{"id":{"repo_id":"soton","oai_identifier":"oai:eprints.soton.ac.uk:465620"},"canonical_url":"https://search.ndltd.org/etd/soton/oai:eprints.soton.ac.uk:465620","repository":{"repo_id":"soton","name":"University of Southampton","base_url":"https://eprints.soton.ac.uk/cgi/oai2"},"display":{"title":"Quench propagation in conduction cooled HTS pancake coils","abstract":"<p><span style='letter-spacing:-.05pt'>The formation and propagation of normal zones in a conduction cooled (BiPb)2223 Ag </span>alloy sheathed pancake coil has been investigated both experimentally and through simulation. To provide stable operating conditions for the coils a conduction cooling <span style='letter-spacing:-.15pt'>system, incorporating a single stage cryocooler, and current leads were designed and </span><span style='letter-spacing:-.1pt'>manufactured. The apparatus was tested up to a maximum operating current of 300A at </span><span style='letter-spacing:-.2pt'>which only a 0.7K drift in the coldhead temperature was observed. A minimum operating </span>temperature at the coil boundaries of 35K was achieved.</p> <p><span style='letter-spacing:-.2pt'>Highly instrumented pancake coils were wound with a (BiPb)2223 tape conductor. The </span><span style='letter-spacing:-.15pt'>current-voltage characteristics were measured and the response to a steady overcurrent observed. The quench energy was measured as a function of operating temperature by applying transient disturbances of varying sizes to the coil. A similar dependence of the </span><span style='letter-spacing:-.2pt'>quench energy on operating temperature was obtained from a simplified finite element </span>model.</p> <p><span style='letter-spacing:-.2pt'>A method of determining the temperature profile of a minimum propagating zone was </span><span style='letter-spacing:-.15pt'>proposed. The size and shape of the MPZ was measured as a function of operating </span><span style='letter-spacing:-.2pt'>temperature. It was observed that the shape of the temperature profiles was significantly </span><span style='letter-spacing:-.05pt'>affected by the operating temperature. The normal zone propagation velocity was </span>determined as a function of operating temperature by examining the propagating <span style='letter-spacing:-.2pt'>temperature profiles. The results obtained will be of use to the magnet designer when </span><span style='letter-spacing:-.15pt'>determining the stability of coils at various operating temperature and when designing </span>protection systems for HTS magnets.</p>","abstract_html":"&lt;p&gt;&lt;span style=&#x27;letter-spacing:-.05pt&#x27;&gt;The formation and propagation of normal zones in a conduction cooled (BiPb)2223 Ag &lt;/span&gt;alloy sheathed pancake coil has been investigated both experimentally and through simulation. To provide stable operating conditions for the coils a conduction cooling &lt;span style=&#x27;letter-spacing:-.15pt&#x27;&gt;system, incorporating a single stage cryocooler, and current leads were designed and &lt;/span&gt;&lt;span style=&#x27;letter-spacing:-.1pt&#x27;&gt;manufactured. The apparatus was tested up to a maximum operating current of 300A at &lt;/span&gt;&lt;span style=&#x27;letter-spacing:-.2pt&#x27;&gt;which only a 0.7K drift in the coldhead temperature was observed. A minimum operating &lt;/span&gt;temperature at the coil boundaries of 35K was achieved.&lt;/p&gt; &lt;p&gt;&lt;span style=&#x27;letter-spacing:-.2pt&#x27;&gt;Highly instrumented pancake coils were wound with a (BiPb)2223 tape conductor. The &lt;/span&gt;&lt;span style=&#x27;letter-spacing:-.15pt&#x27;&gt;current-voltage characteristics were measured and the response to a steady overcurrent observed. The quench energy was measured as a function of operating temperature by applying transient disturbances of varying sizes to the coil. A similar dependence of the &lt;/span&gt;&lt;span style=&#x27;letter-spacing:-.2pt&#x27;&gt;quench energy on operating temperature was obtained from a simplified finite element &lt;/span&gt;model.&lt;/p&gt; &lt;p&gt;&lt;span style=&#x27;letter-spacing:-.2pt&#x27;&gt;A method of determining the temperature profile of a minimum propagating zone was &lt;/span&gt;&lt;span style=&#x27;letter-spacing:-.15pt&#x27;&gt;proposed. The size and shape of the MPZ was measured as a function of operating &lt;/span&gt;&lt;span style=&#x27;letter-spacing:-.2pt&#x27;&gt;temperature. It was observed that the shape of the temperature profiles was significantly &lt;/span&gt;&lt;span style=&#x27;letter-spacing:-.05pt&#x27;&gt;affected by the operating temperature. The normal zone propagation velocity was &lt;/span&gt;determined as a function of operating temperature by examining the propagating &lt;span style=&#x27;letter-spacing:-.2pt&#x27;&gt;temperature profiles. The results obtained will be of use to the magnet designer when &lt;/span&gt;&lt;span style=&#x27;letter-spacing:-.15pt&#x27;&gt;determining the stability of coils at various operating temperature and when designing &lt;/span&gt;protection systems for HTS magnets.&lt;/p&gt;","abstract_has_math":false,"creators":["Johnstone, Adam Paul"],"institution":"University of Southampton","degree_name":"Ph.D.","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005","date_published":"2005","updated_at":"2026-11-19T09:52:25Z","subjects":[],"languages":["English","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://eprints.soton.ac.uk/id/eprint/465620/1/981925.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://eprints.soton.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.soton.ac.uk%3A465620","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Johnstone, Adam Paul"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2005"]},{"key":"dc:date.issued","label":"Date","values":["2005"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Southampton"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Engineering Sciences (pre 2011 reorg)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Southampton"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://eprints.soton.ac.uk/id/eprint/465620/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://eprints.soton.ac.uk/id/eprint/465620/1/981925.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p><span style='letter-spacing:-.05pt'>The formation and propagation of normal zones in a conduction cooled (BiPb)2223 Ag </span>alloy sheathed pancake coil has been investigated both experimentally and through simulation. To provide stable operating conditions for the coils a conduction cooling <span style='letter-spacing:-.15pt'>system, incorporating a single stage cryocooler, and current leads were designed and </span><span style='letter-spacing:-.1pt'>manufactured. The apparatus was tested up to a maximum operating current of 300A at </span><span style='letter-spacing:-.2pt'>which only a 0.7K drift in the coldhead temperature was observed. A minimum operating </span>temperature at the coil boundaries of 35K was achieved.</p> <p><span style='letter-spacing:-.2pt'>Highly instrumented pancake coils were wound with a (BiPb)2223 tape conductor. The </span><span style='letter-spacing:-.15pt'>current-voltage characteristics were measured and the response to a steady overcurrent observed. The quench energy was measured as a function of operating temperature by applying transient disturbances of varying sizes to the coil. A similar dependence of the </span><span style='letter-spacing:-.2pt'>quench energy on operating temperature was obtained from a simplified finite element </span>model.</p> <p><span style='letter-spacing:-.2pt'>A method of determining the temperature profile of a minimum propagating zone was </span><span style='letter-spacing:-.15pt'>proposed. The size and shape of the MPZ was measured as a function of operating </span><span style='letter-spacing:-.2pt'>temperature. It was observed that the shape of the temperature profiles was significantly </span><span style='letter-spacing:-.05pt'>affected by the operating temperature. The normal zone propagation velocity was </span>determined as a function of operating temperature by examining the propagating <span style='letter-spacing:-.2pt'>temperature profiles. The results obtained will be of use to the magnet designer when </span><span style='letter-spacing:-.15pt'>determining the stability of coils at various operating temperature and when designing </span>protection systems for HTS magnets.</p>"]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Quench propagation in conduction cooled HTS pancake coils"]}]}],"canonical_facts":{"dc:creator":["Johnstone, Adam Paul"],"dc:date":["2005"],"dc:date.issued":["2005"],"dc:description.abstract":["<p><span style='letter-spacing:-.05pt'>The formation and propagation of normal zones in a conduction cooled (BiPb)2223 Ag </span>alloy sheathed pancake coil has been investigated both experimentally and through simulation. To provide stable operating conditions for the coils a conduction cooling <span style='letter-spacing:-.15pt'>system, incorporating a single stage cryocooler, and current leads were designed and </span><span style='letter-spacing:-.1pt'>manufactured. The apparatus was tested up to a maximum operating current of 300A at </span><span style='letter-spacing:-.2pt'>which only a 0.7K drift in the coldhead temperature was observed. A minimum operating </span>temperature at the coil boundaries of 35K was achieved.</p> <p><span style='letter-spacing:-.2pt'>Highly instrumented pancake coils were wound with a (BiPb)2223 tape conductor. The </span><span style='letter-spacing:-.15pt'>current-voltage characteristics were measured and the response to a steady overcurrent observed. The quench energy was measured as a function of operating temperature by applying transient disturbances of varying sizes to the coil. A similar dependence of the </span><span style='letter-spacing:-.2pt'>quench energy on operating temperature was obtained from a simplified finite element </span>model.</p> <p><span style='letter-spacing:-.2pt'>A method of determining the temperature profile of a minimum propagating zone was </span><span style='letter-spacing:-.15pt'>proposed. The size and shape of the MPZ was measured as a function of operating </span><span style='letter-spacing:-.2pt'>temperature. It was observed that the shape of the temperature profiles was significantly </span><span style='letter-spacing:-.05pt'>affected by the operating temperature. The normal zone propagation velocity was </span>determined as a function of operating temperature by examining the propagating <span style='letter-spacing:-.2pt'>temperature profiles. The results obtained will be of use to the magnet designer when </span><span style='letter-spacing:-.15pt'>determining the stability of coils at various operating temperature and when designing </span>protection systems for HTS magnets.</p>"],"dc:format":["text"],"dc:identifier.uri":["https://eprints.soton.ac.uk/id/eprint/465620/1/981925.pdf"],"dc:language":["English"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Southampton"],"dc:publisher.department":["Engineering Sciences (pre 2011 reorg)"],"dc:publisher.institution":["University of Southampton"],"dc:relation.isreferencedby":["https://eprints.soton.ac.uk/id/eprint/465620/"],"dcterms:accessrights":["public"],"dc:title":["Quench propagation in conduction cooled HTS pancake coils"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D."]},"updated_at":"2026-11-19T09:52:25Z"}