{"id":{"repo_id":"st-cloud","oai_identifier":"oai:repository.stcloudstate.edu:20.500.14755/1228"},"canonical_url":"https://search.ndltd.org/etd/st-cloud/oai:repository.stcloudstate.edu:20.500.14755/1228","repository":{"repo_id":"st-cloud","name":"St. Cloud State University","base_url":"https://repository.stcloudstate.edu/server/oai/request"},"display":{"title":"Very Low Frequency Electrical Impedance Tomography Image Reconstruction System Using FPGA Software-Hardware Co-design","abstract":"Electrical Impedance Tomography (EIT) is an imaging technique which is noninvasive and uses the internal conductivity distribution of the object of interest to form a tomographic image. It is performed by applying electrodes to the surface of the object. An alternating current up to frequency 10kHz is applied through a pair of electrodes, and the induced voltage is measured on other electrodes. These current and voltage values are used to reconstruct the internal conductivity distribution. The EIT imaging is increasingly getting used in clinical applications, as it is safer, portable, and low cost if compared with available imaging technologies used in clinical settings. The goal of this project is to develop a low frequency Zynq SoC-based EIT system. A Zynq 7020 device-based development board, Zedboard, interfaced with a customized hardware circuit, is used to develop a complete EIT system. A graphical user interface is developed using C# Graphic User Interface (GUI) application to control the hardware and visualize the results. It is a twelve-electrode system, and current injection and voltage measurement is performed through Zynq SoC. There are two image reconstruction algorithms developed, Gauss Newton One Step and Total variation. The algorithms are implemented in Zynq SoC using software-hardware co-design. The algorithms are also implemented in C#. The image reconstruction performance between the two algorithms is compared. The computation performance between Zynq SoC implementation and C# implementation is also compared to understand the feasibility of FPGA implementation of EIT image reconstruction algorithms.","abstract_html":"Electrical Impedance Tomography (EIT) is an imaging technique which is noninvasive and uses the internal conductivity distribution of the object of interest to form a tomographic image. It is performed by applying electrodes to the surface of the object. An alternating current up to frequency 10kHz is applied through a pair of electrodes, and the induced voltage is measured on other electrodes. These current and voltage values are used to reconstruct the internal conductivity distribution. The EIT imaging is increasingly getting used in clinical applications, as it is safer, portable, and low cost if compared with available imaging technologies used in clinical settings. The goal of this project is to develop a low frequency Zynq SoC-based EIT system. A Zynq 7020 device-based development board, Zedboard, interfaced with a customized hardware circuit, is used to develop a complete EIT system. A graphical user interface is developed using C# Graphic User Interface (GUI) application to control the hardware and visualize the results. It is a twelve-electrode system, and current injection and voltage measurement is performed through Zynq SoC. There are two image reconstruction algorithms developed, Gauss Newton One Step and Total variation. The algorithms are implemented in Zynq SoC using software-hardware co-design. The algorithms are also implemented in C#. The image reconstruction performance between the two algorithms is compared. The computation performance between Zynq SoC implementation and C# implementation is also compared to understand the feasibility of FPGA implementation of EIT image reconstruction algorithms.","abstract_has_math":false,"creators":["Sinare, Monali"],"institution":null,"degree_name":"Electrical Engineering: M.S.","degree_level":null,"degree_discipline":null,"degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":["Dr. Yi Zheng","Dr. Mahbub Hossain","Dr. Shensheng Tang"],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021-05-01","date_published":"2021-05-01","updated_at":"2026-11-27T09:55:53Z","subjects":["EIT","FPGA","Zynq","C#","Low Frequency"],"languages":[],"rights":[],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ece_etds-5"],"render_values":[{"text":"ece_etds-5","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14755/1228","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14755/1228","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Ast-cloud%3Aoai%3Arepository.stcloudstate.edu%3A20.500.14755%2F1228","prefix":"oai_dc"},"source_record":{"url":"https://repository.stcloudstate.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.stcloudstate.edu%3A20.500.14755%2F1228","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Dr. Yi Zheng","Dr. Mahbub Hossain","Dr. Shensheng Tang"]},{"key":"dc:creator","label":"Author","values":["Sinare, Monali"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-08-17T14:13:50Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-06-12 14:05:18"]},{"key":"dc:date.issued","label":"Date","values":["2021-05-01"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2021-04-09 10:00:23"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["College of Liberal Arts"]},{"key":"thesis:degree_department","label":"Department","values":["Electrical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Electrical Engineering: M.S."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["EIT","FPGA","Zynq","C#","Low Frequency"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Culminating Projects in Electrical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ece_etds-5"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14755/1228"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Electrical Impedance Tomography (EIT) is an imaging technique which is noninvasive and uses the internal conductivity distribution of the object of interest to form a tomographic image. It is performed by applying electrodes to the surface of the object. An alternating current up to frequency 10kHz is applied through a pair of electrodes, and the induced voltage is measured on other electrodes. These current and voltage values are used to reconstruct the internal conductivity distribution. The EIT imaging is increasingly getting used in clinical applications, as it is safer, portable, and low cost if compared with available imaging technologies used in clinical settings. The goal of this project is to develop a low frequency Zynq SoC-based EIT system. A Zynq 7020 device-based development board, Zedboard, interfaced with a customized hardware circuit, is used to develop a complete EIT system. A graphical user interface is developed using C# Graphic User Interface (GUI) application to control the hardware and visualize the results. It is a twelve-electrode system, and current injection and voltage measurement is performed through Zynq SoC. There are two image reconstruction algorithms developed, Gauss Newton One Step and Total variation. The algorithms are implemented in Zynq SoC using software-hardware co-design. The algorithms are also implemented in C#. The image reconstruction performance between the two algorithms is compared. The computation performance between Zynq SoC implementation and C# implementation is also compared to understand the feasibility of FPGA implementation of EIT image reconstruction algorithms."]},{"key":"dc:format","label":"Dc Format","values":["thesis"]},{"key":"dc:title","label":"Title","values":["Very Low Frequency Electrical Impedance Tomography Image Reconstruction System Using FPGA Software-Hardware Co-design"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Dr. Yi Zheng","Dr. Mahbub Hossain","Dr. Shensheng Tang"],"dc:creator":["Sinare, Monali"],"dc:date.accessioned":["2026-08-17T14:13:50Z"],"dc:date.available":["2021-06-12 14:05:18"],"dc:date.issued":["2021-05-01"],"dc:date.submitted":["2021-04-09 10:00:23"],"dc:description.abstract":["Electrical Impedance Tomography (EIT) is an imaging technique which is noninvasive and uses the internal conductivity distribution of the object of interest to form a tomographic image. It is performed by applying electrodes to the surface of the object. An alternating current up to frequency 10kHz is applied through a pair of electrodes, and the induced voltage is measured on other electrodes. These current and voltage values are used to reconstruct the internal conductivity distribution. The EIT imaging is increasingly getting used in clinical applications, as it is safer, portable, and low cost if compared with available imaging technologies used in clinical settings. The goal of this project is to develop a low frequency Zynq SoC-based EIT system. A Zynq 7020 device-based development board, Zedboard, interfaced with a customized hardware circuit, is used to develop a complete EIT system. A graphical user interface is developed using C# Graphic User Interface (GUI) application to control the hardware and visualize the results. It is a twelve-electrode system, and current injection and voltage measurement is performed through Zynq SoC. There are two image reconstruction algorithms developed, Gauss Newton One Step and Total variation. The algorithms are implemented in Zynq SoC using software-hardware co-design. The algorithms are also implemented in C#. The image reconstruction performance between the two algorithms is compared. The computation performance between Zynq SoC implementation and C# implementation is also compared to understand the feasibility of FPGA implementation of EIT image reconstruction algorithms."],"dc:format":["thesis"],"dc:identifier.other":["ece_etds-5"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14755/1228"],"dc:rights.uri":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"dc:subject":["EIT","FPGA","Zynq","C#","Low Frequency"],"dc:subject.classification":["Culminating Projects in Electrical Engineering"],"dc:title":["Very Low Frequency Electrical Impedance Tomography Image Reconstruction System Using FPGA Software-Hardware Co-design"],"others:access_status":["open.access"],"thesis:degree_college":["College of Liberal Arts"],"thesis:degree_department":["Electrical Engineering"],"thesis:degree_name":["Electrical Engineering: M.S."]},"updated_at":"2026-11-27T09:55:53Z"}