc:relation.isreferencedby":["https://eprints.soton.ac.uk/id/eprint/464790/"],"dcterms:accessrights":["public"],"dc:title":["The use of the electrochemical quartz crystal microbalance for the analysis of poly(aniline) composite films"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D."]},"updated_at":"2026-11-19T09:37:06Z"}