{"id":{"repo_id":"soton","oai_identifier":"oai:eprints.soton.ac.uk:51152"},"canonical_url":"https://search.ndltd.org/etd/soton/oai:eprints.soton.ac.uk:51152","repository":{"repo_id":"soton","name":"University of Southampton","base_url":"https://eprints.soton.ac.uk/cgi/oai2"},"display":{"title":"Acoustic models of consonant recognition in cochlear implant users","abstract":"Normal-hearing adults have no difficulty in recognising consonants accurately, even in moderately adverse listening conditions. By contrast, users of multichannel cochlear implants have difficulty with the accurate perception of consonants, even in good listening conditions. Cochlear implant users are known to show systematic deficits in recognition of consonant features, with perception of the place feature, which relies on spectral information, being worst. These deficits may be attributed both to signal distortions introduced by the processing of the implants and to other factors, in particular the spectrotemporal distortions which occur at the interface between electrode array and auditory nervous system, including cross-channel interaction. The objective of the work reported here was to attempt to partial out the relative contribution of these different factors to consonant recognition. This was achieved by comparing cochlear implant users’ perceptual errors, analysed in terms of information transmission, with errors made by normal-hearing subjects listening to acoustic models of implant processing, in various conditions. Two initial experiments were undertaken to develop and refine an acoustic model of the Nucleus 24 cochlear implant. Findings from these two experiments informed the design of the main acoustic model experiment, which was undertaken in parallel with a further experiment involving users of the Nucleus 24 device. In both experiments, subjects listened to nonsense syllables with and without the addition of stationary background noise, in three different configurations of implant processing parameters. Additionally, in the acoustic model experiment, a simulation of cross-channel spread of excitation, or “channel interaction”, was varied. Results showed that acoustic model experiments were predictive of the pattern of consonant feature transmission in cochlear implant users with better baseline consonant recognition scores. Deficits in consonant recognition in this subgroup could be explained by the loss of phonemically relevant acoustic information in speech due to the nature of cochlear implant processing, while channel interaction appeared to play a smaller role in accounting for problems in consonant recognition. The work also evaluated the effect of changes in channel number and stimulation rate and failed to find any changes in consonant recognition as these parameters were varied. The lack of a stimulation rate effect was consistent with acoustic measurements of the temporal modulation transfer function of the processor, which showed almost no change across stimulation rates.","abstract_html":"Normal-hearing adults have no difficulty in recognising consonants accurately, even in moderately adverse listening conditions. By contrast, users of multichannel cochlear implants have difficulty with the accurate perception of consonants, even in good listening conditions. Cochlear implant users are known to show systematic deficits in recognition of consonant features, with perception of the place feature, which relies on spectral information, being worst. These deficits may be attributed both to signal distortions introduced by the processing of the implants and to other factors, in particular the spectrotemporal distortions which occur at the interface between electrode array and auditory nervous system, including cross-channel interaction. The objective of the work reported here was to attempt to partial out the relative contribution of these different factors to consonant recognition. This was achieved by comparing cochlear implant users’ perceptual errors, analysed in terms of information transmission, with errors made by normal-hearing subjects listening to acoustic models of implant processing, in various conditions. Two initial experiments were undertaken to develop and refine an acoustic model of the Nucleus 24 cochlear implant. Findings from these two experiments informed the design of the main acoustic model experiment, which was undertaken in parallel with a further experiment involving users of the Nucleus 24 device. In both experiments, subjects listened to nonsense syllables with and without the addition of stationary background noise, in three different configurations of implant processing parameters. Additionally, in the acoustic model experiment, a simulation of cross-channel spread of excitation, or “channel interaction”, was varied. Results showed that acoustic model experiments were predictive of the pattern of consonant feature transmission in cochlear implant users with better baseline consonant recognition scores. Deficits in consonant recognition in this subgroup could be explained by the loss of phonemically relevant acoustic information in speech due to the nature of cochlear implant processing, while channel interaction appeared to play a smaller role in accounting for problems in consonant recognition. The work also evaluated the effect of changes in channel number and stimulation rate and failed to find any changes in consonant recognition as these parameters were varied. The lack of a stimulation rate effect was consistent with acoustic measurements of the temporal modulation transfer function of the processor, which showed almost no change across stimulation rates.","abstract_has_math":false,"creators":["Verschuur, Carl"],"institution":"University of Southampton","degree_name":"Ph.D.","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007-03","date_published":"2007-03","updated_at":"2026-11-19T09:29:39Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://eprints.soton.ac.uk/id/eprint/51152/1/P2365.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://eprints.soton.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.soton.ac.uk%3A51152","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Verschuur, Carl"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2007-03"]},{"key":"dc:date.issued","label":"Date","values":["2007-03"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Human Sciences Group (pre 2018 reorg)","Institute of Sound and Vibration Research"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Southampton"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://eprints.soton.ac.uk/id/eprint/51152/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["Abbas PJ, Hughes ML, Brown CJ, Miller CA, South H (2004) Channel interaction in cochlear implant users evaluated using the electrically evoked compound action potential. Audiol Neurootol 9: 203-213 Anderson I, Weichbold V, D'Haese P (2002) Recent results with the MED-EL COMBI 40+ cochlear implant and TEMPO+ behind-the-ear processor. Ear Nose Throat J 81: 229-233 Bench J, Kowal A, Bamford J (1979) The BKB (Bamford-Kowal-Bench) sentence lists for partially-hearing children. Br J Audiol 13: 108-112 Black RC, Clark GM (1980) Differential electrical excitation of the auditory nerve. J Acoust Soc Am 67: 868-874 Blamey PJ (2005) Adaptive dynamic range optimization (ADRO): a digital amplification strategy for hearing aids and cochlear implants. Trends Amplif 9: 77-98 Blamey PJ, Dooley GJ (1993) Pattern recognition and masking in cochlear implant patients. Prog Brain Res 97: 271-278 Blamey PJ, Martin LF, Clark GM (1985) A comparison of three speech coding strategies using an acoustic model of a cochlear implant. J Acoust Soc Am 77: 209- 217 Boersma P, Weenink D (2005):Praat: doing phonetics by computer (Version 4.4) [Computer program].http://www.praat.org/ Boex C, de Balthasar C, Kos MI, Pelizzone M (2003a) Electrical field interactions in different cochlear implant systems. J Acoust Soc Am 114: 2049-2057 Boex C, Kos MI, Pelizzone M (2003b) Forward masking in different cochlear implant systems. J Acoust Soc Am 114: 2058-2065 Boex C, Pelizzone M, Montandon P (1996) Speech recognition with a CIS strategy for the ineraid multichannel cochlear implant. Am J Otol 17: 61-68 210 Bonnet RM, Frijns JH, Peeters S, Briaire JJ (2004) Speech recognition with a cochlear implant using triphasic charge-balanced pulses. Acta Otolaryngol 124: 371-375 Brill SM, Gstottner W, Helms J, von Ilberg C, Baumgartner W, Muller J, Kiefer J (1997) Optimization of channel number and stimulation rate for the fast continuous interleaved sampling strategy in the COMBI 40+. Am J Otol 18: S104-S106 Busby PA, Clark GM (1997) Pitch and loudness estimation for single and multiple pulse per period electric pulse rates by cochlear implant patients. J Acoust Soc Am 101: 1687-1695 Busby PA, Tong YC, Clark GM (1993) The perception of temporal modulations by cochlear implant patients. J Acoust Soc Am 94: 124-131 Busby PA, Whitford LA, Blamey PJ, Richardson LM, Clark GM (1994) Pitch perception for different modes of stimulation using the cochlear multiple-electrode prosthesis. J Acoust Soc Am 95: 2658-2669 Carlyon RP, Deeks JM (2002) Limitations on rate discrimination. J Acoust Soc Am 112: 1009-1025 Carlyon RP, van Wieringen A, Long CJ, Deeks JM, Wouters J (2002) Temporal pitch mechanisms in acoustic and electric hearing. J Acoust Soc Am 112: 621-633 Cazals Y, Pelizzone M, Kasper A, Montandon P (1991) Indication of a relation between speech perception and temporal resolution for cochlear implantees. Ann Otol Rhinol Laryngol 100: 893-895 Chatterjee M, Oba SI (2004) Across- and within-channel envelope interactions in cochlear implant listeners. J Assoc Res Otolaryngol 5: 360-375 Chatterjee M, Shannon RV (1998) Forward masked excitation patterns in multielectrode electrical stimulation. J Acoust Soc Am 103: 2565-2572 Childers DG, Wong CF (1994) Measuring and modeling vocal source-tract interaction. IEEE Trans Biomed Eng 41: 663-671 211 Chomsky N and Halle M (1968) The sound patterns of English. New York: Harper and Row Cochlear Ltd. (2002) Nucleus Implant Communicatior (NIC) system overview. N95291 Iss.1, Cochlear Ltd. Cohen LT, Lenarz T, Battmer RD, Bender vS, Busby PA, Cowan RS (2005) A psychophysical forward masking comparison of longitudinal spread of neural excitation in the Contour and straight Nucleus electrode arrays. Int J Audiol 44: 559- 566 Cohen LT, Richardson LM, Saunders E, Cowan RS (2003) Spatial spread of neural excitation in cochlear implant recipients: comparison of improved ECAP method and psychophysical forward masking. Hear Res 179: 72-87 Cohen LT, Saunders E, Clark GM (2001) Psychophysics of a prototype peri-modiolar cochlear implant electrode array. Hear Res 155: 63-81 Cohen LT, Saunders E, Richardson LM (2004) Spatial spread of neural excitation: comparison of compound action potential and forward-masking data in cochlear implant recipients. Int J Audiol 43: 346-355 Davis M, Taylor K, Johnsrude I, Carlyon B (2004) How do cochlear implant users learng to understand speech? Transfer of learning between different carriers with vocoded speech. Poster presented at British Society of Audiology Experimental Short Papers Meeting, London, September 2004 Dawson PW, McKay CM, Busby PA, Grayden DB, Clark GM (2000) Electrode discrimination and speech perception in young children using cochlear implants. Ear Hear 21: 597-607 de Balthasar C, Boex C, Cosendai G, Valentini G, Sigrist A, Pelizzone M (2003) Channel interactions with high-rate biphasic electrical stimulation in cochlear implant subjects. Hear Res 182: 77-87 Deeks JM, Carlyon RP (2004) Simulations of cochlear implant hearing using filtered harmonic complexes: implications for concurrent sound segregation. J Acoust Soc Am 115: 1736-1746 Diller N, Battmer RD, Doring WH, Muller-Deile J (1995) Multicentric field evaluation of a new speech coding strategy for cochlear implants. Audiology 34:145- 149 Donaldson GS, Nelson DA (2000) Place-pitch sensitivity and its relation to consonant recognition by cochlear implant listeners using the MPEAK and SPEAK speech processing strategies. J Acoust Soc Am 107: 1645-1658 Dorman MF (1995) Test of the use of amplitude envelope cues to consonant identity by patients who use the Ineraid cochlear implant. Ann Otol Rhinol Laryngol Suppl 166: 223-224 Dorman MF, Dankowski K, McCandless G, Parkin JL, Smith L (1991) Vowel and consonant recognition with the aid of a multichannel cochlear implant. Q J Exp Psychol A 43: 585-601 Dorman MF, Loizou PC (1997) Speech intelligibility as a function of the number of channels of stimulation for normal-hearing listeners and patients with cochlear implants. Am J Otol 18: S113-S114 Dorman MF, Loizou PC (1998) The identification of consonants and vowels by cochlear implant patients using a 6-channel continuous interleaved sampling processor and by normal-hearing subjects using simulations of processors with two to nine channels. Ear Hear 19: 162-166 Dorman MF, Loizou PC, Fitzke J (1998a) The identification of speech in noise by cochlear implant patients and normal-hearing listeners using 6-channel signal processors. Ear Hear 19: 481-484 Dorman MF, Loizou PC, Fitzke J, Tu Z (1998b) The recognition of sentences in noise by normal-hearing listeners using simulations of cochlear-implant signal processors with 6-20 channels. J Acoust Soc Am 104: 3583-3585 213 Dorman MF, Loizou PC, Kemp LL, Kirk KI (2000) Word recognition by children listening to speech processed into a small number of channels: data from normalhearing children and children with cochlear implants. Ear Hear 21: 590-596 Dorman MF, Loizou PC, Rainey D (1997a) Simulating the effect of cochlear-implant electrode insertion depth on speech understanding. J Acoust Soc Am 102: 2993-2996 Dorman MF, Loizou PC, Rainey D (1997b) Speech intelligibility as a function of the number of channels of stimulation for signal processors using sine-wave and noiseband outputs. J Acoust Soc Am 102: 2403-2411 Dorman MF, Loizou PC, Spahr AJ, Maloff E (2002) A comparison of the speech understanding provided by acoustic models of fixed-channel and channel-picking signal processors for cochlear implants. J Speech Lang Hear Res 45: 783-788 Dorman MF, Soli S, Dankowski K, Smith LM, McCandless G, Parkin J (1990) Acoustic cues for consonant identification by patients who use the Ineraid cochlear implant. J Acoust Soc Am 88: 2074-2079 Dudley, H (1939) The vocoder. Bell Labs Record 17:122-26 Fant G. (1970) Acoustic Theory of Speech Production. Mouton, The Hague Faulkner A (2006) Adaptation to distorted frequency-to-place maps: implications of simulations in normal listeners for cochlear implants and electroacoustic stimulation. Audiol Neurootol 11 Suppl 1: 21-26 Faulkner A, Darling, AM, Rosen S, Huckvale M (1995) Modelling cue interaction in the perception of the voiceless fricative/affricate contrast. Lang Cog Proc 10: 369-375 Faulkner A, Rosen S, Smith C (2000) Effects of the salience of pitch and periodicity information on the intelligibility of four-channel vocoded speech: implications for cochlear implants. J Acoust Soc Am 108: 1877-1887 Faulkner A, Rosen S, Stanton D (2003) Simulations of tonotopically mapped speech processors for cochlear implant electrodes varying in insertion depth. J Acoust Soc Am 113: 1073-1080 Faulkner A, Rosen S, Wilkinson L (2001) Effects of the number of channels and speech-to-noise ratio on rate of connected discourse tracking through a simulated cochlear implant speech processor. Ear Hear 22: 431-438 Favre E, Pelizzone M (1993) Channel interactions in patients using the Ineraid multichannel cochlear implant. Hear Res 66: 150-156 Fetterman BL, Domico EH (2002) Speech recognition in background noise of cochlear implant patients. Otolaryngol Head Neck Surg 126: 257-263 Friesen LM, Shannon RV, Baskent D, Wang X (2001) Speech recognition in noise as a function of the number of spectral channels: comparison of acoustic hearing and cochlear implants. J Acoust Soc Am 110: 1150-1163 Friesen LM, Shannon RV, Slattery WH, III (1999) The effect of frequency allocation on phoneme recognition with the nucleus 22 cochlear implant. Am J Otol 20: 729-734 Fu QJ (2002) Temporal processing and speech recognition in cochlear implants. Neuroreport 13: 1635-1639 Fu QJ, Nogaki G (2005) Noise susceptibility of cochlear implant users: the role of spectral resolution and smearing. J Assoc Res Otolaryngol 6: 19-27 Fu QJ, Shannon RV (2000a) Effect of stimulation rate on phoneme recognition by nucleus-22 cochlear implant listeners. J Acoust Soc Am 107: 589-597 Fu QJ, Shannon RV (2000b) Effects of dynamic range and amplitude mapping on phoneme recognition in Nucleus-22 cochlear implant users. Ear Hear 21: 227-235 Fu QJ, Shannon RV, Wang X (1998) Effects of noise and spectral resolution on vowel and consonant recognition: acoustic and electric hearing. J Acoust Soc Am 104: 3586- 3596 Galvin JJ, III, Fu QJ (2005) Effects of stimulation rate, mode and level on modulation detection by cochlear implant users. J Assoc Res Otolaryngol 6: 269-279 Geurts L, Wouters J (1999) Enhancing the speech envelope of continuous interleaved sampling processors for cochlear implants. J Acoust Soc Am 105: 2476-2484 215 Goedegebure A, Goedegebure-Hulshof M, Verschuure H, Dreschler WA (2002) The effects of phonemic compression and anti-upward-spread-of-masking (anti-USOM) on the perception of articulatory features in hearing-impaired listeners. Int J Audiol 41: 414-428 Gonzalez J, Oliver JC (2005) Gender and speaker identification as a function of the number of channels in spectrally reduced speech. J Acoust Soc Am 118: 461-470 Green T, Faulkner A, Rosen S (2004) Enhancing temporal cues to voice pitch in continuous interleaved sampling cochlear implants. J Acoust Soc Am 116: 2298-2310 Green T, Faulkner A, Rosen S, Macherey O (2005) Enhancement of temporal periodicity cues in cochlear implants: effects on prosodic perception and vowel identification. J Acoust Soc Am 118: 375-385 Greenwood DD (1990) A cochlear frequency-position function for several species--29 years later. J Acoust Soc Am 87: 2592-2605 Henry BA, Turner CW (2003) The resolution of complex spectral patterns by cochlear implant and normal-hearing listeners. J Acoust Soc Am 113: 2861-2873 Hescot F, Lorenzi C, Debruille X, Camus JF (2000) Measurement of the temporalmodulation transfer function for a single listener with cochlear hearing loss and lefthemisphere damage. Br J Audiol 34: 341-351 Holden LK, Skinner MW, Holden TA, Demorest ME (2002) Effects of stimulation rate with the Nucleus 24 ACE speech coding strategy. Ear Hear 23: 463-476 Holden-Pitt LD, Hazan V, Revoile SG, Edward DM, Droge J (1995) Temporal and spectral cue use for initial plosive voicing perception by hearing-impaired children and normal-hearing children and adults. Eur J Disord Commun 30: 417-434 Howell D (2003) Fundamental Statistics for the Behavioral Sciences. Brooks Cole Jiang J, Chen M, Alwan A (2006) On the perception of voicing in syllable-initial plosives in noise. J Acoust Soc Am 119: 1092-1105 216 Ketten DR, Skinner MW, Wang G, Vannier MW, Gates GA, Neely JG (1998) In vivo measures of cochlear length and insertion depth of nucleus cochlear implant electrode arrays. Ann Otol Rhinol Laryngol Suppl 175: 1-16 Kohlrausch A, Fassel R, Dau T (2000) The influence of carrier level and frequency on modulation and beat-detection thresholds for sinusoidal carriers. J Acoust Soc Am 108: 723-734 Kral A, Hartmann R, Mortazavi D, Klinke R (1998) Spatial resolution of cochlear implants: the electrical field and excitation of auditory afferents. Hear Res 121: 11-28 Lai WK, Bogli H, Dillier N (2003) A software tool for analyzing multichannel cochlear implant signals. Ear Hear 24: 380-391 Laneau J, Moonen M, Wouters J (2006) Factors affecting the use of noise-band vocoders as acoustic models for pitch perception in cochlear implants. J Acoust Soc Am 119: 491-506 Laneau J, Wouters J, Moonen M (2004) Relative contributions of temporal and place pitch cues to fundamental frequency discrimination in cochlear implantees. J Acoust Soc Am 116: 3606-3619 Lawson DT, Wilson BS, Finley CC (1993) New processing strategies for multichannel cochlear prostheses. Prog Brain Res 97: 313-321 Lieberman P and Blumstein SE (1988) Speech physiology, speech perception and acoustic phonetics. Cambridge: Cambridge University Press Liberman AM, Cooper FS, Shankweiler DP, Studdert-Kennedy M (1967) Perception of the speech code. Psychol Rev 74: 431-461 Liberman AM, Delattre PC, Gerstman LJ, Cooper FS (1956) Tempo of frequency changes as a cue for distinguishing classes of speech sounds. J Exp Psychol 52: 127- 137 Lim HH, Tong YC, Clark GM (1989) Forward masking patterns produced by intracochlear electrical stimulation of one and two electrode pairs in the human cochlea. J Acoust Soc 86: 971-980 217 Loizou PC (1999) Signal-processing techniques for cochlear implants. IEEE Eng Med Biol Mag 18: 34-46 Loizou PC, Dorman M, Tu Z (1999) On the number of channels needed to understand speech. J Acoust Soc Am 106: 2097-2103 Loizou PC, Dorman MF, Tu Z, Fitzke J (2000a) Recognition of sentences in noise by normal-hearing listeners using simulations of speak-type cochlear implant signal processors. Ann Otol Rhinol Laryngol Suppl 185: 67-68 Loizou PC, Poroy O (2001) Minimum spectral contrast needed for vowel identification by normal hearing and cochlear implant listeners. J Acoust Soc Am 110: 1619-1627 Loizou PC, Poroy O, Dorman M (2000b) The effect of parametric variations of cochlear implant processors on speech understanding. J Acoust Soc Am 108: 790-802 Loizou PC, Stickney G, Mishra L, Assmann P (2003) Comparison of speech processing strategies used in the Clarion implant processor. Ear Hear 24: 12-19 Loizou PC (2006) Speech processing in vocoder-centric cochlear implants. Adv Otorhinolaryngol 64: 109-143 Malecot A Acoustic cues for nasal consonants. Lang 32: 274-278 Matsuoka AJ, Rubinstein JT, Abbas PJ, Miller CA (2001) The effects of interpulse interval on stochastic properties of electrical stimulation: models and measurements. IEEE Trans Biomed Eng 48: 416-424 McKay CM, Henshall KR, Hull AE (2005) The effect of rate of stimulation on perception of spectral shape by cochlear implantees. J Acoust Soc Am 118: 386-392 Meyer TA, Frisch SA, Pisoni DB, Miyamoto RT, Svirsky MA (2003) Modeling openset spoken word recognition in postlingually deafened adults after cochlear implantation: some preliminary results with the neighborhood activation model. Otol Neurotol 24: 612-620 218 Miller GA and Nicely PE (1955) An analysis of perceptual confusions among some English consonants. J Acoust Soc Am 27: 338-352 Moore BC (1996) Perceptual consequences of cochlear hearing loss and their implications for the design of hearing aids. Ear Hear 17: 133-161 Moore BC, Glasberg BR (2001) Temporal modulation transfer functions obtained using sinusoidal carriers with normally hearing and hearing-impaired listeners. J Acoust Soc Am 110:"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://eprints.soton.ac.uk/id/eprint/51152/1/P2365.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Normal-hearing adults have no difficulty in recognising consonants accurately, even in moderately adverse listening conditions. By contrast, users of multichannel cochlear implants have difficulty with the accurate perception of consonants, even in good listening conditions. Cochlear implant users are known to show systematic deficits in recognition of consonant features, with perception of the place feature, which relies on spectral information, being worst. These deficits may be attributed both to signal distortions introduced by the processing of the implants and to other factors, in particular the spectrotemporal distortions which occur at the interface between electrode array and auditory nervous system, including cross-channel interaction. The objective of the work reported here was to attempt to partial out the relative contribution of these different factors to consonant recognition. This was achieved by comparing cochlear implant users’ perceptual errors, analysed in terms of information transmission, with errors made by normal-hearing subjects listening to acoustic models of implant processing, in various conditions. Two initial experiments were undertaken to develop and refine an acoustic model of the Nucleus 24 cochlear implant. Findings from these two experiments informed the design of the main acoustic model experiment, which was undertaken in parallel with a further experiment involving users of the Nucleus 24 device. In both experiments, subjects listened to nonsense syllables with and without the addition of stationary background noise, in three different configurations of implant processing parameters. Additionally, in the acoustic model experiment, a simulation of cross-channel spread of excitation, or “channel interaction”, was varied. Results showed that acoustic model experiments were predictive of the pattern of consonant feature transmission in cochlear implant users with better baseline consonant recognition scores. Deficits in consonant recognition in this subgroup could be explained by the loss of phonemically relevant acoustic information in speech due to the nature of cochlear implant processing, while channel interaction appeared to play a smaller role in accounting for problems in consonant recognition. The work also evaluated the effect of changes in channel number and stimulation rate and failed to find any changes in consonant recognition as these parameters were varied. The lack of a stimulation rate effect was consistent with acoustic measurements of the temporal modulation transfer function of the processor, which showed almost no change across stimulation rates."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Acoustic models of consonant recognition in cochlear implant users"]}]}],"canonical_facts":{"dc:creator":["Verschuur, Carl"],"dc:date":["2007-03"],"dc:date.issued":["2007-03"],"dc:description.abstract":["Normal-hearing adults have no difficulty in recognising consonants accurately, even in moderately adverse listening conditions. By contrast, users of multichannel cochlear implants have difficulty with the accurate perception of consonants, even in good listening conditions. Cochlear implant users are known to show systematic deficits in recognition of consonant features, with perception of the place feature, which relies on spectral information, being worst. These deficits may be attributed both to signal distortions introduced by the processing of the implants and to other factors, in particular the spectrotemporal distortions which occur at the interface between electrode array and auditory nervous system, including cross-channel interaction. The objective of the work reported here was to attempt to partial out the relative contribution of these different factors to consonant recognition. This was achieved by comparing cochlear implant users’ perceptual errors, analysed in terms of information transmission, with errors made by normal-hearing subjects listening to acoustic models of implant processing, in various conditions. Two initial experiments were undertaken to develop and refine an acoustic model of the Nucleus 24 cochlear implant. Findings from these two experiments informed the design of the main acoustic model experiment, which was undertaken in parallel with a further experiment involving users of the Nucleus 24 device. In both experiments, subjects listened to nonsense syllables with and without the addition of stationary background noise, in three different configurations of implant processing parameters. Additionally, in the acoustic model experiment, a simulation of cross-channel spread of excitation, or “channel interaction”, was varied. Results showed that acoustic model experiments were predictive of the pattern of consonant feature transmission in cochlear implant users with better baseline consonant recognition scores. Deficits in consonant recognition in this subgroup could be explained by the loss of phonemically relevant acoustic information in speech due to the nature of cochlear implant processing, while channel interaction appeared to play a smaller role in accounting for problems in consonant recognition. The work also evaluated the effect of changes in channel number and stimulation rate and failed to find any changes in consonant recognition as these parameters were varied. The lack of a stimulation rate effect was consistent with acoustic measurements of the temporal modulation transfer function of the processor, which showed almost no change across stimulation rates."],"dc:format":["text"],"dc:identifier.uri":["https://eprints.soton.ac.uk/id/eprint/51152/1/P2365.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["Human Sciences Group (pre 2018 reorg)","Institute of Sound and Vibration Research"],"dc:publisher.institution":["University of Southampton"],"dc:relation.isreferencedby":["https://eprints.soton.ac.uk/id/eprint/51152/"],"dc:relation.references":["Abbas PJ, Hughes ML, Brown CJ, Miller CA, South H (2004) Channel interaction in cochlear implant users evaluated using the electrically evoked compound action potential. Audiol Neurootol 9: 203-213 Anderson I, Weichbold V, D'Haese P (2002) Recent results with the MED-EL COMBI 40+ cochlear implant and TEMPO+ behind-the-ear processor. Ear Nose Throat J 81: 229-233 Bench J, Kowal A, Bamford J (1979) The BKB (Bamford-Kowal-Bench) sentence lists for partially-hearing children. Br J Audiol 13: 108-112 Black RC, Clark GM (1980) Differential electrical excitation of the auditory nerve. J Acoust Soc Am 67: 868-874 Blamey PJ (2005) Adaptive dynamic range optimization (ADRO): a digital amplification strategy for hearing aids and cochlear implants. Trends Amplif 9: 77-98 Blamey PJ, Dooley GJ (1993) Pattern recognition and masking in cochlear implant patients. Prog Brain Res 97: 271-278 Blamey PJ, Martin LF, Clark GM (1985) A comparison of three speech coding strategies using an acoustic model of a cochlear implant. J Acoust Soc Am 77: 209- 217 Boersma P, Weenink D (2005):Praat: doing phonetics by computer (Version 4.4) [Computer program].http://www.praat.org/ Boex C, de Balthasar C, Kos MI, Pelizzone M (2003a) Electrical field interactions in different cochlear implant systems. J Acoust Soc Am 114: 2049-2057 Boex C, Kos MI, Pelizzone M (2003b) Forward masking in different cochlear implant systems. J Acoust Soc Am 114: 2058-2065 Boex C, Pelizzone M, Montandon P (1996) Speech recognition with a CIS strategy for the ineraid multichannel cochlear implant. Am J Otol 17: 61-68 210 Bonnet RM, Frijns JH, Peeters S, Briaire JJ (2004) Speech recognition with a cochlear implant using triphasic charge-balanced pulses. Acta Otolaryngol 124: 371-375 Brill SM, Gstottner W, Helms J, von Ilberg C, Baumgartner W, Muller J, Kiefer J (1997) Optimization of channel number and stimulation rate for the fast continuous interleaved sampling strategy in the COMBI 40+. Am J Otol 18: S104-S106 Busby PA, Clark GM (1997) Pitch and loudness estimation for single and multiple pulse per period electric pulse rates by cochlear implant patients. J Acoust Soc Am 101: 1687-1695 Busby PA, Tong YC, Clark GM (1993) The perception of temporal modulations by cochlear implant patients. J Acoust Soc Am 94: 124-131 Busby PA, Whitford LA, Blamey PJ, Richardson LM, Clark GM (1994) Pitch perception for different modes of stimulation using the cochlear multiple-electrode prosthesis. J Acoust Soc Am 95: 2658-2669 Carlyon RP, Deeks JM (2002) Limitations on rate discrimination. J Acoust Soc Am 112: 1009-1025 Carlyon RP, van Wieringen A, Long CJ, Deeks JM, Wouters J (2002) Temporal pitch mechanisms in acoustic and electric hearing. J Acoust Soc Am 112: 621-633 Cazals Y, Pelizzone M, Kasper A, Montandon P (1991) Indication of a relation between speech perception and temporal resolution for cochlear implantees. Ann Otol Rhinol Laryngol 100: 893-895 Chatterjee M, Oba SI (2004) Across- and within-channel envelope interactions in cochlear implant listeners. J Assoc Res Otolaryngol 5: 360-375 Chatterjee M, Shannon RV (1998) Forward masked excitation patterns in multielectrode electrical stimulation. J Acoust Soc Am 103: 2565-2572 Childers DG, Wong CF (1994) Measuring and modeling vocal source-tract interaction. IEEE Trans Biomed Eng 41: 663-671 211 Chomsky N and Halle M (1968) The sound patterns of English. New York: Harper and Row Cochlear Ltd. (2002) Nucleus Implant Communicatior (NIC) system overview. N95291 Iss.1, Cochlear Ltd. Cohen LT, Lenarz T, Battmer RD, Bender vS, Busby PA, Cowan RS (2005) A psychophysical forward masking comparison of longitudinal spread of neural excitation in the Contour and straight Nucleus electrode arrays. Int J Audiol 44: 559- 566 Cohen LT, Richardson LM, Saunders E, Cowan RS (2003) Spatial spread of neural excitation in cochlear implant recipients: comparison of improved ECAP method and psychophysical forward masking. Hear Res 179: 72-87 Cohen LT, Saunders E, Clark GM (2001) Psychophysics of a prototype peri-modiolar cochlear implant electrode array. Hear Res 155: 63-81 Cohen LT, Saunders E, Richardson LM (2004) Spatial spread of neural excitation: comparison of compound action potential and forward-masking data in cochlear implant recipients. Int J Audiol 43: 346-355 Davis M, Taylor K, Johnsrude I, Carlyon B (2004) How do cochlear implant users learng to understand speech? Transfer of learning between different carriers with vocoded speech. Poster presented at British Society of Audiology Experimental Short Papers Meeting, London, September 2004 Dawson PW, McKay CM, Busby PA, Grayden DB, Clark GM (2000) Electrode discrimination and speech perception in young children using cochlear implants. Ear Hear 21: 597-607 de Balthasar C, Boex C, Cosendai G, Valentini G, Sigrist A, Pelizzone M (2003) Channel interactions with high-rate biphasic electrical stimulation in cochlear implant subjects. Hear Res 182: 77-87 Deeks JM, Carlyon RP (2004) Simulations of cochlear implant hearing using filtered harmonic complexes: implications for concurrent sound segregation. J Acoust Soc Am 115: 1736-1746 Diller N, Battmer RD, Doring WH, Muller-Deile J (1995) Multicentric field evaluation of a new speech coding strategy for cochlear implants. Audiology 34:145- 149 Donaldson GS, Nelson DA (2000) Place-pitch sensitivity and its relation to consonant recognition by cochlear implant listeners using the MPEAK and SPEAK speech processing strategies. J Acoust Soc Am 107: 1645-1658 Dorman MF (1995) Test of the use of amplitude envelope cues to consonant identity by patients who use the Ineraid cochlear implant. Ann Otol Rhinol Laryngol Suppl 166: 223-224 Dorman MF, Dankowski K, McCandless G, Parkin JL, Smith L (1991) Vowel and consonant recognition with the aid of a multichannel cochlear implant. Q J Exp Psychol A 43: 585-601 Dorman MF, Loizou PC (1997) Speech intelligibility as a function of the number of channels of stimulation for normal-hearing listeners and patients with cochlear implants. Am J Otol 18: S113-S114 Dorman MF, Loizou PC (1998) The identification of consonants and vowels by cochlear implant patients using a 6-channel continuous interleaved sampling processor and by normal-hearing subjects using simulations of processors with two to nine channels. Ear Hear 19: 162-166 Dorman MF, Loizou PC, Fitzke J (1998a) The identification of speech in noise by cochlear implant patients and normal-hearing listeners using 6-channel signal processors. Ear Hear 19: 481-484 Dorman MF, Loizou PC, Fitzke J, Tu Z (1998b) The recognition of sentences in noise by normal-hearing listeners using simulations of cochlear-implant signal processors with 6-20 channels. J Acoust Soc Am 104: 3583-3585 213 Dorman MF, Loizou PC, Kemp LL, Kirk KI (2000) Word recognition by children listening to speech processed into a small number of channels: data from normalhearing children and children with cochlear implants. Ear Hear 21: 590-596 Dorman MF, Loizou PC, Rainey D (1997a) Simulating the effect of cochlear-implant electrode insertion depth on speech understanding. J Acoust Soc Am 102: 2993-2996 Dorman MF, Loizou PC, Rainey D (1997b) Speech intelligibility as a function of the number of channels of stimulation for signal processors using sine-wave and noiseband outputs. J Acoust Soc Am 102: 2403-2411 Dorman MF, Loizou PC, Spahr AJ, Maloff E (2002) A comparison of the speech understanding provided by acoustic models of fixed-channel and channel-picking signal processors for cochlear implants. J Speech Lang Hear Res 45: 783-788 Dorman MF, Soli S, Dankowski K, Smith LM, McCandless G, Parkin J (1990) Acoustic cues for consonant identification by patients who use the Ineraid cochlear implant. J Acoust Soc Am 88: 2074-2079 Dudley, H (1939) The vocoder. Bell Labs Record 17:122-26 Fant G. (1970) Acoustic Theory of Speech Production. Mouton, The Hague Faulkner A (2006) Adaptation to distorted frequency-to-place maps: implications of simulations in normal listeners for cochlear implants and electroacoustic stimulation. Audiol Neurootol 11 Suppl 1: 21-26 Faulkner A, Darling, AM, Rosen S, Huckvale M (1995) Modelling cue interaction in the perception of the voiceless fricative/affricate contrast. Lang Cog Proc 10: 369-375 Faulkner A, Rosen S, Smith C (2000) Effects of the salience of pitch and periodicity information on the intelligibility of four-channel vocoded speech: implications for cochlear implants. J Acoust Soc Am 108: 1877-1887 Faulkner A, Rosen S, Stanton D (2003) Simulations of tonotopically mapped speech processors for cochlear implant electrodes varying in insertion depth. J Acoust Soc Am 113: 1073-1080 Faulkner A, Rosen S, Wilkinson L (2001) Effects of the number of channels and speech-to-noise ratio on rate of connected discourse tracking through a simulated cochlear implant speech processor. Ear Hear 22: 431-438 Favre E, Pelizzone M (1993) Channel interactions in patients using the Ineraid multichannel cochlear implant. Hear Res 66: 150-156 Fetterman BL, Domico EH (2002) Speech recognition in background noise of cochlear implant patients. Otolaryngol Head Neck Surg 126: 257-263 Friesen LM, Shannon RV, Baskent D, Wang X (2001) Speech recognition in noise as a function of the number of spectral channels: comparison of acoustic hearing and cochlear implants. J Acoust Soc Am 110: 1150-1163 Friesen LM, Shannon RV, Slattery WH, III (1999) The effect of frequency allocation on phoneme recognition with the nucleus 22 cochlear implant. Am J Otol 20: 729-734 Fu QJ (2002) Temporal processing and speech recognition in cochlear implants. Neuroreport 13: 1635-1639 Fu QJ, Nogaki G (2005) Noise susceptibility of cochlear implant users: the role of spectral resolution and smearing. J Assoc Res Otolaryngol 6: 19-27 Fu QJ, Shannon RV (2000a) Effect of stimulation rate on phoneme recognition by nucleus-22 cochlear implant listeners. J Acoust Soc Am 107: 589-597 Fu QJ, Shannon RV (2000b) Effects of dynamic range and amplitude mapping on phoneme recognition in Nucleus-22 cochlear implant users. Ear Hear 21: 227-235 Fu QJ, Shannon RV, Wang X (1998) Effects of noise and spectral resolution on vowel and consonant recognition: acoustic and electric hearing. J Acoust Soc Am 104: 3586- 3596 Galvin JJ, III, Fu QJ (2005) Effects of stimulation rate, mode and level on modulation detection by cochlear implant users. J Assoc Res Otolaryngol 6: 269-279 Geurts L, Wouters J (1999) Enhancing the speech envelope of continuous interleaved sampling processors for cochlear implants. J Acoust Soc Am 105: 2476-2484 215 Goedegebure A, Goedegebure-Hulshof M, Verschuure H, Dreschler WA (2002) The effects of phonemic compression and anti-upward-spread-of-masking (anti-USOM) on the perception of articulatory features in hearing-impaired listeners. Int J Audiol 41: 414-428 Gonzalez J, Oliver JC (2005) Gender and speaker identification as a function of the number of channels in spectrally reduced speech. J Acoust Soc Am 118: 461-470 Green T, Faulkner A, Rosen S (2004) Enhancing temporal cues to voice pitch in continuous interleaved sampling cochlear implants. J Acoust Soc Am 116: 2298-2310 Green T, Faulkner A, Rosen S, Macherey O (2005) Enhancement of temporal periodicity cues in cochlear implants: effects on prosodic perception and vowel identification. J Acoust Soc Am 118: 375-385 Greenwood DD (1990) A cochlear frequency-position function for several species--29 years later. J Acoust Soc Am 87: 2592-2605 Henry BA, Turner CW (2003) The resolution of complex spectral patterns by cochlear implant and normal-hearing listeners. J Acoust Soc Am 113: 2861-2873 Hescot F, Lorenzi C, Debruille X, Camus JF (2000) Measurement of the temporalmodulation transfer function for a single listener with cochlear hearing loss and lefthemisphere damage. Br J Audiol 34: 341-351 Holden LK, Skinner MW, Holden TA, Demorest ME (2002) Effects of stimulation rate with the Nucleus 24 ACE speech coding strategy. Ear Hear 23: 463-476 Holden-Pitt LD, Hazan V, Revoile SG, Edward DM, Droge J (1995) Temporal and spectral cue use for initial plosive voicing perception by hearing-impaired children and normal-hearing children and adults. Eur J Disord Commun 30: 417-434 Howell D (2003) Fundamental Statistics for the Behavioral Sciences. Brooks Cole Jiang J, Chen M, Alwan A (2006) On the perception of voicing in syllable-initial plosives in noise. J Acoust Soc Am 119: 1092-1105 216 Ketten DR, Skinner MW, Wang G, Vannier MW, Gates GA, Neely JG (1998) In vivo measures of cochlear length and insertion depth of nucleus cochlear implant electrode arrays. Ann Otol Rhinol Laryngol Suppl 175: 1-16 Kohlrausch A, Fassel R, Dau T (2000) The influence of carrier level and frequency on modulation and beat-detection thresholds for sinusoidal carriers. J Acoust Soc Am 108: 723-734 Kral A, Hartmann R, Mortazavi D, Klinke R (1998) Spatial resolution of cochlear implants: the electrical field and excitation of auditory afferents. Hear Res 121: 11-28 Lai WK, Bogli H, Dillier N (2003) A software tool for analyzing multichannel cochlear implant signals. Ear Hear 24: 380-391 Laneau J, Moonen M, Wouters J (2006) Factors affecting the use of noise-band vocoders as acoustic models for pitch perception in cochlear implants. J Acoust Soc Am 119: 491-506 Laneau J, Wouters J, Moonen M (2004) Relative contributions of temporal and place pitch cues to fundamental frequency discrimination in cochlear implantees. J Acoust Soc Am 116: 3606-3619 Lawson DT, Wilson BS, Finley CC (1993) New processing strategies for multichannel cochlear prostheses. Prog Brain Res 97: 313-321 Lieberman P and Blumstein SE (1988) Speech physiology, speech perception and acoustic phonetics. Cambridge: Cambridge University Press Liberman AM, Cooper FS, Shankweiler DP, Studdert-Kennedy M (1967) Perception of the speech code. Psychol Rev 74: 431-461 Liberman AM, Delattre PC, Gerstman LJ, Cooper FS (1956) Tempo of frequency changes as a cue for distinguishing classes of speech sounds. J Exp Psychol 52: 127- 137 Lim HH, Tong YC, Clark GM (1989) Forward masking patterns produced by intracochlear electrical stimulation of one and two electrode pairs in the human cochlea. J Acoust Soc 86: 971-980 217 Loizou PC (1999) Signal-processing techniques for cochlear implants. IEEE Eng Med Biol Mag 18: 34-46 Loizou PC, Dorman M, Tu Z (1999) On the number of channels needed to understand speech. J Acoust Soc Am 106: 2097-2103 Loizou PC, Dorman MF, Tu Z, Fitzke J (2000a) Recognition of sentences in noise by normal-hearing listeners using simulations of speak-type cochlear implant signal processors. Ann Otol Rhinol Laryngol Suppl 185: 67-68 Loizou PC, Poroy O (2001) Minimum spectral contrast needed for vowel identification by normal hearing and cochlear implant listeners. J Acoust Soc Am 110: 1619-1627 Loizou PC, Poroy O, Dorman M (2000b) The effect of parametric variations of cochlear implant processors on speech understanding. J Acoust Soc Am 108: 790-802 Loizou PC, Stickney G, Mishra L, Assmann P (2003) Comparison of speech processing strategies used in the Clarion implant processor. Ear Hear 24: 12-19 Loizou PC (2006) Speech processing in vocoder-centric cochlear implants. Adv Otorhinolaryngol 64: 109-143 Malecot A Acoustic cues for nasal consonants. Lang 32: 274-278 Matsuoka AJ, Rubinstein JT, Abbas PJ, Miller CA (2001) The effects of interpulse interval on stochastic properties of electrical stimulation: models and measurements. IEEE Trans Biomed Eng 48: 416-424 McKay CM, Henshall KR, Hull AE (2005) The effect of rate of stimulation on perception of spectral shape by cochlear implantees. J Acoust Soc Am 118: 386-392 Meyer TA, Frisch SA, Pisoni DB, Miyamoto RT, Svirsky MA (2003) Modeling openset spoken word recognition in postlingually deafened adults after cochlear implantation: some preliminary results with the neighborhood activation model. Otol Neurotol 24: 612-620 218 Miller GA and Nicely PE (1955) An analysis of perceptual confusions among some English consonants. J Acoust Soc Am 27: 338-352 Moore BC (1996) Perceptual consequences of cochlear hearing loss and their implications for the design of hearing aids. Ear Hear 17: 133-161 Moore BC, Glasberg BR (2001) Temporal modulation transfer functions obtained using sinusoidal carriers with normally hearing and hearing-impaired listeners. J Acoust Soc Am 110:"],"dcterms:accessrights":["public"],"dc:title":["Acoustic models of consonant recognition in cochlear implant users"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D."]},"updated_at":"2026-11-19T09:29:39Z"}