{"id":{"repo_id":"soton","oai_identifier":"oai:eprints.soton.ac.uk:467186"},"canonical_url":"https://search.ndltd.org/etd/soton/oai:eprints.soton.ac.uk:467186","repository":{"repo_id":"soton","name":"University of Southampton","base_url":"https://eprints.soton.ac.uk/cgi/oai2"},"display":{"title":"The production of polymer fibres with high performance and FT-Raman spectroscopy at 1.3µm","abstract":"<p>The work described in this thesis involved the role of molten metal baths in the quench cooling of polyethylene in the production of polymer Abres with high performance. A melt-spinning rig was designed and constructed. Chapter 2 describes how polymer fibres were produced from the melt by spinning fibres through a reservoir of molten melt which was held at temperatures near the melting point of the polymer. Polyethylene fibres with a tensile modulus of the order of 25 GPa and tensile strength approaching 1 GPa were produced by a process of melt spinning followed by cold drawing to a draw ratio of 15. <br/></p><p>Raman spectroscopy is an invaluable analytical tool used in a multitude of applications. The ease and versatility of the technique provides a simple method for identification and studying crystallinity of specimens. The fbremost choice of laser source for FT-Raman has been the continuous wave Nd<sup>3+</sup>: YAG solid state laser operating at 1.064 µm. Chapter 4 investigates the possibility of using the 1.319 µm lasing emission from the Nd<sup>3+</sup>:YAG laser as an alternate source. The sensitivity of the source is determined, applications are illustrated and the limitations commented upon.</p>","abstract_html":"&lt;p&gt;The work described in this thesis involved the role of molten metal baths in the quench cooling of polyethylene in the production of polymer Abres with high performance. A melt-spinning rig was designed and constructed. Chapter 2 describes how polymer fibres were produced from the melt by spinning fibres through a reservoir of molten melt which was held at temperatures near the melting point of the polymer. Polyethylene fibres with a tensile modulus of the order of 25 GPa and tensile strength approaching 1 GPa were produced by a process of melt spinning followed by cold drawing to a draw ratio of 15. &lt;br/&gt;&lt;/p&gt;&lt;p&gt;Raman spectroscopy is an invaluable analytical tool used in a multitude of applications. The ease and versatility of the technique provides a simple method for identification and studying crystallinity of specimens. The fbremost choice of laser source for FT-Raman has been the continuous wave Nd&lt;sup&gt;3+&lt;/sup&gt;: YAG solid state laser operating at 1.064 µm. Chapter 4 investigates the possibility of using the 1.319 µm lasing emission from the Nd&lt;sup&gt;3+&lt;/sup&gt;:YAG laser as an alternate source. The sensitivity of the source is determined, applications are illustrated and the limitations commented upon.&lt;/p&gt;","abstract_has_math":false,"creators":["Murphy, Colm D"],"institution":"University of Southampton","degree_name":"Ph.D.","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2002,"date_issued":"2002","date_published":"2002","updated_at":"2026-11-19T09:53:40Z","subjects":[],"languages":["English","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://eprints.soton.ac.uk/id/eprint/467186/1/842500.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://eprints.soton.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.soton.ac.uk%3A467186","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Murphy, Colm D"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2002"]},{"key":"dc:date.issued","label":"Date","values":["2002"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Southampton"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Chemistry (pre 2011 reorg)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Southampton"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://eprints.soton.ac.uk/id/eprint/467186/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://eprints.soton.ac.uk/id/eprint/467186/1/842500.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>The work described in this thesis involved the role of molten metal baths in the quench cooling of polyethylene in the production of polymer Abres with high performance. A melt-spinning rig was designed and constructed. Chapter 2 describes how polymer fibres were produced from the melt by spinning fibres through a reservoir of molten melt which was held at temperatures near the melting point of the polymer. Polyethylene fibres with a tensile modulus of the order of 25 GPa and tensile strength approaching 1 GPa were produced by a process of melt spinning followed by cold drawing to a draw ratio of 15. <br/></p><p>Raman spectroscopy is an invaluable analytical tool used in a multitude of applications. The ease and versatility of the technique provides a simple method for identification and studying crystallinity of specimens. The fbremost choice of laser source for FT-Raman has been the continuous wave Nd<sup>3+</sup>: YAG solid state laser operating at 1.064 µm. Chapter 4 investigates the possibility of using the 1.319 µm lasing emission from the Nd<sup>3+</sup>:YAG laser as an alternate source. The sensitivity of the source is determined, applications are illustrated and the limitations commented upon.</p>"]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["The production of polymer fibres with high performance and FT-Raman spectroscopy at 1.3µm"]}]}],"canonical_facts":{"dc:creator":["Murphy, Colm D"],"dc:date":["2002"],"dc:date.issued":["2002"],"dc:description.abstract":["<p>The work described in this thesis involved the role of molten metal baths in the quench cooling of polyethylene in the production of polymer Abres with high performance. A melt-spinning rig was designed and constructed. Chapter 2 describes how polymer fibres were produced from the melt by spinning fibres through a reservoir of molten melt which was held at temperatures near the melting point of the polymer. Polyethylene fibres with a tensile modulus of the order of 25 GPa and tensile strength approaching 1 GPa were produced by a process of melt spinning followed by cold drawing to a draw ratio of 15. <br/></p><p>Raman spectroscopy is an invaluable analytical tool used in a multitude of applications. The ease and versatility of the technique provides a simple method for identification and studying crystallinity of specimens. The fbremost choice of laser source for FT-Raman has been the continuous wave Nd<sup>3+</sup>: YAG solid state laser operating at 1.064 µm. Chapter 4 investigates the possibility of using the 1.319 µm lasing emission from the Nd<sup>3+</sup>:YAG laser as an alternate source. The sensitivity of the source is determined, applications are illustrated and the limitations commented upon.</p>"],"dc:format":["text"],"dc:identifier.uri":["https://eprints.soton.ac.uk/id/eprint/467186/1/842500.pdf"],"dc:language":["English"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Southampton"],"dc:publisher.department":["Chemistry (pre 2011 reorg)"],"dc:publisher.institution":["University of Southampton"],"dc:relation.isreferencedby":["https://eprints.soton.ac.uk/id/eprint/467186/"],"dcterms:accessrights":["public"],"dc:title":["The production of polymer fibres with high performance and FT-Raman spectroscopy at 1.3µm"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D."]},"updated_at":"2026-11-19T09:53:40Z"}